• Title/Summary/Keyword: sampling Method

Search Result 4,914, Processing Time 0.028 seconds

Bootstrap Confidence Intervals for a One Parameter Model using Multinomial Sampling

  • Jeong, Hyeong-Chul;Kim, Dae-Hak
    • Journal of the Korean Data and Information Science Society
    • /
    • v.10 no.2
    • /
    • pp.465-472
    • /
    • 1999
  • We considered a bootstrap method for constructing confidenc intervals for a one parameter model using multinomial sampling. The convergence rates or the proposed bootstrap method are calculated for model-based maximum likelihood estimators(MLE) using multinomial sampling. Monte Carlo simulation was used to compare the performance of bootstrap methods with normal approximations in terms of the average coverage probability criterion.

  • PDF

A Study on Determining of Job Sequence by Work Sampling(I) (W.S법에 의한 JOB SEQUENCE의 결정(I))

  • 강성수;노인규
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.11 no.18
    • /
    • pp.59-69
    • /
    • 1988
  • This study represents the method of application of W.S(Work Sampling) to determine job sequence. The result shows job sequence which has the came performance measure of optimal job sequence is selected by average number of 199 sampling. In the case, the optimal job sequence is not selected within the sampling number of 921 which satisfy the reliability of 99.5% and precision of 99%, the deviation is very little which 0.73%. This improves the possibility of application of W.S method to select optimal job sequence is very high.

  • PDF

Field Validation of a Sampling and Analytical Method Developed for Preventing Airborne Hexavalent Chromium Collected on PVC Filter from Reduction (PVC 여과지에서의 환원 방지를 위해 개발된 공기중 6가 크롬 측정방법의 현장 평가)

  • 신용철;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of airborne hexavalent chromium, Cr(Ⅵ), in a field plating operation. The procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute iota Occupational Safety and Health (NIOSH) Method 7600, and the filler sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(Ⅵ) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(Ⅵ) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(Ⅵ) on PVC filters and storing the sample filters in strew-capped vials according to the NIOSH method, and analyzing Cr(Ⅵ) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(Ⅵ) into 0.02 M NaHCO₃ solution in midget impinger, and analyzing the Cr(Ⅵ) in samples using IC/VS. The third method was the OSHA Method ID-215. Using these four different methods, lour replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r²:0.99) between Cr(Ⅵ) concentrations measured by the Shin & Paik's Method and an impinger method (p>0.05). However, Cr(Ⅵ) concentrations determined by Shin & Paik's Method were significant1y different from those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(Ⅵ) concentrations of Shin & Paik's Method were significantly higher than those of the NIOSH/EPA Method or the OSHA method. This result indicated that the Shin & Paik's Method may prevent Cr(Ⅵ) losses caused by reduction and give more reliable results of airborne Cr(Ⅵ) concentrations in work environments.

Failure Probability Calculation Method Using Kriging Metamodel-based Importance Sampling Method (크리깅 근사모델 기반의 중요도 추출법을 이용한 고장확률 계산 방안)

  • Lee, Seunggyu;Kim, Jae Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.381-389
    • /
    • 2017
  • The kernel density was determined based on sampling points obtained in a Markov chain simulation and was assumed to be an important sampling function. A Kriging metamodel was constructed in more detail in the vicinity of a limit state. The failure probability was calculated based on importance sampling, which was performed for the Kriging metamodel. A pre-existing method was modified to obtain more sampling points for a kernel density in the vicinity of a limit state. A stable numerical method was proposed to find a parameter of the kernel density. To assess the completeness of the Kriging metamodel, the possibility of changes in the calculated failure probability due to the uncertainty of the Kriging metamodel was calculated.

Self-Sampling Versus Physicians' Sampling for Cervical Cancer Screening - Agreement of Cytological Diagnoses

  • Othman, Nor Hayati;Zaki, Fatma Hariati Mohamad;Hussain, Nik Hazlina Nik;Yusoff, Wan Zahanim Wan;Ismail, Pazuddin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3489-3494
    • /
    • 2016
  • Background: A major problem with cervical cancer screening in countries which have no organized national screening program for cervical cancer is sub-optimal participation. Implementation of self-sampling method may increase the coverage. Objective: We determined the agreement of cytological diagnoses made on samples collected by women themselves (self-sampling) versus samples collected by physicians (Physician sampling). Materials and Methods: We invited women volunteers to undergo two procedures; cervical self-sampling using the Evalyn brush and physician sampling using a Cervex brush. The women were shown a video presentation on how to take their own cervical samples before the procedure. The samples taken by physicians were taken as per routine testing (Gold Standard). All samples were subjected to Thin Prep monolayer smears. The diagnoses made were according to the Bethesda classification. The results from these two sampling methods were analysed and compared. Results: A total of 367 women were recruited into the study, ranging from 22 to 65 years age. There was a significant good agreement of the cytological diagnoses made on the samples from the two sampling methods with the Kappa value of 0.568 (p=0.040). Using the cytological smears taken by physicians as the gold standard, the sensitivity of self-sampling was 71.9% (95% CI:70.9-72.8), the specificity was 86.6% (95% CI:85.7-87.5), the positive predictive value was 74.2% (95% CI:73.3-75.1) and the negative predictive value was 85.1% (95% CI: 84.2-86.0). Self-sampling smears (22.9%) allowed detection of micro-organisms better than physicians samples (18.5%). Conclusions: This study shows that samples taken by women themselves (self-sampling) and physicians have good diagnostic agreement. Self-sampling could be the method of choice in countries in which the coverage of women attending clinics for screening for cervical cancer is poor.

