• 제목/요약/키워드: rotational measure

Search Result 134, Processing Time 0.213 seconds

Dynamics of RNA Bacteriophage MS2 Observed with a Long-Lifetime Metal-Ligand Complex

  • Kang, Jung Sook;Yoon, Ji Hye
    • Journal of Photoscience
    • /
    • v.11 no.1
    • /
    • pp.35-40
    • /
    • 2004
  • [Ru(2,2'-bipyridine)$_2$(4,4'-dicarboxy-2,2'-bipyridine)]$^{2+}$(RuBDc) is a very photostable probe that possesses favorable photophysical properties including long lifetime, high quantum yield, large Stokes' shift, and highly polarized emission. To evaluate the usefulness of this luminophore (RuBDc) for studying macromolecular dynamics, its intensity and anisotropy decays when conjugated to RNA bacteriophage MS2 were examined using frequency-domain fluorometry with a high-intensity, blue light-emitting diode (LED) as the modulated light source. The intensity decays were best fit by a sum of two exponentials, and the mean intensity decay time was 442.2 ns. The anisotropy decay data showed a single rotational correlation time (2334.9 ns), which is typical for a spherical molecule. The use of RuBDc enabled us to measure the rotational correlation time up to several microseconds. These results indicate that RuBDc can be useful for studying rotational diffusion of biological macromolecules.s.

  • PDF

Development of Measurement System for Tappet Rotation in the Valve Train System (밸브 트레인 시스템의 태핏 회전 측정 장치의 개발)

  • 김형준;조명래;신흥주;한동철
    • Tribology and Lubricants
    • /
    • v.14 no.3
    • /
    • pp.81-86
    • /
    • 1998
  • The purpose of this paper is to measure the rotational speed of tappet in OHC valve train system. Tappet has eccentricity about cam center, which induces the tappet rotation and prevents from wear. In this paper, the experimental test rig which composes of one cam system is developed to measure the tappet rotation by using the laser generating system, rotary encoder, optical fiber, and photo transistor. The direction of tappet rotation is judged from the oder of optical signal. As results of experiment, average and instant rotational speed and average rotation angle per one cam revolution are presented. Measured results show that eccentricity ratio is dominant factor for the tappet rotation, and tappet is rotated at the base circle.

The Measurement of the LIDAR Ratio by Using the Rotational Raman LIDAR

  • Choi, Sung-Chul;Baik, Sung-Hoon;Park, Seung-Kyu;Cha, Hyung-Ki;Song, Im-Kang;Kim, Duk-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.174-177
    • /
    • 2010
  • The rotational Raman LIDAR technique has been used to accurately measure aerosol optical properties such as backscatter coefficient, extinction coefficient, and LIDAR ratio. In the case of the vibrational Raman technique, the ${\AA}$ngstr$\ddot{o}$om exponent, which has wavelength dependence on the particle properties, is assumed to obtain the extinction coefficient. However, this assumed ${\AA}$ngstr$\ddot{o}$m exponent can cause systematic errors in retrieving aerosol optical properties. In the case of the rotational Raman technique, the aerosol optical properties can be measured without any assumptions about the ${\AA}$ngstr$\ddot{o}$m exponent. In this paper, the LIDAR ratio was measured by using the rotational Raman LIDAR and vibrational Raman LIDAR in the troposphere. And, the LIDAR ratios measured by these two methods were compared.

A Study on the Green Growth Effect with the Rotational and Up-and-Down type Streetlight (회전·승하강식 가로등주 활용을 통한 녹색성장 효과에 관한 연구)

  • Choi, Hyoung-Bum;Kim, Kyung-Chul;Oh, Sung-Hwan;Hwang, Young-Rok;Jung, Ji-Won;Park, Dong-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.19-23
    • /
    • 2011
  • The current streetlight system have been tried various attempts. but during maintenance, it has caused the traffic congestion and many risk factors. In addition, maintenance costs are very expensive to manage and the local government have to establish countermeasures about the present condition. If neglected, it may cause a variety of social problems. so, there should be a measure to prevent problems. This rotational and up-and-down type streetlight can be a solution to these factors and it has been highlighted indirectly in terms of green growth because we have to take advantage of the value.

Parameterizing the Perturbed Rotational Velocities of Planet-induced Gaps

  • Yun, Han Gyeol;Kim, Woong-Tae;Bae, Jaehan;Han, Cheongho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.63.2-63.2
    • /
    • 2019
  • Recent submillimeter observations of ALMA reveal that many protoplanetary disks contain substructures like gaps or rings. The disk-planet interaction is believed to be the most likely gap formation scenario, and most previous numerical work attempted to constrain the planet mass using the density profiles of gas in the gaps. Since the dust and gas distributions likely differ from each other in protoplanetary disks, however, perturbed rotational velocities that directly probe the gas would give a more reliable estimate to the planet mass. In this work, we run two-dimensional hydrodynamic simulations to measure the amplitudes and widths of rotational velocity perturbations induced by planets with different mass. We present the parametric relations of the gap widths and depths as functions of the planet mass and disk properties. We also apply our relations to HD 163296 to infer the masses of embedded planets.

