• 제목/요약/키워드: rotor loss

Search Result 299, Processing Time 0.022 seconds

CFD Analysis for Optimization of Guide Vane of Axial-Flow Pump (축류펌프 안내 깃 최적화 설계를 위한 전산 유동해석)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.519-525
    • /
    • 2016
  • In a pump, from the performance point of view, it is very important to minimize the shock loss at the inlet of the rotor blades. In this study, the effects of shape and install angle of the inlet guide on the performance of an axial-flow pump are numerically simulated using commercial CFD code, Ansys CFX. Finally, to obtain the optimized shape of the vanes and the install angle of the vanes in the inlet guide under given operating conditions, optimization analysis is conducted using Analysis design exploration based on response surface optimization.

Status of 3 MW PM Synchronous Generator Development Project for Off-shore WECS (3MW 해상풍력용 영구자석 동기발전기 개발현황)

  • Kim, Dong-Eon;Han, Hong-Sik;Lee, Hong-Gi;Jung, Yung-Gyu;Suh, Hyung-Suck;Chung, Chin-Wha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.423-426
    • /
    • 2007
  • Pohang Wind Energy Research Center (PoWER-C) is developing a 3 MW Radial Flux Permanent Magnet (RFPM) Synchronous Generator for offshore Wind Energy Converter (WEC). The rotor rpm is 15.7 and the gear ratio is set to be 92.93. The nominal generator rpm at the rated load is about 1459. To reduce the switching loss in the power electronics, the maximum frequency is limited to 100 Hz. This requirement limits the number of pole to six or eight. Permanent magnet excitation is assumed for higher energy yield and higher efficiency. In this report, the requirements and the first efforts for the physics design are described.

  • PDF

Design and Drive of 3-phase 6/8 SRM (3상 6/8극 SRM의 설계 및 운전 특성)

  • Hao Chen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.48-55
    • /
    • 2003
  • The design and analysis of a three-phase 6/8 structure SRM(switched reluctance motor) art described. The range of the stator ole arc and the rotor pole arc of the motor we analyzed in the linear region. The optimum range of the stator pole arc and the turn-off angle of the main switches in the power converter are given with the 2-D finite element electro-magnetic field calculation of the motor and the nonlinear simulation. Test results of the prototype are discussed. This type is good for high efficiency drive because the drive circuit is simple and current density and copper loss of the winding are law.

Thermal Analysis of a Canned Induction Motor for Main Coolant Pump in System-Integrated Modular Advanced Reactor

  • Huh, Hyung;Kim, Jong-In;Kim, Kern-Jung
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.32-36
    • /
    • 2003
  • The three-phase canned induction motor, which consists of a stator and rotor with a seal can, is used for the main coolant pump (MCP) of the System-integrated Modular Advanced Reactor (SMART). The thermal characteristics of the can must be estimated exactly, since the eddy current loss of the can is a dominant parameter in design. Besides the insulation of the motor winding is compared of Teflon, glass fiber, and air, so it is not an easy task to analyze. A FEM thermal analysis was per-formed by using the thermal properties of complex insulation which were obtained by comparing the results of finite element thermal analysis and those of the experiment. As a result, it is shown that the characteristics of prototype canned induction motor have a good agreement with the results of FEM.

SRM drive system with reduced harmonics and improved power factor (고조파감소 및 역률개선을 위한 SRM 구동시스템에 관한 연구)

  • 신규재;권영안;임근희
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.10
    • /
    • pp.151-157
    • /
    • 1997
  • Switched relutance motor(SRM) has the advantages of simple structure, low rotor intertia, and high power rate per unit volume. However, SRM has the disadvantages of high current harmonics, and low power factor because of the discontinuous excitation of pulse type. The harmonics brings about the distortion and loss of power system, and brings about the incorrect opertion of electronic system. This paper investigates the SRM drive system with the reduced harmonics and improved power factor. The system consists of the switching power converter with poewr factor correction(SPC-PFC), DC/DC converter and 3-phase inverter. The performances in the proposed system are verified through the simpuation and experiment.

