• 제목/요약/키워드: rubber glove

검색결과 13건 처리시간 0.023초

장갑의 치수규격 실태에 관한 연구 - KS와 ISO 치수체계를 중심으로 - (A Study on Actual Conditions of Glove Size Standards - Focused on KS and ISO Sizing System-)

  • 김은경;최혜선
    • 복식
    • /
    • 제54권6호
    • /
    • pp.77-90
    • /
    • 2004
  • The purpose of this study was to provide basic information requisite in the new sizing system for gloves. KS glove standards' size dimensions, size designation and labeling systems were analyzed. Also, KS glove standards' control sizes were compared to the anthropometric data of 824 Korean adults taken in the previous study. As well, the ISO hand size system was also compared to the anthropometric data of the previous study according to frequency tables of hand length and hand circumference. The size dimensions showed differences among KS standards and there was no size designation and labeling systems existed in KS standards. Among KS glove size systems, protective rubber gloves for radioactive contamination and surgical rubber gloves' size which followed ISO system were accurately indicate the hand size of the person a glove is intended to fit. ISO glove sizing system comprised the control dimensions of hand length and hand circumference. The coverage of ISO size A was 84.8% which was highest among ISO size A. B, C. And in hand circumference 178, 191, 203, 216mm showed the frequencies above 3% and in hand length 167, 175. 183, 191, 199mm showed the frequencies above 3%.

안전보호용 절연 고무장갑의 제조 및 특성 (Preparation and Properties of Insulating Rubber Gloves for Safety Protection)

  • 김공수;조석형;김상기
    • Elastomers and Composites
    • /
    • 제36권4호
    • /
    • pp.262-267
    • /
    • 2001
  • 내전압 특성과 항균성을 갖는 절연 고무장갑을 제조하기 위해 천연고무 라텍스 (NRL)와 수분산성 폴리우레탄 (PU) 그리고 4급 아민 키토산 (4N-chitosan)을 배합하여 침지법으로 제조하였다. 절연 고무장갑의 기계적인 특성은 폴리우레탄 함량이 증가할수록 인장강도는 증가하였으나 신장율은 저하되었으며, 노화후 인장강도 및 신장율의 잔존율은 폴리우레탄 함량 증가에 따라 증가하였다. 또한, 리칭시간이 증가할수록 내전압 특성이 증가하였으며, 3시간의 리칭시간에서 10000V의 내전압 성능을 나타내었다. 고무장갑에 4N-chitosan을 첨가한 결과 균이 거의 생존하지 않았다.

  • PDF

장갑 착용이 악력과 안전에 미치는 영향에 관한 연구 (A Study of the Effects of Wearing Gloves on Grip Strength and Safety)

  • 정화식;구동호
    • 대한안전경영과학회지
    • /
    • 제8권4호
    • /
    • pp.13-23
    • /
    • 2006
  • Grip strength provides a quick and objective index of the functional integrity of the upper extremities. It is widely used as an assessment measure in physical and rehabilitation medicine. In this study, maximum voluntary grip strength of 20 college students wearing 5 different gloves were measured using Jamar hand dynamometer. The results show that maximum voluntary grip strength was generally reduced when wearing gloves as compared to bare-handed. More specifically, the grip strength was highest when wearing PVC coated glove or bare-handed and getting lowered as wrist band, rubber, leather, and cotton glove in these order. Depending on the measuring posture of grip strength, shoulder height with arm extended forward was higher than the elbow was flexed 90 degree. Moreover, subjects' demographic factors and hand dimensions were not closely related to the grip strength. It is thus recommended that the proper glove should be provided to reduce the negative consequences including dropping a tool, poorer control of a tool. lower quality work, and increased muscle fatigue and in turn to increase the user safety and satisfaction.

