• 제목/요약/키워드: rest position

검색결과 285건 처리시간 0.025초

골반압박벨트가 정상인의 능동 하지직거상 시 복횡근 굵기에 미치는 영향 (Effects of Pelvic Compression Belt on The Thickness of Transversus Abdominis During Active Straight Leg Raising in Healthy Subjects)

  • 김수현;박미희;심진아;이경아;김선엽
    • 대한정형도수물리치료학회지
    • /
    • 제17권1호
    • /
    • pp.15-23
    • /
    • 2011
  • Background: The objective of this study was to determine the effectiveness of the pelvic compression belt (PCB) on the thickness of the transversus abdominis (TrA) during active straight leg raising (ASLR). Methods: Thirty healthy subjects (10 men and 20 women) volunteered to participate in this study. The thickness of TrA was measured using a real-time ultrasonic diagnostic imaging system. Subjects were instructed to rest in a resting (hook-lying) position and to perform ASLR with and without the PCB. The PCB was positioned below the anterior superior iliac spine with stabilizing pressure from elastic bands. Results: In the resting position and during ASLR, the thickness of the TrA significantly differed between subjects with and without PCB (p<.05). In addition, there was a significant interaction between the measurement position and the presence or absence of PCB (p<.05). Conclusions: These findings suggest that the PCB may affect deep core muscles such as TrA during various activities. Further studies are required to generalize the results of the present study.

  • PDF

Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

  • Shah, Farhan Khalid;Gebreel, Ashraf;Elshokouki, Ali Hamed;Habib, Ahmed Ali;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.61-71
    • /
    • 2012
  • PURPOSE. To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS. Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS. Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION. Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.

척추마취 수술환자의 간호요구 (A Study on Needs of the Spinal anesthesia Patients)

  • 남성미;김명희
    • 성인간호학회지
    • /
    • 제12권4호
    • /
    • pp.666-677
    • /
    • 2000
  • The purpose of this study was to identify the needs which were perceived by patients who were received spinal anesthesia for surgery. The subjects consisted of 50 adult patients who were admitted to 2 university hospitals and 2 general hospitals in Pusan city and 1 general hospital in Koje City for surgery under spinal anesthesia. Thirty eight percent of subjects received information about anesthesia before the operation. The instrument for this study was developed by the researcher based on literature and a pretest. Data were collected from December 10, 1999 to February 10, 2000 and were analyzed by content analysis. The results were that there were 533 meaningful statements in the needs of spinal anesthesia patients. The needs of spinal anesthesia patients had 51 items (preoperation (6), induction of anesthesia(5), intraoperation (27), postoperation(13)) and 6 categories (information, emotional welfare, physical welfare, post anesthetic management, control of physical environment, humane treatment). From the results, it can be concluded that: 1. In the pre-operation period, we have to explain anesthesia procedures, adequate position of anesthesia, duration before anesthesia wears off and sensation of paralysis. We have to supply emotional support to relieve anxiety because of anesthesia. 2. In induction of anesthesia, we have to support patient's position for anesthesia, and relieve anxiety so that patients participate in induction of anesthesia well. 3. In intra-operative period, we have to check the level of anesthesia, and keep up a comfortable position for operation and care for physical discomfort such as thirst, nausea, vomiting, dyspnea and to maintain body temperature of the patient. Since the patient is conscious, we have to communicate with the patient to relieve anxiety, maintain privacy, inform the patient of the process of the operation and encourage the surgeon to explain the outcome of the operation. The operating team needs the careful about what they say and to place the instrument well. We have to ventilate the room air and reduce noise. 4. In the post-operative period, we have to explain the purpose and duration of bed rest, complications of anesthesia and care for physical discomfort such as pain, dysuria, headache, backache. Also we have to maintain body temperature of the patient and maintain privacy.

  • PDF

고관절 내전근 수축이 복횡근의 두께변화에 미치는 영향 (The Effect of Change in Transversus Abdominis Thickness Using Ultrasound Image during a Hip Adductor Contraction)

  • 문현주;구봉오
    • 대한물리의학회지
    • /
    • 제6권3호
    • /
    • pp.287-292
    • /
    • 2011
  • Purpose :The present study invesigated the effect of changes in transversus abdominis thickness using ultrasonography during a hip adductor contraction. Methods : This study was carred out in a volunteer sample of adults (N=30) without a history of low back pain or injury. In standing position, muscle thickness measurements of transversus abdominis(TrA) were measured using ultrasonography at rest and during a hip adducor contraction. Results : TrA thickness were influenced a hip adductor during a voluntary contraction in people without LBP. TrA showed significantly greater thickness changes on a hip adductor contraction.(p=0.000) Conclusion : The results from this study showed that the hip adductor contraction improves the ability to increase change in TrA thickness. These results can be a good evidence to prevent low back pain due to hip adductor weakness or genu varum deformity of knee osteoarthritis.

