• 제목/요약/키워드: safety tests

검색결과 2,712건 처리시간 0.03초

H-pile의 지지력 특성 및 동역학적 공식의 신뢰도 평가 (Characteristics of Bearing Capacity and Reliability-based Evaluation of Pile-Driving Formulas for H Pile)

  • 오세욱;이준대
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.81-88
    • /
    • 2003
  • Recently, pile foundations were constructed in rough or soft ground than ground of well condition thus it is important that prediction of ultimate bearing capacity and calculation of proper safety factor applied pile foundation design. This study were performed to dynamic loading tests for the thirty two piles at four different construction sites and selected pile at three site were performed to static loading tests and then compare with measured value and value of static and dynamic loading tests. The load-settlement curve form the dynamic loading tests by CAPWAP was very similar to the results obtained from the static load tests. Based on dynamic and static loading tests, the reliability of pile-driving formula were analyzed and then suggested with proper safety factor for prediction of allowable bearing capacity in this paper.

LBLOCA AND DVI LINE BREAK TESTS WITH THE ATLAS INTEGRAL FACILITY

  • Baek, Won-Pil;Kim, Yeon-Sik;Choi, Ki-Yong
    • Nuclear Engineering and Technology
    • /
    • 제41권6호
    • /
    • pp.775-784
    • /
    • 2009
  • This paper summarizes the tests performed in the ATLAS facility during its first two years of operation (2007${\sim}$2008). Two categories of tests have been performed successfully: (a) the reflood phase of the large-break loss-of-coolant accidents in a cold leg, and (b) the breaks in one of four direct vessel injection lines. Those tests contributed to understanding the unique thermal-hydraulic behavior, resolving the safety-related concerns and providing an evaluation of the safety analysis codes and methodology for the advanced pressurized water reactor, APR1400. Several important and interesting phenomena have been observed during the tests. In most cases, the ATLAS shows reasonable accident characteristics and conservative results compared with those predicted by one-dimensional safety analysis codes. A wide variety of small-break LOCA tests will be performed in 2009.

SIMULATED AP1000 RESPONSE TO DESIGN BASIS SMALL-BREAK LOCA EVENTS IN APEX-1000 TEST FACILITY

  • Wright, R.F.
    • Nuclear Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.287-298
    • /
    • 2007
  • As part of the $AP1000^{TM}$ pressurized water reactor design certification program, a series of integral systems tests of the nuclear steam supply system was performed at the APEX-1000 test facility at Oregon State University. These tests provided data necessary to validate Westinghouse safety analysis computer codes for AP1000 applications. In addition, the tests provided the opportunity to investigate the thermal-hydraulic phenomena expected to be important in AP1000 small-break loss of coolant accidents (SBLOCAs). The APEX-1000 facility is a 1/4-scale pressure and 1/4-scale height simulation of the AP1000 nuclear steam supply system and passive safety features. A series of eleven tests was performed in the APEX-1000 facility as part of a U.S. Department of Energy contract. In all, four SBLOCA tests representing a spectrum of break sizes and locations were simulated along with tests to study specific phenomena of interest. The focus of this paper is the SBLOCA tests. The key thermal-hydraulic phenomena simulated in the APEX-1000 tests, and the performance and interactions of the passive safety-related systems that can be investigated through the APEX-1000 facility, are emphasized. The APEX-1000 tests demonstrate that the AP1000 passive safety-related systems successfully combine to provide a continuous removal of core decay heat and the reactor core remains covered with considerable margin for all small-break LOCA events.

현장재하시험을 통한 강관 매입말뚝의 지지력 안전율 제안 (Analysis of Bearing Capacity and Safety Factor of Dynamic Load Test of Prebored and Precast Steel Pile)

  • 박종전;정상섬;박정식
    • 한국지반공학회논문집
    • /
    • 제34권5호
    • /
    • pp.5-17
    • /
    • 2018
  • 본 연구에서는 풍화암에 근입된 강관 매입말뚝의 안전율 제안을 위하여 정재하시험과 동재하시험을 수행하였다. 현장재하시험은 직경이 0.508, 0.457m 인 시험말뚝을 제작하여 정재하시험(14회)과 동재하시험(EOID 14회, Restrike 14회)을 실시하였다. 이때, 재하시험은 시험말뚝 시공완료 후 (1)초기동재하시험(EOID)을 수행하였으며, (2)시공완료 28일 후 정재하시험을 시행하였으며, (3)정재하시험 완료 후 15일 후에 재항타동재하시험(Restrike)을 실시하였다. 본 연구 결과 Davisson 판정법의 동재하시험을 이용한 지지력 산정 결과 정재하시험 대비 재항타동재하시험은 약 15% 낮게 나타났다. 정재하시험과 동재하시험의 지지력 분석을 통하여 안전율을 비교하였고, 최종적으로 동재하시험 안전율을 기존 2.0에서 1.75로 수정 제안하였다.

