• 제목/요약/키워드: safety device

Search Result 1,797, Processing Time 0.027 seconds

Investigation on Hermeticity of Liquid Crystal Polymer Package for MEMS Based Safety Device (MEMS 기반 안전 소자에 대한 액정 폴리머 패키지의 밀폐도 연구)

  • Choi, Jinnil;Kim, Yong-Kook;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.287-290
    • /
    • 2015
  • Liquid crystal polymer (LCP) is a thermoplastic polymer with superior mechanical and thermal properties. In addition, its characteristics include very low water absorption rate and possibility to apply bonding process under low temperature. In this study, LCP is utilized as a packaging material for a microelectronic system (MEMS) based safety device with suggestion of a low temperature packaging process. Highly sensitive and stable capacitive type humidity sensor is fabricated to investigate hermeticity of the packaged MEMS device.

A Study on Contact angle of the Linear Guide Way (리니어 가이드 웨이의 접촉각에 관한 연구)

  • Lee, Sun-Kon;Park, Young-Gee
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.11-16
    • /
    • 2009
  • This research investigates contact angle of Linear Guide Way through a experimental result and theoretical analysis. Since last ten years, most of researchers who concerned with the precision machinery and semiconductor device production etc. so the researches about Linear Guide Way have been unnoticed. The precision machinery and semiconductor device production system has the principle which transfers the mechanical moving to accuracy position control. The Linear Guide Way system has the principle which transfers mechanical moving to accuracy position control is very important to improve performance of the precision machinery and semiconductor device production system. So, In this research, in order to improvement for producing Linear Guide Way, bearing loading analysis and contact angle change through Linear Guide Way theoretical analysis and bearing modeling. Through this study, we may expect that there will be more improvement for producing Linear Guide Way.

Study on Smart Office Functionality Utilizing KEPCO Gateway (한전 Gateway를 활용한 Smart Office 기능 연구)

  • Nam, Kang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1107-1112
    • /
    • 2016
  • This study is the Smart Office features that take advantage of KEPCO eIoT(: energy Internet of Thing) platform, and it's Network configuration is composed of sensing device, gateway, platform, and the service server. The key features are parts for processing protocol data between the gateway and the device using LoRa(: Long Range) technology, Intelligent applications and public safety data connected to the PS-LTE(: Public Safety-Long-Term Evolution) system. And the resource tree provided Smart Office for the service, which commonly used in the application server and the device.

Study on Bursting Prediction of Rectangular Battery Case with V-Notch (직사각형 전지 케이스의 V-notch부 터짐 예측에 관한 연구)

  • Kim, S.M.;Song, W.J.;Ku, T.W.;Kim, J.;Kang, B.S.
    • Transactions of Materials Processing
    • /
    • v.18 no.1
    • /
    • pp.59-66
    • /
    • 2009
  • In this study, V-notch part has been considered as one of safety components in rectangular cup used for mobile device. This kind of safety component in rectangular cup with the V-notch part, which controls adequately the increased internal pressure in the rectangular cup, plays an important role to prevent the explosion from the excessive internal pressure. The protecting mechanism on the mobile device against the explosion is that a series of fracture on the V-notch part at the critical internal pressure level occurs. Therefore, it is very crucial to estimate accurately the working pressure range of the safety device. Relationship between the working internal pressure and fracture phenomenon at V-Notch part was investigated through numerical analysis using ductile fracture criteria. Integral value, I, of the used ductile fracture criteria was calculated from effective stress and strain, and then the bursting pressure of the V-notch part was extracted. Comparisons between the estimated and experimental results show that this systematic approach to predict bursting pressure using the ductile fracture criteria gives fairly good agreements.

The Study of the Fire Possibility of Sheath Heater without Safety Device in Use(Focused on the fire cases) (안전장치 없는 시즈히터에 대한 사용중 발화 가능성 연구(화재사례를 중심으로))

  • Mun, Yong-Su;Myeong, Jeong-Ho;Choe, Jin-Man;Kim, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.4 no.1
    • /
    • pp.62-69
    • /
    • 2004
  • The purpose of this study on the sheath heater having high occurrence of fires in a small work place because of not having the safety device, was to find out the characteristics required in the field examination of the fires in the courses of investigation. The results of the experiments conducted and reviewed on the basis of the fire cases whose conditions of the ignition possibility were divided into A, E, C and D are as follows: When the sheath heater without safety device is left on the condition of the heat accumulation of which the temperature rapidly rise, and then ignite the inflammables of the surroundings. In such cases, it was characterized that the color change trace appeared even if no short trace was discovered in the power line.

