DOI QR코드

DOI QR Code

Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

  • Received : 2011.07.27
  • Accepted : 2012.03.21
  • Published : 2012.05.31

Abstract

PURPOSE. To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS. Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS. Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION. Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.

Keywords

References

  1. van Waas MA. The influence of psychologic factors on patient satisfaction with complete dentures. J Prosthet Dent 1990;63: 545-8. https://doi.org/10.1016/0022-3913(90)90073-L
  2. Boerrigter EM, Geertman ME, Van Oort RP, Bouma J, Raghoebar GM, van Waas MA, van't Hof MA, Boering G, Kalk W. Patient satisfaction with implant-retained mandibular overdentures. A comparison with new complete dentures not retained by implants-a multicentre randomized clinical trial. Br J Oral Maxillofac Surg 1995;33:282-8. https://doi.org/10.1016/0266-4356(95)90038-1
  3. Fenn HRB, Liddlelow KP, Gimson AP. MacCregor AR. Clinical Dental prosthetics. 3rd ed. Butterworth-Heinemann Ltd; 1989. p. 290-304.
  4. Winkler S. Essentials of complete denture prosthodontics. 2nd ed. Ishiyaku Euro America; Philadelphia; 1994. p. 361-74.
  5. Basker RM, Davenport JC, Tomlin HR. Prosthetic treatment of the edentulous patient. 4th ed. Blackwell Co; 2002. p. 32-53.
  6. Zarb GA, Bolender CL, Eckert SE. Prosthodontic treatment for edentulous patients: complete dentures and implant-supported prostheses. 12th ed. Mosby; St. Louis; 2004. p. 123-59.
  7. Mericske-Stern R, Steinlin Schaffner T, Marti P, Geering AH. Peri-implant mucosal aspects of ITI implants supporting overdentures. A five-year longitudinal study. Clin Oral Implants Res 1994;5:9-18. https://doi.org/10.1034/j.1600-0501.1994.050102.x
  8. Morais JA, Heydecke G, Pawliuk J, Lund JP, Feine JS. The effects of mandibular two-implant overdentures on nutrition in elderly edentulous individuals. J Dent Res 2003;82:53-8. https://doi.org/10.1177/154405910308200112
  9. Budtz-J􀝚rgensen E. Effect of controlled oral hygiene in overdenture wearers: a 3-year study. Int J Prosthodont 1991;4:226-31.
  10. Visser A, Raghoebar GM, Meijer HJ, Batenburg RH, Vissink A. Mandibular overdentures supported by two or four endosseous implants. A 5-year prospective study. Clin Oral Implants Res 2005;16:19-25.
  11. Passamonti G, Kotrajarus P, Gheewalla RK, Clark RE, Maness WL. The effect of immediate dentures on maxillomandibular relations. J Prosthet Dent 1981;45:122-6. https://doi.org/10.1016/0022-3913(81)90326-7
  12. Schwartz IS, Morrow RM. Overdentures. Principles and procedures. Dent Clin North Am 1996;40:169-94.
  13. Palmer R, Palmer P, Howe L. Complications and maintenance. Br Dent J 1999;187:653-8.
  14. el Charkawi H. Immediate implant in fresh extraction socket of resected mandibular first molar: a preliminary clinical report. Implant Dent 2001;10:272-9. https://doi.org/10.1097/00008505-200110000-00011
  15. Lambadakis J, Karkazis HC. Changes in the mandibular rest position after removal of remaining teeth and insertion of complete dentures. J Prosthet Dent 1992;68:74-7. https://doi.org/10.1016/0022-3913(92)90289-M
  16. Saifuddin M, Miyamoto K, Ueda HM, Shikata N, Tanne K. A quantitative electromyographic analysis of masticatory muscle activity in usual daily life. Oral Dis 2001;7:94-100. https://doi.org/10.1034/j.1601-0825.2001.70205.x
  17. Slagter AP, Bosman F, van der Glas HW, van der Bilt A. Human jaw-elevator muscle activity and food comminution in the dentate and edentulous state. Arch Oral Biol 1993;38:195- 205. https://doi.org/10.1016/0003-9969(93)90028-K
  18. van Kampen FM, van der Bilt A, Cune MS, Bosman F. The influence of various attachment types in mandibular implantretained overdentures on maximum bite force and EMG. J Dent Res 2002;81:170-3. https://doi.org/10.1177/154405910208100305
  19. Prombonas A, Vlissidis D, Molyvdas P. The effect of altering the vertical dimension of occlusion on biting force. J Prosthet Dent 1994;71:139-43. https://doi.org/10.1016/0022-3913(94)90021-3
  20. Todd JE, Lader D. Adult Dental Health 1988: United, Kingdom. Social Survey Report SS1260. HMSO, London, 1991.
  21. Van Waas MA, Jonkman RE, Kalk W, Van't Hof MA, Plooij J, Van Os JH. Differences two years after tooth extraction in mandibular bone reduction in patients treated with immediate overdentures or with immediate complete dentures. J Dent Res 1993;72:1001-4. https://doi.org/10.1177/00220345930720060101
  22. Renner RP. The overdenture concept. Dent Clin North Am 1990;34:593-606.
  23. Langer Y, Langer A. Root-retained overdentures: Part IIManaging trauma between edentulous ridges and opposing dentition. J Prosthet Dent 1992;67:77-81. https://doi.org/10.1016/0022-3913(92)90054-E