  • PDF

Comparison of Hip Rotation Range of Motion in Jiu-Jitsu Athletes With and Without Low Back Pain (주짓수 선수의 허리 통증 유무에 따른 엉덩관절 돌림 가동범위 비교)

  • Yang, Sung-jun;Park, Kyue-nam;Kyung, Moon-soo;Kim, Si-hyun
    • Physical Therapy Korea
    • /
    • v.25 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Background: A limited hip rotational range of motion (ROM) has been considered to be one of characteristics of low back pain (LBP) in athletes. Although LBP frequently occurs in jiu-jitsu athletes, no previous has compared hip rotational ROM between jiu-jitsu athletes with and without LBP. Objects: The aim of the study was to compare ROM for hip internal rotation (IR) and external rotation (ER), and total hip rotation between jiu-jitsu athletes with and without LBP. Methods: Jiu-jitsu athletes were recruited for the LBP group ($n_1=15$) and control group without LBP ($n_2=15$). IR, ER, and total rotational range of hip joint were measured using a goniometer. Analysis of variance was used to compare the ROM between groups and sides. Results: The LBP group showed a significantly lower range of passive hip IR, passive total rotation, active IR, active ER, and active total rotation than the control group (p<.05). Dominant side of passive hip IR and active IR had a significantly lower ROM than non-dominant side (p<.05). In passive ER ROM, non-dominant side was significantly greater than dominant side (p<.05). Conclusion: Compared to jiu-jitsu athletes without LBP, athletes with LBP exhibit a loss of hip rotational ROM. Based on these results, clinicians and athletic trainers should measure hip rotational ROM when designing the management plan for jiu-jitsu athletes with LBP.

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

A Study on the Amount of Mandibular Rotation and Pattern of Condylar Path (하악운동 회전량과 과로의 형태에 관한 연구)

  • Kyung-Soo Han;You-Me Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.369-382
    • /
    • 1996
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronicⓡ and mandibular rotational torque movements with BioEGNⓡ. For this study 56 patients with Temporomandibular disorders(TMD) and 30 dental students without any masticatory signs and symptoms were selected as patients group and control group, respectively. The items recorded with Pantronicⓡ(Denar Corp., USA) were immediate side-shift, progressive side-shift, angle of orbiting path, protrusive path and PRI. BioEGNⓡ(Bioelectric gnathography, Bioresearch Inc., USA) were used to measure the amounts of mandibular rotational torque movements in frontal and horizontal plane, and the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement depicted between the condyles was automatically analysed by angle and difference in frontal and horizontal plane. The obtained data were processed with SAS program and the conclusion of this study were as follows : 1. Mean values of items between patients group and control group in Pantronic measurements were not significantly different except in left protrusive path and in Pantronic Reproducibility Index(PRI). There were no significant difference of condylar paths by preferred chewing side and affected side between the two groups. 2. The amount of mandibular rotational torque movements were differed in frontal angle and difference on protrusion, and in frontal and in horizontal difference on left excursion between the two groups. But the amounts of translatory movements were actually same on all eccentric movements. 3. The amount of mandibular rotational torque movements with splint mere almost not changed from those without splint, with the exception of in horizontal measurements on protrusion. 4. The correlations of items between in Pantronic measurements and in BioEGN measurements wert not consistently, significant, however, generally the ISS related significantly with horizontal torque movement positively, and with frontal torque movement negatively on the contrary, the PSS showed positive correlation with frontal torque movement, and negative correlation with horizontal torque movement.

  • PDF

A Study on Effect of Tool Wear Rate upon Cutting Tool Shape in a Titanium Rough Cut Machining (티타늄 황삭가공에 있어서 공구형상이 공구마모율에 미치는 영향에 관한 연구)

  • Jung, Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.27-33
    • /
    • 2019
  • The aviation industry has grown beyond the simple processing and assembling of aircraft parts and now designs and exports finished aircraft. In this study, the vertical CNC milling rotational speed and feed rate were parameters to investigate the life of tools according to their shape: (flat, round, and ball end mill) in the rough cutting of titanium. These tools are widely used in aircraft manufacturing and assembly. The purpose of this study is to measure the cutting temperature generated during the cutting process and calculate the rate of tool wear. This will be accomplished by measuring the tool weight before and after cutting the specimen and to compare it with the results of previous studies. Our study showed that the maximum cutting temperature increased as cutting time, tool rotational speed, and feed rate increased. The highest cutting temperatures were recorded for the ball, round, and flat end mill, respectively. Tool wear for the ball, round, and flat end mill increased as the speed and feed rate increased. The flat end mill exhibited the highest rate of wear from a minimum of 0.62% to a maximum of 2.88%.