  • PDF

Effect of Improving Quality by Changing the Distribution Method of Shrimp Culture

  • KWON, Woo-Taeg;JUNG, Min-Jae;Woo, Hyun-Jin;LEE, Woo-Sik;KWON, Lee-Seung
    • Journal of Distribution Science
    • /
    • v.19 no.4
    • /
    • pp.53-60
    • /
    • 2021
  • Purpose: This study focuses on exploring ways to improve the distribution method of shrimp farming so that it is eco-friendly and increases the distribution of shrimp. Research design, data and methodology: The experimental device installed in a biofloc shrimp culture in one area tested 10 times. Complex odor, concentration of H2S, water quality improvement effected by decomposition of organic substances, and degree of microbial activation measured. The data of the experimental results verified using the T-test technique, and the p value was determined based on the significance probability of 0.05. Results: This experimental device was effective in reducing odor and hydrogen sulfide in shrimp farms. With the improvement of water quality, dissolved oxygen increased due to the microbubble and cavitation action of air ejector and ultrasonic waves. In addition, the cultured microorganisms in the cultured water treated by the experimental device were remarkably proliferated compared to the raw water. Conclusions: The biofloc distribution method has a significant effect on improving water quality and reducing odor substances and will become a new eco-friendly and efficient distribution method for shrimp farming in the future.

Collision Avoidance Sensor System for Mobile Crane (전지형 크레인의 인양물 충돌방지를 위한 환경탐지 센서 시스템 개발)

  • Kim, Ji-Chul;Kim, Young Jea;Kim, Mingeuk;Lee, Hanmin
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.62-69
    • /
    • 2022
  • Construction machinery is exposed to accidents such as collisions, narrowness, and overturns during operation. In particular, mobile crane is operated only with the driver's vision and limited information of the assistant worker. Thus, there is a high risk of an accident. Recently, some collision avoidance device using sensors such as cameras and LiDAR have been applied. However, they are still insufficient to prevent collisions in the omnidirectional 3D space. In this study, a rotating LiDAR device was developed and applied to a 250-ton crane to obtain a full-space point cloud. An algorithm that could provide distance information and safety status to the driver was developed. Also, deep-learning segmentation algorithm was used to classify human-worker. The developed device could recognize obstacles within 100m of a 360-degree range. In the experiment, a safety distance was calculated with an error of 10.3cm at 30m to give the operator an accurate distance and collision alarm.

Development of Real-Time Active Type Seals (실시간 능동형 타입 격납장치 개발)

  • Jung-ki Shin;Heekyun Baek;Yongju Lee
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.9-14
    • /
    • 2024
  • In order to thoroughly verify the denuclearization of the Korean Peninsula, it is urgent to develop technology capabilities to monitor, detect, collect, analyze, interpret, and evaluate nuclear activities using nuclear materials and secure nuclear transparency. The IAEA is actively using seal technology to maximize the efficiency of safety measures, and currently uses metal cap, paper, COBRA, and EOSS as seal devices. Unlike facilities that comply with safety measures requirements, such as domestic nuclear facilities, facilities subject to denuclearization are likely to have various risk environments that make it difficult to apply safety measures, and there is a high possibility that continuity of knowledge (COK) such as damage, malfunction, and power loss will not be maintained. This study aims to develop a real-time active seal device that can be applied in such special situations to enable immediate response in the event of a similar situation. To this end, the main functions of the real-time seal device were derived and applied, and a commercialized seal device and operation software. The real-time seal technology developed through this study can be applied to all nuclear facilities in South Korea, especially used as storage equipment for dry cask storage facilities of heavy water reactor's after fuel, and it is believed that unnecessary radiation exposure by inspectors can be minimized.

Development of Arm Fire Device for Solid Rocket (고체 추진기관 점화안전장치 개발)

  • Jang Seung-Gyo;Jung Jin-Suk;Kim In-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.169-172
    • /
    • 2005
  • The performance test result of the Arm Fire Device(Ignition Safety Device) for solid rocket which prevents accidental ignition was described. The results of the closed bomb test and the igniter test of the classical mechanical arm fire device and the advanced electro-mechanical arm fire device were presented, and according to the igniter test result it was realized that the electro-mechanical arm fire device has an advantage in aspect of the action time.

  • PDF

A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.150-163
    • /
    • 2022
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.