  • PDF

The On-line Observer System Characteristics Analysis of Synchronous Reluctance Motor Using a Coupled FEM & Preisach Model (유한요소법과 프라이자흐 모델을 이용한 동기형 릴럭턴스 전동기(Synchronous Reluctance Motor: SynRM)의 On-line 관측기시스템 특성해석)

  • Kim, Hong-Seok;Lee, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2103-2108
    • /
    • 2007
  • This study investigates the dynamic characteristics of Synchronous Reluctance Motor (SynRM), with segmental rotor structure, using finite element method in which the moving mesh technique is considered. The focus of this paper is the efficiency of on-line parameter identification system for position sensorless control of a SynRM considering saturation and iron loss. Comparisons are given with angle of the observer and those of proposed FEM & Preisach model of synchronous reluctance motor, respectively. The position sensorless control using identified motor parameters is realized, and the efficiency of the on-line parameter identification system is verified by experimental results.

Numerical simulation of turbulent flows through linear turbine cascades with high turning angles (전향각이 큰 선형터빈 익렬을 통하는 난류유동의 수치해석)

  • Lee, Hun-Gu;Yu, Jeong-Yeol;Yun, Jun-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.3917-3925
    • /
    • 1996
  • A numerical analysis on three dimensional turbulent incompressible flows through linear cascades of turbine rotor blades with high turning angles has been performed by using a generalized k-.epsilon. model which is a high Reynolds number form and derived by RNG(renormalized group) method to account for the variation of the rate of strain. A second order upwind scheme is used to suppress numerical diffusion in approximating the convective terms. Body-fitted coordinates are adopted to represent the complex blade geometry accurately. For the case without tip clearance, velocity vectors and static pressure contours are shown to be in good agreement with previous experimental results. For the case with tip clearance, the effects of the passage vortex and tip clearance flow on the total pressure loss as well as their interactions are discussed.

Off-line parameter Estimation of Induction Motors for Vector Control in Industrial Field (산업현장에서 벡터제어용 유도전동기의 오프라인 파라미터 추정)

  • 권병기;박가우;신원창;조응상;이진섭;최창호
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.234-238
    • /
    • 1998
  • Parameter estimation of induction motor for vector control presented in this paper can be easily implemented and applied to inverters in the industrial field, because it needs no additional hardware such as voltage sensor and measuring equipment. At first, the stator resistance including switching loss of inverter is measured by simple voltage-current equation. Next, in pre-magnetization of machine by imposing the d-axis constant field-current, q-axis torque current is forced to the machine until its speed feedback reachs to pre-defined level of speed limit. At this time, we can measure the rotor time-constant by decreasing the distorted output-voltage of inverter. At last, stator inductance, transient inductance, and moment of inertia can be measured by the relationship of output voltage, output torque and speed feedback. The validity and usufulness of this method is verified by experimental results.

  • PDF

Performance Analysis According to Parameter Measurement of Synchronous Reluctance Motor (자기저항 동기전동기의 정수추출을 통한 특성 연구)

  • Lee, J.S.;Hong, J.P.;Hahn, S.C.;Joo, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.73-75
    • /
    • 1999
  • The performance of a SRM in terms of torque and power factor depends on the two-axis inductances (Ld and Lq) and iron loss of the machine. Finite element method has been used to determine these parameters for a motor with segmented rotor structure. Fock and Hart Method has been conducted to compare to verify the accuracy of proposed analysis method.

  • PDF

A Study on the Flight-time Limitation at each Mission in Whole-Body Vibration Exposure of UH-1 Pilot (UH-1H 조종사의 전신진동 노출에 따른 임무별 비행시간 한계에 관한 연구)

  • 송근식;정완섭;이달호
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.353-358
    • /
    • 1998
  • Vibrations exposured to human whole-body are transmitted through the contact area of a human body, such as feet, hip and back directly in contact with vibrating surface. they apparently leads to the decrease of human comfort, the reduction of working efficiency or normal activities, and, furthermore, causes the loss of health and safety. In this study, UH-1 vibration has been measured to produce the flight-time limitation at each mission Results of this study show that the most significant peaks appear at a main rotor blade-passage frequency and that the vibration level in ground is higher than that in airborne In addition, it is shown that the most affective aspect for the flight-time limitation is ground vibration level

  • PDF