• Title/Summary/Keyword: safety management performance

Search Result 1,553, Processing Time 0.033 seconds

A Study on the Development of Marine Fuel Oil Homogenizer for Fuel Costs Saving (연료비 절감을 위한 선박용 연료유 균질기 개발에 관한 연구)

  • Han, Sang-Goo;Choi, Jung-Sik;Park, Ro-Seong;Kim, Dae-Hun;Ryu, Kyoung-Boo;Chun, Kang-Woo;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.584-590
    • /
    • 2012
  • In this study, we have conducted a work on homogenizer development which is operated by high shearing force generated by stator and rotor inside it. To investigate the performance for homogenization and atomization of homogenizer, Bunker-C (IFO 380 cSt) was used as a fuel for experiment. Pre-treatment of bunker-C was carried out with homogenizer developed in this study. Oil purifier was used to investigate effect of oil sludge reduction after pre-treatment. Experimental result showed that the amount of sludge of fuel oil after pre-treatment with homogenizer has decreased by 13 %. To confirm combustion efficiency, Bunker-C which have pre-treatment with homogenizer and purified after are burned in boiler system. The result showed that CO concentration in exhaust gas was decreased. These results mean that if the homogenizer which is developed in this study for marine fuel oil is applied on real vessels, oil costs and operating costs can be reduced.

Design Verification Method of Offshore Separation Systems Based on System Dynamics (시스템 다이내믹스 기반 해양구조물 분리시스템의 설계검증 방법에 관한 연구)

  • Hwang, John-Kyu;Ko, Jae-Yong;Lee, Dong-Kun;Park, Bon-Yeong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.715-722
    • /
    • 2020
  • This paper proposes a design verification method based on system dynamics for offshore separation systems. Oil and gas separation systems are key components of offshore oil platforms; these systems determine the competitiveness of engineering, procurement, and construction (EPC) projects, especially in terms of added value. However, previous research on design verification has been limited to the process and deliverables of design. To address this, the study aims to develop a comprehensive design verification method and the associated functions from the perspective of project management, for the entire project life-cycle of offshore structures. The proposed methodology for design verification is expected to contribute toward effective and detailed designs as well as improve the competitiveness of EPC companies in constructing of shore structures during the early design stages. We first analyzed the separation system of the FPSO using the design verification method adopted by advanced countries and compared it with the system dynamics process formalized as ISO 15288. Subsequently, a tailored process for the design verification of the offshore structure was derived. It is shown that the proposed design verification method can be applied to the front-end engineering design process of of shore structures. Moreover, it can contribute toward the successful performance of offshore projects in the future and also minimize design changes and critical risks during the construction of these offshore structures.

A study on characteristics of SOFC/GT system for the supply gas flow rates (공급가스 유량에 따른 SOFC/GT 시스템 특성에 관한 연구)

  • Park, Sang-Kyun;Lee, Joo-Hee;Park, Geong-Dae;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.765-772
    • /
    • 2015
  • In this research, the characteristics of SOFC/GT (Solid Oxide Fuel Cell/Gas Turbine) system temperature, stack power and system efficiency for flow rates of air, CH4 and water supplied to SOFC stack have been investigated. The temperature of the gas supplied to cathode and anode of SOFC stack in the SOFC/GT system are maintained by utilizing exhaust gas without the addition of external heat source. As a result, within the scope of this study, temperatures of gas supplied to cathode and anode of SOFC stack were maintained at 1000 (K) by utilizing the exhaust gas of the SOFC/GT system without the addition of external heat source. The system efficiency is increased with increase of air flow rate supplied to the stack and with decrease of $CH_4$ flow rate supplied to the stack. In addition, it can be found that the flow rate of the exhaust gas supplied to the turbine had a significant effect on the system efficiency. And the efficiencies of SOFC stack and SOFC/GT system depending upon various operating conditions of the SOFC/GT system is 51~57% and 57~73%, respectively.

Improving Reliabilities of Dam Displacement based on Monitoring Given Points by Total Station (기준점 측량을 활용한 광파기 기반 댐 제체 변위 계측 신뢰도 향상)

  • Kang, Gi-Chun;Kim, Bong-Jae;Hong, Seok-Woo;Yim, Yeon-Chool;Kim, Ji-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Displacement of dams by various instrumentations has been monitored for its safety management and analyzing the behavior after a dam collapse accident. However, unknown displacement of dam has frequently been occurred and it's difficult to analyze behavior of dams more accurately. In this study, improvement of reliabilities for displacement of dams measured by a total station was suggested by calibrating the monitoring system. The position of total station was initially measured through 2-3 given points and the coordinate of the total station was considered as an absolute value. Also, base horizontal and vertical angles had not been considered even if they are important factors when displacement was estimated. In this study, location of the total station and variations of base horizontal and vertical angles were investigated during measuring displacements of targeting points. From the results of this study, they are important factors which are affecting measurements of dam displacements. Before the calibrating, the displacement at 50 m from total station was ${\pm}20mm$. After the calibrating, the displacement was decreased by ${\pm}5mm$.

