• Title/Summary/Keyword: sample injection method

Search Result 168, Processing Time 0.026 seconds

Precise Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (Indirect force 측정 방법과 Pseudo-역행렬을 이용한 정밀한 Force 예측)

  • 심재술;안병하;하종훈;정현출
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.564-567
    • /
    • 1997
  • In the design of structure the forces acting on the structure are important parameter for noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. Thus it is necessary to find out indirect force evaluation method. In this paper forces have been measured with in-situ vibration responses and system information. Three existing techniques of indirect force measurement, viz. direct inverse, principal component analysis and regularization have been compared. It has been shown that multi-vibration responses are essential for the precise estimation of the forces. To satisfy those conditions, Rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It has also been obtained that relatively higher force is transmitted though three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate and is investigated the possibility of force evaluation of rotary compressor as a complex structure.

  • PDF

Studies on the Spectrophotometric Determination and Electrochemical Behavior of Heavy Lanthanide Ions in Nonaqueous System and Heavy Metal Chelate Complexes with Bidentate Legands: (Part I) Flow Injection Spectrophotometric Determination of Heavy Lanthanide Ions with Xylenol Orange

  • Sam-Woo Kang;Chong-Min Park;Kwang-Hee Cho;Hong-Seock Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.59-62
    • /
    • 1993
  • Spectrophotometric determination of some heavy lanthanide ions by flow injection method is described. Xylenol Orange forms water soluble chelates with lanthanide ions in a tris[hydroxymethyl]-aminomethane-buffered medium having pH 8.3 and containing cetyltrimethylammonium bromide. The molar absorptivities of Ln(III)-XO complexes were increased by the ternary system with cetyltrimethylammonium bromide with the concomitant bathochromic shift of absorption maxium compared to those of the binary system without cetyltrimethylammonium bromide. The calibration curves are linear in the range 0.25-1.00 ppm for Gd(III), Dy(III), Er(III), Tm(III) and Yb(III) and the dynamic range are very wide. The detection limits (S/N=2) are from 2 ppb for Gd(III) to 30 ppb for Yb(III) and the relative standard deviations are from 1.2% for 0.5 ppm Gd(III) to 1.8% for 0.5 ppm Yb(III). The sample throughput was ca. 50 $h^{-1}$.

The Development of Continuous Flow Method Through Microwave Oven for the Analysis of Metal Oxides in Water by ICP-AES (ICP-AES에 의한 수중의 금속 산화물 직접분석을 위한 연속흐름 Microwave 용해장치 개발 연구)

  • Kim, Yeon Du;Lee, Gye Ho;Kim, Hyeong Seung;Kim, Dong Su;Park, Gwang Gyu
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.8
    • /
    • pp.576-584
    • /
    • 1994
  • The method described offers rapid and efficient sample preparation using on-line microwave digestion of metal oxides in water sample with direct elemental detection by ICP-AES. The open tubing digestion system(OTD) and the restraint tubing digestion system(RTD) for flow injection(FI) were designed and tested to find the optimum conditions. Comparison of OTD and RTD indicated that RTD was 3 times faster on the digestion time, and 10 times higher on sample mass. Finally, the results of RTD agree well with those by conventional microwave open vessel in all cases and show good precision; Fe and Cu show good with about 5% of RSD, while Zn and Co more or less than 10% RSD.

  • PDF

Anti-inflammatory Effects of Hongdeung-Tang on Mice with LPS Injected in Vagina (홍등탕(紅藤湯)이 LPS 질내(膣內) 주입(注入) 생쥐에 미치는 항염증(抗炎症)효과)

  • Seo, Ji-Young;Kim, Yoon-Sang;Yun, Jeong-Mun;Lee, Tae-Hui;Lim, Eun-Mee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.18 no.1
    • /
    • pp.81-93
    • /
    • 2005
  • Purpose : There are various oriental medicine therapy of treating Pelvic Inflammatory Disease(PID) in clinics. We made the PID mice model by injection Lipopolysaccharide (LPS) in vagina, and investigate anti-inflammatory effects of Hongdeung-Tang among oral medication, retention enema therapy and herbal-acupuncture treatment. Method : The ICR(20-30g) mice(♀) were used. To examine the occurrence of inflammation, LPS in different concentration was injected into the vagina of the mice, and White Blood Cell(WBC) in blood was counted. To examine anti-inflammatory effects, 6 mice were assigned to each of the normal group, the control group and the sample group. Hongdeung-Tang was medicated in oral and rectal with 1.0g/kg low dose and 3.0g/kg high dose and by herbal acupucture for 5 days, 2 days before LPS injection. After 3days from LPS injection, blood was collected from retro-orbital plexus, and WBC, Interleukin-6(IL-6), Tumor Necrosis Factor-${\alpha}$(TNF-${\alpha}$) in the blood was counted. Result : After LPS injection with each dose, WBC count showed significant increase depending on LPS concentration from $100{\mu}g/kg$, and it was maximized at 3 or 4 days after LPS injection. the Hongdeung-Tang treatment groups, The number of WBC was decreased significantly only in low dose and high dose oral medication, and IL-6 concentration showed significant decrease in oral and rectal medication as well as in herbal acupuncture treatment. TNF-${\alpha}$ concentration was decreased significantly in oral and rectal medication of low dose and high dose. herbal-acupuncture treatment group datas showed reductive tendency. Conclusion : Based on above results, we made the PID mice model by injection LPS in vagina, and demonstrated anti-inflammatory effect of Hongdeung-Tang of oral medication, retention enema therapy and herbal-acupuncture treatment.

