• Title/Summary/Keyword: restoration material

Search Result 687, Processing Time 0.025 seconds

RADIOGRAPHIC EVALUATION OF THE PROXIMAL BONE LEVEL BETWEEN TWO IMPLANTS : A 3-YEAR COMPARATIVE STUDY BETWEEN BR$BR{\AA}$NEMARK AND ITI IMPLANTS IN THE MANDIBULAR POSTERIOR REGION (하악 구치부에 식립된 Br${\aa}$nemark 임프란트와 ITI 임프란트에서 임프란트간 치조정간골의 높이변화에 대한 방사선학적 비교)

  • Yi, Sang-Hwa;Cha, In-Ho;Shim, June-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.458-470
    • /
    • 2004
  • Statement of problem: Br${\aa}$nemark or ITI are two currently most widely used implant systems but with contrasting design, surgical and restoration methods. Purpose: The purpose of this study was to compare changes and its statistical significance in bone height and shape which may rise due to the differences between two implant systems. Also to analyse the effect of inter-implant distance on annual bone height changes. Material & Method: Those patients who were treated with two or more of either Br${\aa}$nemark or ITI implants at posterior mandibular area at Yonsei University Dental Hospital, Implant Clinic were selected. At annual examination appointments, standardised radiographs using parallel technique were taken. Marginal bone and inter-implant crestal bone changes were measured and following results were obtained. Results: 1) When ITI and Br${\aa}$nemark system were compared, both annual marginal and inter-implant crestal bone height changes in ITI system in the first two years were smaller than Br${\aa}$nemark and they were statistically significant. On the third year, however, there was no statistical difference between two implant systems on their annual bone level changes (p>0.05). 2) The Marginal and inter-implant crestal bone changes were compared when inter-implant distance was less than 4mm. Statistically significant bone level changes were noted on the first year only for ITI implants but in the first and second year for Br${\aa}$nemark implants (p>0.05). 3) When comparing angulation changes between marginal bone and implant fixture, ITI system had smaller angulation changes but the annual changes were not statistically significant (p>0.05). Conclusion: Within the limitation of this study, it could be concluded that Br${\aa}$nemark implant systems had more changes in marginal and inter-implant crestal bone level in the first and second year after loading with statistical significance. Further studies are recommended to see the effects of these bone loss during the first and second year after loading on the long term prognosis of Br${\aa}$nemark Implants.

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

A STUDY OF THE EFFECT OF LOW INTENSITY INITIAL LIGHT CURING ON THE BOND STRENGTH OF RESIN RESTORATION (초기 저광도 광중합이 레진 수복물의 결합강도에 미치는 영향에 관한 연구)

  • Han, Mi-Ran;Kwon, Soon-Won;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.45-53
    • /
    • 2001
  • Recently some studies have shown that low light intensity followed by final cure at high light intensity may result in a smaller marginal gap and may be no negative effect on material properties. The purpose of this study was to evaluate the influence of the initial cure with low intensity on the shear bond strength of dentin and the microhardness of composite resin. Twenty intact bovine teeth were prepared for shear bond strength test and each tooth sectioned to three specimens. The specimens were randomly divided into three groups according to the light intensity and curing time as follows; Group I. $450mmW/cm^2$ 40sec Group II. $300mmW/cm^2$ 20sec and $600mmW/cm^2$ 20sec Gropu III. $250mmW/cm^2$ 20sec and $450mmW/cm^2$ 20sec. Samples of each group were restored with light-cured composite resin after dentin bonding and then the shear bond strength of each specimen were measured using universal testing machine. Ten resin specimens per group were prepared. After 24 hours, the Vickers microhardness value was measured at the top and bottom surfaces. The result are as follows; 1. Mean value of low initial intensity groups(II, III) were higher than the control group(I) in shear bond strength, but no significant difference could be found. 2. No significant difference could be found between three groups in microhardness.