Job Analysis of Pediatric Occupational Therapists in Korea: Focused on Sensory Integration Intervention (아동작업치료사의 직무분석: 감각통합치료 중심으로)

  • Choi, Jeong-Sil;Hong, Eunkyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.15 no.2
    • /
    • pp.1-21
    • /
    • 2017
  • Objective : The aims of the this study is to identify job characteristics, to generate job description, and additionally to investigate duty task of the job for Korean pediatric occupational therapist focused on sensory integration intervention. Methods : In the first stage, job analysis of pediatric occupational therapist focused on sensory integration intervention was performed by an advisory committee consist of the DACUM panel. Through the job analysis, job description with definition was established. In the second stage, a survey was performed for 141 pediatric occupational therapist using a questionnaire based on the job description in order to investigate importance, frequency and difficulty of duty task and task elements of the job. This process was done from May to September 2017. Results : The job definition drew from this study was 'Pediatric occupational therapist provides occupational therapy services to children and adolescents to support occupational performance and social participation including daily activities and play". Through the job description established in this study, 9 duties (consulting, evaluation, intervention plan, intervention, document, education, self-development, management, and administration), 28 tasks and 169 task elements were drew. In the survey, among the duty tasks and task elements, 'ensure physical safety' and 'perform a session' were selected as the most important task, and 'ensure safety of children, sensory integrative equipment and environment' and 'prepare a safe environment' were selected as the most important element. Conclusion : This study defined job demands and characteristics of pediatric occupational therapist who performs sensory integration intervention. It is expected that this study can be used a resource to develop and/or improve educational program related.

Induction of the High Order Calibration Equation of Metal Oxide Semiconductor Gas Sensors (산화물 반도체식 가스센서의 입출력 고차 캘리브레이션 방정식 도출)

  • Park, Gyoutae;Kim, Kangmin;Lee, Hyeonggi;Yoon, Myeongsub
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.44-49
    • /
    • 2020
  • In this paper, a measuring circuit is designed through analyzing manufacture specification of the sensor based on MOS. And the best input-output polynomial are induced that really gas sensors are used in gas safety management industrial fields. Response characteristics of a MOS gas sensor is analysed by through sensor's output voltages are measured after standard gases with six kinds of concentrations are manufactured and are injected to the sensor. A lookup table is created by relations of sensor's output voltages by injecting gases with other concentrations. Because data of the formed lookup table are equal interval, a polynomial can be induced of method of approximation function. So the 5th polynomial of input-output for a sensor is defined, coefficients are calculated by using least squares method, and the 5th polynomial is completed for representing characteristics of the sensor. If the proposed polynomial is applied to gas leak detectors, an inverse transformation of polynomial and programing of array codes are recreated. In this research, polynomial is implemented with array types that intervals of values of a lookup table are one-fifth sampled and interpolated. The performance of proposed 5th calibration equation is verified that errors are reduced than a linear expression when tests are performed by measurement of concentrations against injection of standard gases.

A Study on Characteristics of Exhaust Gas Emissions of Water-Bunker Oil Mixed by Homogenizer (균질기에 의해 혼합된 물-벙커유의 배기가스 배출 특성에 관한 연구)

  • Choi, Jung-Sik;Han, Sang-Goo;Choi, Jae-Hyuk;Park, Sang-Kyun;Park, Ro-Seong;Kim, Dae-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.518-524
    • /
    • 2013
  • In this study, we conducted a study on characteristics of exhaust gas emissions from boiler when water-bunker oil mixed by homogenizer was burned in boiler. The results showed that NOx concentration and CO concentration of the homogenized bunker oil was decreased by 19% and 54% compared to pure bunker oil pretreatment was not being performed. And, in the case of water-bunker A oil, the NOx concentration was decreased with increasing water mixing ratio in bunker A oil. In particular, the NOx concentration in exhaust gas of 20 %water-80 %bunker A oil decrease by 45 % compared with pure bunker-A. However, the CO concentration in exhaust gas of 20 %water-80 %bunker A oil shows irregular changes. This means that the mixing of water more than a certain amount can cause a decrease in combustion performance. From this result, it can be found that critical mixing ratio of water in bunker A oil for normal combustion is 15% in this study. Deposition amount of soot that is collected in the vicinity of the chimney was decreased with increasing water mixing ratio.