  • PDF

Effects of Gamichangbaek-san(Jiaweichangbai-san) on Anti-inflammatory, Analgesic, Anti-febrile Activities and Immune Responses in Carrageenan-induced Arthritic Animals (가미창백산(加味蒼栢散)이 Carrageenan유발 동물모델 관절염의 소염, 진통, 해열 및 면역에 미치는 영향)

  • Han, Young-Gyu;Park, Young-Hoi;Keum, Dong-Ho;Lee, Myeong-jong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.15 no.1
    • /
    • pp.127-141
    • /
    • 2005
  • Objectives : This study was performed to investigate the effects of Gamichangbaek-san(Jiaweichangbai-san) on anti-inflammatory, analgesic, anti-febrile and immune response on the arthritis of carrageenan-induced animals. Methods and Materials : Rats were classified into control and sample groups which are 7 individuals each for the experiments about anti-inflammatory and anti-febrile. Each of the 7 mice were classified into normal, control, sample groups for the analgesic experiments. Gamichangbai-san(Jiaweichangbai-san) was administered to sample group and normal saline was administered to normal and control groups. Arthritis was induced by injection of 1% carrageenan $0.1m{\ell}$ and Gamichangbaek-san(Jiaweichangbai-san) was administered after 30 minutes. The change of edema in Carrageenan-induced Arthritic Rats' Paws was measured after 1 hour and 5 hours from the injection of carraqeenan with Plethysmometer(7150, UGO BASILE, ltaly) by Winter' method. WBC, Lymphocyte and ESR were measured by heart puncture and CD4+ T cell, CD8+ T cell and CD4+/CD8+ T cell ratio were measured from the spleen tissue. Writhing syndrom was measured with Tail flick unit(UGO BASILE, Italy) in the experiments conducted to check the analgesic activity. The temperature of the paws of carrageenan-induced arthritic rats was measured by Laser thermometer. Rectal temperature was measured by Yeast's method in anti-febrile experiments. Immune response was measured by CD4+, CD8+ T cell ratio and CD4+/CD8+ T cell ratio. Results : 1. It was recognized that Gamichangbaek-san(Jiaweichangbai-san) decreased the increase rate of Paw Edema effectively with statistical significance. 2. It was recognized that Gamichangbaek-san(Jiaweichangbai-san) decreased WBC, Lymphocyte and ESR with statistically high significance. 3. It was recognized that Gamichangbaek-san(Jiaweichangbai-san) did not show significant analgesic effect, but the Pressure pain threshold of the paws was increased with statistical significance. 4. It was recognized that Gamichangbaek-san(Jiaweichangbai-san) decreased rectal temperature effectively and had an anti-febrile effect about the febrile of a joint with statistical significance. 5. It was recognized that Gamichangbaek-san(Jiaweichangbai-san) increased CD4+ T cell ratio with statistically high significance and increased CD+8 T cell ratio with statistical non significance but increased CD4+/CD8+ T cell ratio effectively with statistical significance, too. Conclusions : According to the above results, it can be concluded Gamichangbaek-san(Jiaweichangbai-san) showed the treatment effects on the artificial arthritis resulted from carageenan in rats and it is suggested that more interest and study in the security for the clinical use were needed.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Effects of Kami-bangpungtongseong-san Extracts on the Mouse Skin Toxicated by Mercury (가미방풍통성산(加味防風通聖散)이 수은 중독된 마우스의 피부 손상에 미치는 영향)