  • PDF

Trail Deterioration and Distribution Characteristics of South-North Green Corridor in Incheon, Korea - A Case Study of Mountainous Type Urban Natural Parks - (인천시 남북녹지축 탐방로의 분포와 훼손특성 -산지형 도시자연공원을 사례로-)

  • Cho Woo;Oh Kang-Im;Bae Joong-Nam
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.4
    • /
    • pp.359-368
    • /
    • 2004
  • The purpose of this study is to examine distribution and damages of the trails of inquiry of urban natural parks. Those parks were located at south-north green corridor at Incheon being mountainous type of urban natural parks that were core area of urban ecosystem preservation to of urban natural parks that citizens recently made use of them as nature experience type of leisure and recreation place from time to time, and to supply basic material deciding on the ways to improve the trails of nature preservation type. The survey sites included Geyang Park, Baekma Park, Yaksa Park, Munhak Park and Cheongryang Park. The number of main trails was 42 at Geyang Park, 43 at Baekma Park, 9 at Yaksa Park, 28 at Munhak Park, and 22 at Cheongryang Park, and it was excessively more than optimum needed: The number of branch trails of the parks seemed to increase. The bared trail width in average of the roads was 3.5m, while maximum depth in average was 21.3cm. The trails were thought to be deteriorated rapidly without systematic maintenance. The 5th and 6th grade of the impact rating class that required restoration because of serious deterioration occupied 19.6∼78.0%. Based on the findings, the study suggested ways to improve and manage the trails of inquiry of urban natural parks that were placed at south-north green corridor at Incheon.

Effect of Mn and Fe Compound on the Absorption in the Body and Genital Organs, Activity with F344 Rats (F344 rats를 이용 망간 및 철 화합물의 체내 흡수와 생식기 및 운동성에 미치는 영향)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jeong-Hee;Choi, Sung-Bong;Kang, Min-Gu;Lee, Chae-Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.224-234
    • /
    • 2007
  • This study aimed to examine the harmful effects of Mn and Fe, which may be generated as dust or fume in the industrial sites, on the body and genital organs by their inhalation. It is intended to find the characteristics and differences of the hazardousness by inhaling a single and the mixed materials of Mn and Fe. Male F344 rats were divided into the control group and 3 exposed groups on the basis of the test material compound (Mn $1.5mg/m^3$, Mn 1.5 and Fe $3.0mg/m^3$, Fe $3.0mg/m^3$). The 4 groups were divided into 4 subgroups again on the basis of the exposure period (4 and 13 weeks) and the recovery period (4 and 13 weeks). The exposure condition was 6 hours a day, 5 days a week for the whole body. Clinical tests including changes in weight and feed rate, blood biochemical test, motility change, changes in the number and the amount of spermatozoon (sperm count), daily sperm production (DSP), deformity test of spermatozoon and changes in the accumulation of Mn and Fe in blood and internal organs were performed. Motility was reduced by Mn exposure. Especially, the effect of Mn was exposure period responsible. By mixing with Fe, no significant change in motility Mn and Fe accumulation in organs was observed. Sperm count and daily sperm production (DSP) were decreased by Mn. Additional effect like the reduction of sperm count and DSP, and delayed restoration of sperm count and DSP during the recovery period were observed in the mixed exposure group. These results indicate that Mn and Fe may affect the motility reduced and has male reproductive toxicity. Mixed exposure of Mn and Fe lead to synergic effects on the male reproductive toxicity.

A study on linguistic the validity of characteristics and picture test inventories to persons with developmental disabilities (발달장애인의 언어적 특성과 그림검사의 타당도 연구)

  • Lee, Dal-Yob;Noh, Im-Dae;Lee, Seung-Wook
    • 한국사회복지학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.497-531
    • /
    • 2002
  • It is very important for rehabilitation to deal with psychological aspects of persons with disabilities, as well as efforts improving the institutional and environmental conditions. A majority of persons with severe disabilities in the situation of Korea have difficulty in having and maintaining a job. Work should and would be a source of self-respect and material well-being in this modern society. Therefore, Vocational rehabilitation services are measures in restoration of family functions and social participation of persons with disabilities. This study aims at investigating linguistic characteristics and the validity of constructional concepts of picture interest test Inventories that have been utilized for the segregated groups of people such as persons with developmental disabilities. Picture interest test inventories seemed to be valid for measuring psychological traits and characteristics of people with mental retardation, and this finding can be extended to the group of other developmental disabilities, such as learning disabilities and mild/moderate behavioral deficits. The Holland classification system seemed to be best fitted for developing a comprehensive and accurate vocational interest inventory.