Latent fingerprint development from rubber gloves using MMD I (Multimetal deposition I)

  • An, Jaeyoung;Kim, Heesu;Oh, Jungmin;Han, Sooyong;Yu, Jeseol
    • 분석과학
    • /
    • 제33권2호
    • /
    • pp.108-114
    • /
    • 2020
  • Gloves are very important evidence at a crime scene; specifically, rubber gloves can be found easily at homes. Therefore, crime scene investigators attempt to develop fingerprints inside the rubber gloves that are discovered, for identifying unknown suspects. This study compared the effectiveness of three different methods that are used for developing latent prints on gloves with aging time. These were the powder, cyanoacrylate fuming, and multi-metal deposition I methods. The powder method achieved good results for 1-3 days of aged prints, and the cyanoacrylate fuming method worked well on 2-week-old prints. In comparison, multi-metal deposition I method developed good quality fingerprints for 6 weeks of aging time.

고무장갑 재질 및 식품 오염에 따른 살균소독제의 황색포도상구균 저해 효과 (The Effect of Chemical Sanitizers on Reducing Staphylococcus aureus on Rubber Gloves Depending on Material and Food Contaminant)

  • 오민석;이선영
    • 급식외식위생학회지
    • /
    • 제5권1호
    • /
    • pp.1-4
    • /
    • 2024
  • This study investigated the effect of sodium hypochlorite and ethanol on reducing Staphylococcus aureus on gloves depending on material and food contaminant. S. aureus inoculated onto rubber gloves with various organic substances (pork extract, perilla leaf extract, and 0.2% peptone water) and inoculated rubber gloves were stored in a desiccator at 100% RH and 25℃ for 24 h before treatments with distilled water, ethanol, or sodium hypochlorite. Levels of S. aureus were significantly reduced on both types of rubber gloves when treated with ethanol and sodium hypochlorite. However, sodium hypochlorite treatment resulted in 3.27 log CFU/each of S. aureus in pork extract on nitrile gloves, indicating that the effectiveness of disinfection may vary depending on the glove material and the type of organic substance. The results of this study suggest that ethanol treatment is the most effective disinfection method for S. aureus on rubber gloves, regardless of the material and organic substances.

원위피판술을 시행한 환자의 손가락에 수술용 고무장갑을 이용한 간단한 조형법 (Simple Molding Method for Post-distant Flap Stated Finger by Using Surgical Rubber Gloves)

  • 김호길;최환준;김미선;신호성;탁민성
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.263-267
    • /
    • 2006
  • In both cosmetic and functional aspects, loss of digital pulp is a common problem. Compound or composite defects of the hand and fingers with exposed denuded tendon, bone, joint, or neurovascular structures may require flap coverage. Most often these lesions can be repaired by using simple local flap, neurovascular flap, thenar flap, and cross-finger flap. But microvascular reconstruction is sometimes needed for large defects. But Authors do not recommend these procedures in case of severe crushing injuries involving multiple finger pulp losses because they have possibility of damage of the vascular network and infection. So we applied distant flaps such as chest flaps, groin flaps, abdominal flaps and etc. And then we applied surgical rubber gloves for remodeling the flap after cutaneous healing. We have acquired satisfactory results, after the simple molding method for distant flap finger by using surgical rubber gloves treatment.

가공 배전선로 활선 정비 로봇 시스템의 기술 타당성 검토 (Technical Feasibility Study on Live-line Maintenance Robot System for Overhead Distribution Lines)

  • 박준영;이윤건;장영식
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.49-53
    • /
    • 2022
  • The distribution live-line work method is an operation method of working in a state in which electricity flows through overhead distribution lines to minimize inconvenience to electric customers due to power failure. In June 2016, to strengthen the safety of electrical workers, Korea Electric Power Corporation announced that it would in principle abolish the rubber glove method, in which workers wore protective equipment such as rubber gloves and performed their maintenance work. In addition, KEPCO announced that it would develop a short-range live working method using smart sticks and an advanced live-line maintenance robot system where workers work without touching wires directly. This paper is a preliminary study for the development of the live-line maintenance robot system, and deals with the results of analyzing the technical feasibility of whether the live works performed by workers can be replaced by robots or not.