시스템 LED 조명의 전기적·열적 안전성 확보 방안에 대한 연구 (A Study on the Electrical and Thermal Safety of System LED Lighting)

  • 김영우;김충혁;최운식
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.418-426
    • /
    • 2020
  • This study tested the electrical, structural, and thermal safety of LED lighting products, available on the market. Five recessed LED systems, 20 W each, and five fixed LED systems, 25 W each, were selected. Dielectric strength tests, live part electric shock protection tests, and thermal tests were conducted on the LEDs. These were key tests for user safety, according to the specification of the safety criteria for electric products, KC 60598-1, South Korea. In addition, the wiring temperature of UL1007, 60227 IEC 08, and UTP cables, was measured. The results of the study gave an in-depth examination of the safety of LED lighting systems for users.

모델기반 시스템엔지니어링 접근을 통한 고속철도 성능시험 및 안전기준 요구사항 관리체계 구축에 관한 연구 (A Study on Constructing the Requirement Management System of the Performance Tests and Safety Standards of the High Speed Railway using Model-Based Systems Engineering Approach)

  • 최요철;박영원;왕종배
    • 한국철도학회논문집
    • /
    • 제9권3호
    • /
    • pp.330-334
    • /
    • 2006
  • To maintain design-knowledge database and manage configuration for requirement of performance tests and safety standards of High Speed Railway(HSR), It is established that management system of performance tests and safety standards and then constructed that design-knowledge database and documented a performance test and safety specifications for supporting performance test and safety system using Model-Based Systems Engineering(MBSE) tool.

수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰 (Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash)

  • 이기연;길형준;김동욱;김동우;강대철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

다른 굵기의 6/10[kV]급 CV 케이블 직선접속부 안전성 평가 (A Safety Assessment of Splice of 6/10[kV] Class CV Cables with Different Conductor Size)

  • 정종욱;김선구;정진수
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.78-84
    • /
    • 2010
  • This paper describes the safety assessment of power cable splices connecting different sized 6/10[kV] class power cables. To assess the safety, AC withstand voltage tests, partial discharge tests and impulse tests were carried out to the cable splice specimens and thermal rise due to overload and cross section of joint were examined as well. As a result, a breakdown due to the $4.5[U_0](27[kV_{ac}])$ application could not found for 5 minutes. Under $1.73[U_0](10.4[kV_{ac}])$ application, partial discharges of 4~8[pC] were detected. In impulse tests, all the specimens withstood to the standard waveforms of $75[kV_{peak}](1.2{\times}50[{\mu}s])$ without any breakdowns. In addition, the temperature on the splice rose by $3[^{\circ}C]$ when the 200[A] flew through the splice for 20minutes, however the thermal rise of $3[^{\circ}C]$ was considered due to the atmospheric temperature. After all the electrical tests, the cross section of the splice was visually examined. The conditions of the conductors of both $185[mm^2]$ and $240[mm^2]$ were good.

산안법 관리대상물질의 변이원성 검색을 통한 GLP 유전독성 시험대상 후보물질의 선정 (Selection of Target Materials for GLP Genotoxic Tests by Searching the Mutagenicity Information of Chemicals by Occupational Safety and Health Act)

  • 임경택;임철홍;안병준
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.254-284
    • /
    • 2015
  • Objectives: There is a requirement to select target materials for mutagenicity(Genotoxicity) testing, so we determined to set the test priorities of them by searching the related database. Methods and Results: We searched a number of databases to find information on mutagenicity tests with chemicals under the Occupational Safety and Health Act(OSH Act), such as KOSHANET, National Toxicology Program(NTP), European Chemicals Agency(ECHA), US National Library of Medicine(NLM), and Genetic Toxicology Data Bank(GENE-TOX), as well as ChemIDplus webpage, and presented the information. Also we anticipated their hazards with ACToR sites to confirm the 58 mutagenicity(Genotoxicity) tests we will perform. Conclusions: We presented target materials for mutagenicity testing with specific GLP tests consisting of reverse mutation(Ames), chromosomal aberration and micronucleus test.

Dependence Potential of Quetiapine: Behavioral Pharmacology in Rodents

  • Cha, Hye Jin;Lee, Hyun-A;Ahn, Joon-Ik;Jeon, Seol-Hee;Kim, Eun Jung;Jeong, Ho-Sang
    • Biomolecules & Therapeutics
    • /
    • 제21권4호
    • /
    • pp.307-312
    • /
    • 2013
  • Quetiapine is an atypical or second-generation antipsychotic agent and has been a subject of a series of case report and suggested to have the potential for misuse or abuse. However, it is not a controlled substance and is not generally considered addictive. In this study, we examined quetiapine's dependence potential and abuse liability through animal behavioral tests using rodents to study the mechanism of quetiapine. Molecular biology techniques were also used to find out the action mechanisms of the drug. In the animal behavioral tests, quetiapine did not show any positive effect on the experimental animals in the climbing, jumping, and conditioned place preference tests. However, in the head twitch and self-administration tests, the experimental animals showed significant positive responses. In addition, the action mechanism of quetiapine was found being related to dopamine and serotonin release. These results demonstrate that quetiapine affects the neurological systems related to abuse liability and has the potential to lead psychological dependence, as well.