Application of Adsorption Sampling and Thermal Desorption with GC/MS Analysis for the Measurement of Low-Molecular Weight PAHs in Ambient Air (환경대기 중 저분자 PAHs 측정을 위한 흡착-열탈착-GC/MS 방법의 적용)

  • Seo, Seok-Jun;Seo, Young-Kyo;Hwang, Yoon-Jung;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.362-377
    • /
    • 2014
  • Polycyclic aromatic hydrocarbons (PAHs) have been of particular concern since they are present both in the vapor and particulate phases in ambient air. In this study, a simple method was applied to determine the vapor phase PAHs, and the performance of the new method was evaluated with a conventional method. The simple method was based on adsorption sampling and thermal desorption with GC/MS analysis, which is generally applied to the determination of volatile organic compounds (VOCs) in the air. A combination of Carbotrap (300 mg) and Carbotrap-C (100 mg) sorbents was used as the adsorbent. Target compounds included two rings PAHs such as naphthalene, acenaphthylene, and acenaphthene. Among them, naphthalene was listed as one of the main HAPs together with a number of VOCs in petroleum refining industries in the USA. For comparison purposes, a method based on adsorption sampling and solvent extraction with GC/MS analysis was adopted, which is in principle same as the NIOSH 5515 method. The performance of the adsorption sampling and thermal desorption method was evaluated with respect to repeatabilities, detection limits, linearities, and storage stabilities for target compounds. The analytical repeatabilities of standard samples are all within 20%. Lower detection limits was estimated to be less than 0.1 ppbv. In the results from comparison studies between two methods for real air samples. Although the correlation coefficients were more than 0.9, a systematic difference between the two groups was revealed by the paired t-test (${\alpha}$=0.05). Concentrations of two-rings PAHs determined by adsorption and thermal desorption method consistently higher than those by solvent extraction method. The difference was caused by not only the poor sampling efficiencies of XAD-2 for target PAHs and but also sample losses during the solvent extraction and concentration procedure. This implies that the levels of lower molecular PAHs tend to be underestimated when determined by a conventional PAH method utilizing XAD-2 (and/or PUF) sampling and solvent extraction method. The adsorption sampling and thermal desorption with GC analysis is very simple, rapid, and reliable for lower-molecular weight PAHs. In addition, the method can be used for the measurement of VOCs in the air simultaneously. Therefore, we recommend that the determination of naphthalene, the most volatile PAH, will be better when it is measured by a VOC method instead of a conventional PAH method from a viewpoint of accuracy.

Design method of interpolation kernel using piecewise $\textit{n}$ th polynomials

  • Honma, Akihiro;Aikawa, Naoyuki
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.694-697
    • /
    • 2002
  • Sampling rate conversion widely used in subband coding, A/D and D/A transitions etc. is an important techniques. Nyquist filters and the filter banks have been used far the sampling converter. However, they need many memories and, whenever the sampling rate is changed it is necessary to redesign filters. Then we propose design method of the new interpolation kernel. Design method of the new interpolation kernel is approximated each piecewise of lowpass filter by n th polynomials. The proposed kernel is not redesigned, whenever the sampling rate is changed. The proposed kernel is a continuous function, the sampling rate of the rational number can be converted.

  • PDF

Study on a Robust Optimization Algorithm Using Latin Hypercube Sampling Experiment and Multiquadric Radial Basis Function (Latin Hypercube Sampling Experiment와 Multiquadric Radial Basis Function을 이용한 최적화 알고리즘에 대한 연구)

  • Zhang, Yanli;Yoon, Hee-Sung;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.162-164
    • /
    • 2007
  • This paper presents a "window-zoom-out" optimization strategy with relatively fewer sampling data. In this method, an optimal Latin hypercube sampling experiment based on multi-objective Pareto optimization is developed to obtain the sampling data. The response surface method with multiquadric radial basis function combined with (1+$\lambda$) evolution strategy is used to find the global optimal point. The proposed method is verified with numerical experiments.

  • PDF

Reliability Estimation Using Kriging Metamodel (크리깅 메타모델을 이용한 신뢰도 계산)

  • Cho Tae-Min;Ju Byeong-Hyeon;Jung Do-Hyun;Lee Byung-Chai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.8 s.251
    • /
    • pp.941-948
    • /
    • 2006
  • In this study, the new method for reliability estimation is proposed using kriging metamodel. Kriging metamodel can be determined by appropriate sampling range and sampling numbers because there are no random errors in the Design and Analysis of Computer Experiments(DACE) model. The first kriging metamodel is made based on widely ranged sampling points. The Advanced First Order Reliability Method(AFORM) is applied to the first kriging metamodel to estimate the reliability approximately. Then, the second kriging metamodel is constructed using additional sampling points with updated sampling range. The Monte-Carlo Simulation(MCS) is applied to the second kriging metamodel to evaluate the reliability. The proposed method is applied to numerical examples and the results are almost equal to the reference reliability.

On inference of multivariate means under ranked set sampling

  • Rochani, Haresh;Linder, Daniel F.;Samawi, Hani;Panchal, Viral
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.1
    • /
    • pp.1-13
    • /
    • 2018
  • In many studies, a researcher attempts to describe a population where units are measured for multiple outcomes, or responses. In this paper, we present an efficient procedure based on ranked set sampling to estimate and perform hypothesis testing on a multivariate mean. The method is based on ranking on an auxiliary covariate, which is assumed to be correlated with the multivariate response, in order to improve the efficiency of the estimation. We showed that the proposed estimators developed under this sampling scheme are unbiased, have smaller variance in the multivariate sense, and are asymptotically Gaussian. We also demonstrated that the efficiency of multivariate regression estimator can be improved by using Ranked set sampling. A bootstrap routine is developed in the statistical software R to perform inference when the sample size is small. We use a simulation study to investigate the performance of the method under known conditions and apply the method to the biomarker data collected in China Health and Nutrition Survey (CHNS 2009) data.