소방공무원의 보호장비 착용실태에 관한 연구 -경남지역을 중심으로- (A Study on Wearing Practice of Personal Protective Equipment for Firefighter : Focusing on Gyeongnam Province)

  • 방창훈
    • 한국방재학회 논문집
    • /
    • 제10권6호
    • /
    • pp.65-71
    • /
    • 2010
  • 본 연구에서는 경남지역에 근무하는 소방공무원의 보호장비 착용실태를 연구하여 소방공무원의 안전보건에 대한 기초자료를 제공하고자 시도되었으며, 연구에서 얻어진 결과를 제시하면 다음과 같다. 첫째, 소방용 보호장비에 대한 전체 신뢰도는 3.19로 조사되었으며 신뢰도 향상을 위한 개선이 필요할 것으로 판단된다. 둘째, 소방공무원은 보호장비 중 가죽제 안전화(2.68), 장갑(2.67) 그리고 고무제 안전화(2.59)등에 낮은 만족도를 나타내었으며, 고무제 안전화(2.75), 다음으로 장갑(2.77), 가죽제 안전화(2.97)의 상태가 좋지 않은 것으로 조사되었다. 셋째, 소방용 보호장비에 대하여 소방공무원은 전체적으로 착용감과 무게에 많은 애로를 겪고 있는 것으로 나타났으며, 이를 개선하기 위하여 인체공학적 디자인과 고성능 경량의 소재 개발 등이 필요하다.

작업재해 예방을 위한 직접활선 작업방법 개선방안에 관한 연구 (A study on the improvement of rubber glove work to prevent the work accident)

  • 문수덕;이정관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.492-494
    • /
    • 2000
  • The rapid increase of electric power demand and the strong requirements for interuptiom-free made most distribution works being done by interruptiom-free work techniques. These trends lead to increase of accident by electric shock. It goes to prove that more than 80% of electric accident is due to the hot line works. Therefore, the countermeasures are very urgent. This paper suggests the improvement to prevent the work accident by interruption-free work through the examination of the present situation of interruption-free work techniques as well as analysing the problems in terms of live-line works and working procedures. These improvement will contribute to reduce the work accident in live-line work and enhance the construction quality by training and managing workers effectively.

  • PDF

소아환자복의 착의실태에 관한 연구 (The Actual Wearing Condition for the Uniform of Pediatric Inpatient)

  • 김미성;이정란
    • 한국의류학회지
    • /
    • 제36권11호
    • /
    • pp.1197-1207
    • /
    • 2012
  • This study provides information for the design of pediatric inpatient uniforms with functionality and aesthetic beauty through a questionnaire-survey of the conditions of providing, wearing, preferences and improvement requirements for pediatric inpatient uniforms. As a result of the survey, intravenous injections were mostly given on the back of the hand, and the method of changing uniforms after intravenous injections was (in most cases) to pass the injection bottle through a sleeve or pant leg while the needle is inserted. The respondents answered that the sleeve length and pant length did not match. As a result of the preference of the pediatric inpatient design survey, respondents indicated they preferred pajama type, yellow color and medium size animal patterns. A similar ratio of set-in and raglan with no collar but with 3/4 length sleeve of round neck, front end, sleeve top opening, button closing and two pockets were preferred for shirts; however, a 3/4 length with rubber string on the waist, no opening and inner opening were preferred at the same ratio for pants. As for the method to adjust the length to assign functionality to pediatric inpatient uniforms, the most preferred sleeve was a roll-up sleeve with a strap and the most preferred pants were length adjusted pants that used a strap for both shirts and pants with a both sides strap. In addition, the majority of the respondents answered that a hand wrapper that protects the injection location during intravenous injections needs be developed. As for the development type, a half glove type and glove type were preferred in sequential order.