단일 구동부를 갖는 2축 도립 진자를 위한 제어기 구현 (An implementation of a controller for a double inverted pendulum with a single actuator)

  • 남노현;이건영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.257-260
    • /
    • 1997
  • In this paper, the double inverted pendulum having a single actuator is built and the controller for the system is proposed. The lower link is hinged on the plate to free for rotation in the x-z plane. The upper link is connected to the lower link through a DC motor. The double inverted pendulum built can be kept upright posture by controlling the position of the upper link even though the proposed inverted pendulum has no actuator in lower hinge. The algorithm to control the inverted pendulum is consisted of a state feedback controller within a linearizable range and a fuzzy logic controller coupled with a feedback linearization control for the rest of the range. Concept of the virtual work is employed to drive the linearlized model for the state feedback controller. The feedback linearization controller drives a DC motor with the modified reference joint angle from the fuzzy controller which adjusts a upright posture of a proposed pendulum system. Finally, the experiments are conducted to show the validity of the proposed controller.

  • PDF

마디모를 이용한 전방십자인대 기능 시뮬레이션 모델 (A Simulation Model of the ACL Function Using MADYMO)

  • 박정홍;손권
    • 대한기계학회논문집A
    • /
    • 제30권11호
    • /
    • pp.1408-1416
    • /
    • 2006
  • A mathematical knee model was constructed using MADYMO. The purpose of this study is to present a more realistic model of the human knee to reproduce human knee motion. Knee ligaments were modeled as line elements and the surrounding muscles were considered as passive restraint elements. A calf-free-drop test was performed to validate the suggested model. A calf was dropped from the rest at about 65 degree flexed posture in the prone position. The motion data were recorded using four video cameras and then three dimensional data were acquired by Kwon3D motion analysis software. The results showed that general shapes of angular quantities were similar in both the experiment and computer simulation. Functional stability of the anterior cruciate ligament was explicitly revealed through this model.

Comparative RFLP Analysis of Chromosome 2M of Aegilops comosa Sibth et Sm. Relative to Wheat (T. aestivum L.)

  • Park, Y. J.;Shim, J. W.
    • 한국작물학회지
    • /
    • 제43권2호
    • /
    • pp.120-123
    • /
    • 1998
  • Based on the co-linearity in the Triticeae, comparative RFLP analysis of 2M chromosome of Ae. comosa Sibth et Sm. was performed with 2MS and 2M additional lines of Triticum aestivum L. cv. Chinese Spring. Among the wheat RFLP probes conserved in the short arms of wheat chromosome 2, those above psr912 were located on the long arms of 2M in Aegilops comosa. The rest probes on the short arm and all the probe sequences on the long arm of group 2 chromosome in wheat were conserved on the equivalent chromosomal position in Aegilops comosa. So, it is apparent that some chromosomal segment from the short arm had been transferred to long arm while reconstructing 2M chromosome relative to wheat chromosomes. The break-point was located between psr912 and psr131 of the short arm. This rearrangement of chromosome 2M might be a molecular evidence of the M genome speciation from an ancestral type.

  • PDF

파워 스탠딩 휠체어의 설계 및 제작에 관한 연구 (The Study on Designing and Making Power Standing Wheelchair)

  • 조장현;송요창
    • 한국정밀공학회지
    • /
    • 제25권10호
    • /
    • pp.92-98
    • /
    • 2008
  • This paper is concerned with the designing and making power standing wheelchair. This wheelchair is studied based on the mechanical and electrical engineering concepts and theories. The mechanical theories are composed of statics and dynamics knowledges that are related with moving and standing position. Basically the static and dynamic stability is the most important element in designing and making the real size model. The linear actuator is used in the standing mechanism and the joystick controlled by hand is attached on the arm rest. The real size model is made and also investigated through the design specifications by test drive. Finally, this paper proves the possibility of commerical production of power standing wheelchair.

A Novel Stiff Membrane Seesaw Type RF Microelectromechanical System DC Contact Switch on Quartz Substrate

  • Khaira, Navjot K.;Singh, Tejinder;Sengar, Jitendra S.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권3호
    • /
    • pp.116-120
    • /
    • 2013
  • This paper proposes a novel RF MEMS dc-contact switch with stiff membrane on a quartz substrate. The uniqueness of this work lies in the utilization of a seesaw mechanism to restore the movable part to its rest position. The switching action is done by using separate pull-down and pull-up electrodes, and hence operation of the switch does not rely on the elastic recovery force of the membrane. One of the main problems faced by electrostatically actuated MEMS switches is the high operational voltages, which results from bending of the membrane, due to internal stress gradient. This is resolved by using a stiff and thick membrane. This membrane consists of flexible meanders, for easy movement between the two states. The device operates with an actuation voltage of 6.43 V, an insertion loss of -0.047 dB and isolation of -51.82 dB at 2 GHz.