  • PDF

REINFORCEMENT OF FRACTURE RESISTANCE AFTER APEXIFICATION : CASE REPORT (치근단 형성술 후 약화된 치아의 파절 저항성 보강: 증례보고)

  • Lee, Young-Ho;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.397-403
    • /
    • 2012
  • The vitality of immature tooth could be lost by dental caries, trauma and fracture of malformed tooth. The vitality loss might lead to halt of the development of the root. The recommended endodontic treatment for a non-vital immature permanent tooth is apexification. Apexification is a method of inducing apical closure through the formation of mineralized tissue in the apical pulp region. Calcium hydroxide is the material of choice for apexification. Long-term exposure to calcium hydroxide may form the apical hard tissue, but weaken the dentin due to its alkaline nature and thus make the roots more susceptible to fracture. It is important to preserve any weakened tooth, so a permanent restoration is needed to reinforce teeth that are prone to fracture. The purpose of this case report was to describe the treatment for reinforcing immature teeth treated with long-term calcium hydroxide. In these cases, the apexes of teeth were sealed with MTA plugs and the root canals were restored with composite resin and fiber post.

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF ZIRCONIA CORE ON THE COLOR OF CERAMIC (지르코니아 코아가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석)

  • Pae Ah-Ran;Baik Jin;Woo Yi-Hyung;Kim Hyung-Sup;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.466-477
    • /
    • 2005
  • Statement of problem : Problem of matching the appearance of porcelain restorations with the patient's natural dentition has always been a concern to dental clinicians. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. Among the various factors, shade and translucency or the core can significantly affect the overall esthetics of the restoration and should be considered when selecting an all-ceramic system. Purpose : The purpose of this study was to spectrophotometrically evaluate the influence of different zirconia systems and core thickness on the final shade of all-ceramic restorations using the CIEL$^*a^*b^*$ system. Material and Methods: Core specimens (n : 20 per group) of In-Ceram Alumina, In-Ceram Zirconia, Digident CAD/CAM Zirconia, Cercon Zirconia were fabricated 20mm in diameter. 10 specimens of each group were fabricated at core thickness of 0.5mm and 0.7mm. These core specimens were veneered with shade Al & A3 porcelain of the recommended manufacturer. CIEL$^*a^*b^*$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan). Color differences were calculated using the equation ${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{\frac{1}{2}}$. Results : 1. Specimens of core thickness 0.5mm and 0.7mm did not exhibit clinically perceived color difference. 2. Regarding shade reproducibility, In-Ceram Alumina and In-Ceram Zirconia showed significant difference within each group. 3. Cercon Zirconia group showed the highest $L^*$ value and Digident Zirconia group showed lowest $a^*$ & $b^*$ value. 4. Generally the shade difference between materials was higher in the A3 shade group than in the Al shade group. Conclusion: Within the limitations of this study, there was no color difference after increase in core thickness and every all-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

A Study of Material and Production Technique of Scroll Painting Ring in Joseon (조선시대 족자 장황에 사용된 고리의 재료 및 제작기법 연구)

  • Jang, Yeonhee;Yun, Eunyoung;Kwon, Yoonmi;Kim, Sooyeon
    • Conservation Science in Museum
    • /
    • v.16
    • /
    • pp.56-81
    • /
    • 2015
  • Ring in the scroll painting is one of the mounting elements which are fixed string and tassel to hang, these differ widely in shape and produce a variety of metals. Most traditional shapes of ring have been lost, because of remount, there are used Japanese style rings in present.Therefore, this study examines to shape, production technique and analyze component traditional style rings of 19 traditional scroll paintings in National Museum of Korea for restoration of original style. Ring has been recorded official names; Wonhwan(Ring), Gukhwadong(Chrysanthemum shaped ornaments), Baemok(Ring-shaped nail) in Uigwe. Result of an optical microscope (Leica, M205A), Wonhwan has two type of production technique; one is cutting and bending a metal rod and other is cast. Baemok is made to forging process after metal rod or plate by casting alloy. Baemok decoration is metal plate cutting shape, and then decorates it with pattern by using kicking line engraving, chasing and so on. Component analysis result from portable X-ray fluorescence found various metals, such as, brass, iron silver-cooper. Brass based on copper and zinc used rings of 17 scroll painting. Baemok of Yun Sidal portrait is used iron and plated with a tin-lead alloy. Yi Seogu portrait is silver-cooper alloy in whole ring.