Cost-Benefit Analysis Method for Ageing Equipment of Chemical Plants Using Risk Assessment (위험성평가를 이용한 노후설비에 대한 비용 편익분석 방법)

  • Jung, Soomin;Jung, Changmo;Kang, Seok-Min;Chae, Seungbeen;Kang, Seung-Gyun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.84-92
    • /
    • 2020
  • Most facilities in chemical plants operate in environments that are outside the range of temperature and pressure that can be encountered on a daily basis, and are vulnerable to aging due to these stresses and environmental conditions. The facilities exposed to these conditions are not only likely to fail due to cumulative damage, but also lead to accidents if maintenance and replacement are not performed.Recommendation guidelines called risk-based inspection are widely used around the world-wide. However, limits exist for facilities that have already elapsed for a certain. As a result of the survey on the aging of Ulsan industrial complex in Korea, which carries out proper inspection, many of the facilities have been used for 20 years. Also, most of the facilities where the accident occurred have been in operation for more than 20 years. Therefore, this study suggested criteria for classifying devices that have exceeded a certain period of use as obsolete facilities. In addition, quantitative risk assessment was conducted. The safety investment method using the cost-benefit analysis method was proposed in order to calculate the loss cost and reduce the risk by expressing the risks of the corresponding aged facility as an Economic index. By utilizing the method of cost-benefit analysis of old facilities using the quantitative risk assessment presented in this study, it can be expected to improve the performance and life of old facilities, improve production efficiency and reliability of the system of facilities, change the recognition of safety management costs, increase employee stability, and reduce loss costs.

Estimation Model for Freight of Container Ships using Deep Learning Method (딥러닝 기법을 활용한 컨테이너선 운임 예측 모델)

  • Kim, Donggyun;Choi, Jung-Suk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.574-583
    • /
    • 2021
  • Predicting shipping markets is an important issue. Such predictions form the basis for decisions on investment methods, fleet formation methods, freight rates, etc., which greatly affect the profits and survival of a company. To this end, in this study, we propose a shipping freight rate prediction model for container ships using gated recurrent units (GRUs) and long short-term memory structure. The target of our freight rate prediction is the China Container Freight Index (CCFI), and CCFI data from March 2003 to May 2020 were used for training. The CCFI after June 2020 was first predicted according to each model and then compared and analyzed with the actual CCFI. For the experimental model, a total of six models were designed according to the hyperparameter settings. Additionally, the ARIMA model was included in the experiment for performance comparison with the traditional analysis method. The optimal model was selected based on two evaluation methods. The first evaluation method selects the model with the smallest average value of the root mean square error (RMSE) obtained by repeating each model 10 times. The second method selects the model with the lowest RMSE in all experiments. The experimental results revealed not only the improved accuracy of the deep learning model compared to the traditional time series prediction model, ARIMA, but also the contribution in enhancing the risk management ability of freight fluctuations through deep learning models. On the contrary, in the event of sudden changes in freight owing to the effects of external factors such as the Covid-19 pandemic, the accuracy of the forecasting model reduced. The GRU1 model recorded the lowest RMSE (69.55, 49.35) in both evaluation methods, and it was selected as the optimal model.

Pullout Behavior of Mechanically Stabilized Earth Wall Abutment by Steel Reinforcement and Backfill Properties (금속 보강재와 채움재 특성에 따른 보강토교대의 인발거동 분석 연구)

  • Kim, Taesu;Lee, Soo-Yang;Nam, Moon S.;Han, Heuisoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.750-757
    • /
    • 2018
  • The mechanically stabilized earth wall abutment is an earth structure using a mechanically stabilized earth wall and it uses in-extensional steel reinforcements having excellent friction performance. In order to analyze the pullout behavior of in-extensional steel reinforcements usually applied on the mechanically stabilized earth wall abutment, effects of stiffness and particle-size distributions of backfills and also horizontal spacings were considered in this study. As a result of parametric analyses, the highest pulling force acted on the uppermost reinforcement, and the stiffness and the particle-size distributions of the backfill significantly affected the pulling resistance of the reinforced soils. The internal friction angle of backfills should be at least 25 degrees, the coefficient uniformity factor should be at least 4, and the horizontal spacing of the uppermost steel reinforcement should be less than 25cm. Therefore, in order to secure the pullout resistance of the reinforced soil, it is necessary a properly spacing of reinforcement and more strict quality control for the backfill.