  • Yang, Joon-Hyoung;Hong, Seong-Ug
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Objective : Mercuric chloride is excreted in the urine and stool. Bangpungtongseong-san(BT) has been used commonly skin disease and has diuresis and excretion effect. This study is aimed to find out effects of Kami- bangpungtongseong-san(KBT) on the skin disease toxicated by mercury. Method : Experiment was conducted with No treated group(Normal group), Mercuric chloride subcutaneous injection group(Control group) and Kami-bangpungtongseong-san-treated group (Sample group). KBT Extracts were delivered orally in 7 days in sample group. We observed epithelial cell hyperplastic, angiogenesis, inflammatory cell infiltration of skin. For the charting the results, image analysis was taken. The result of image analysis was verified significance by Sigmaplot 2000(P<0.05). Result : This study shows an relieving epithelial cell hyperplastic, angiogenesis, inflammatory cell infiltration of exposure skin on mercuric chloride. Conclusion : According to the result of study, we can expect to the effect of KBT extracts' therapeutic action to tissue injuries of the mice' skin on acute mercurial toxication.

Microfluidic Method for Measurement of Blood Viscosity based on Micro PIV (Micro PIV 를 기반한 혈액 점도 측정 기법)

  • Hong, Hyeonji;Jung, Mirim;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.3
    • /
    • pp.14-19
    • /
    • 2017
  • Increase of blood viscosity significantly changes the flow resistance and wall shear stress which are related with cardiovascular diseases. For measurement of blood viscosity, microfluidic method has proposed by monitoring pressure between sample and reference flows in the downstream of a microchannel with two inlets. However, it is difficult to apply this method to unknown flow conditions. To measure blood viscosity under unknown flow conditions, a microfluidic method based on micro particle image velocimetry(PIV) is proposed in this study. Flow rate in the microchannel was estimated by assuming velocity profiles represent mean value along channel depth. To demonstrate the measurement accuracy of flow rate, the flow rates measured at the upstream and downstream of a T-shaped microchannel were compared with injection flow rate. The present results indicate that blood viscosity could be reasonably estimated according to shear rate by measuring the interfacial width and flow rate of blood flow. This method would be useful for understanding the effects of hemorheological features on the cardiovascular diseases.

Selection of Calibration Approaches and Their Impact on the Quantification of Unknown Samples: Case Study on Reduced Sulfur Gases (환원황화합물의 분석과 검량기준의 선택에 따른 오차발생의 특성)

  • Jo, Hyo-Jae;Hong, One-Feel;Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.133-141
    • /
    • 2011
  • In this study, different calibration approaches for reduced sulfur compounds (RSCs) were investigated by using thermal desorption coupled with gas chromatography (GC) and pulsed flame photometric detection (PFPD). To evaluate the effects of calibration procedures, gaseous standards of 4 RSCs ($H_2S$, $CH_3SH$, DMS, and DMDS) prepared at 10 ppm level were analyzed at 7 loading injection volumes (40, 60, 80, 100, 160, 240, and 320 ${\mu}L$). The results were then compared with calibration curves made with the Z (zero offset) and N (non-zero offset) method. The concentrations of unknown samples were then quantified by using R (ratio) method in which the slope values are compared between standards and samples. Secondly, in A (average) method, results obtained from a multi-point analysis of unknown samples were also averaged to extract representative values for each sample. Results of both experiments showed that analytical error of low molecular weight components (such as $H_2S$ and $CH_3SH$) was greatly expanded with the Z method. In conclusion, the combined application of N-A method was the more realistic approach to reduce biases in the quantification of RSCs.

Novel Scanning Tunneling Spectroscopy for Volatile Adborbates

  • Choi, Eun-Yeoung;Lee, Youn-Joo;Lyo, In-Whan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.58-58
    • /
    • 2010
  • Reactive or unstable adsorbates are often difficult to study spectroscopically. They may have, for instance, resonance states lying close to the Fermi level, inducing them to desorb or decompose by the probe itself, low-energy tunneling electrons. In order to overcome this limitation, we developed a novel method, which we call x-ramp scan. The method sweeps the bias voltage, with the simutaneous scan along the imaging direction, in a constant current mode. This mapping yields the tip-height variation as a function of bias, or Z(V), at nominally always fresh surface. We applied this method to the investigation of methanol-induced molecular features, attributed to methoxy, found on NiAl(110) surface. These were produced by methanol molecules deposited by a pulse injection method onto the metallic surface. Our study shows adsorbed methoxy are very reactive to the bias voltage, rendering the standard spectroscopy useless. Our new x-ramp scan shows that the decomposition of adsorbates occurs at the sample bias of 3.63 V, and proceeds with the lifetime of a few milliseconds. The details of the method will be provided at the discussion.

  • PDF