  24. Nagasawa T, Okane H, Tsuru H. The role of the periodontal ligament in overdenture treatment. J Prosthet Dent 1979;42:12-6. https://doi.org/10.1016/0022-3913(79)90322-6
  25. Jemt T, Stalblad PA. The effect of chewing movements on changing mandibular complete dentures to osseointegrated overdentures. J Prosthet Dent 1986;55:357-61. https://doi.org/10.1016/0022-3913(86)90120-4
  26. Schmitt A, Zarb GA. The notion of implant-supported overdentures. J Prosthet Dent 1998;79:60-5. https://doi.org/10.1016/S0022-3913(98)70195-7
  27. Naert I, De Clercq M, Theuniers G, Schepers E. Overdentures supported by osseointegrated fixtures for the edentulous mandible: a 2.5-year report. Int J Oral Maxillofac Implants 1988l;3:191-6.
  28. Payne AG, Solomons YF. Mandibular implant-supported overdentures: a prospective evaluation of the burden of prosthodontic maintenance with 3 different attachment systems. Int J Prosthodont 2000;13:246-53.
  29. Karkazis HC. EMG activity of the masseter muscle in implant supported overdenture wearers during chewing of hard and soft food. J Oral Rehabil 2002;29:986-91. https://doi.org/10.1046/j.1365-2842.2002.00943.x
  30. Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants 1994;9:191-6.
  31. Huys LW. Replacement therapy and the immediate post-extraction dental implant. Implant Dent 2001;10:93-102. https://doi.org/10.1097/00008505-200104000-00004
  32. Castellon P, Yukna RA. Immediate dental implant placement in sockets augmented with HTR synthetic bone. Implant Dent 2004;13:42-8. https://doi.org/10.1097/01.ID.0000116451.04676.7B
  33. Payne AG, Solomons YF. The prosthodontic maintenance requirements of mandibular mucosa- and implant-supported overdentures: a review of the literature. Int J Prosthodont 2000; 13:238-43.
  34. Salama H, Salama M. The role of orthodontic extrusive remodeling in the enhancement of soft and hard tissue profiles prior to implant placement: a systematic approach to the management of extraction site defects. Int J Periodontics Restorative Dent 1993;13:312-33.
  35. Gelb DA. Immediate implant surgery: three-year retrospective evaluation of 50 consecutive cases. Int J Oral Maxillofac Implants 1993;8:388-99.
  36. Becker W, Dahlin C, Becker BE, Lekholm U, van Steenberghe D, Higuchi K, Kultje C. The use of e-PTFE barrier membranes for bone promotion around titanium implants placed into extraction sockets: a prospective multicenter study. Int J Oral Maxillofac Implants 1994;9:31-40.
  37. Brosh T, Persovski Z, Binderman I. Mechanical properties of bone-implant interface: an in vitro comparison of the parameters at placement and at 3 months. Int J Oral Maxillofac Implants 1995;10:729-35.
  38. Sahin S, Cehreli MC, Yalcin E. The influence of functional forces on the biomechanics of implant-supported prostheses-a review. J Dent 2002;30:271-82. https://doi.org/10.1016/S0300-5712(02)00065-9
  39. Brzoza D, Barrera N, Contasti G, Hernandez A. Predicting vertical dimension with cephalograms, for edentulous patients. Gerodontology 2005;22:98-103. https://doi.org/10.1111/j.1741-2358.2005.00060.x
  40. Gervais RO, Fitzsimmons GW, Thomas NR. Masseter and temporalis electromyographic activity in asymptomatic, subclinical, and temporomandibular joint dysfunction patients. Cranio 1989;7:52-7. https://doi.org/10.1080/08869634.1989.11678268
  41. Ferrario VF, Sforza C, D'Addona A, Miani A Jr. Reproducibility of electromyographic measures: a statistical analysis. J Oral Rehabil 1991;18:513-21. https://doi.org/10.1111/j.1365-2842.1991.tb00074.x
  42. Visser A, McCarroll RS, Naeije M. Masticatory muscle activity in different jaw relations during submaximal clenching efforts. J Dent Res 1992;71:372-9. https://doi.org/10.1177/00220345920710020501
  43. Carlson CR, Okeson JP, Falace DA, Nitz AJ, Curran SL, Anderson D. Comparison of psychologic and physiologic functioning between patients with masticatory muscle pain and matched controls. J Orofac Pain 1993;7:15-22.
  44. Carlson N, Moline D, Huber L, Jacobson J. Comparison of muscle activity between conventional and neuromuscular splints. J Prosthet Dent 1993;70:39-43. https://doi.org/10.1016/0022-3913(93)90035-M
  45. Gay T, Rendell J, Majoureau A, Maloney FT. Estimating human incisal bite forces from the electromyogram/bite-force function. Arch Oral Biol 1994;39:111-5. https://doi.org/10.1016/0003-9969(94)90105-8
  46. Turp JC, Schindler HJ, Pritsch M, Rong Q. Antero-posterior activity changes in the superficial masseter muscle after exposure to experimental pain. Eur J Oral Sci 2002;110:83-91. https://doi.org/10.1034/j.1600-0722.2002.11198.x
  47. Tallgren A, Holden S, Lang BR, Ash MM Jr. Jaw muscle activity in complete denture wearers-a longitudinal electromyographic study. J Prosthet Dent 1980;44:123-32. https://doi.org/10.1016/0022-3913(80)90122-5
  48. Daubechies I. Orthonormal bases of compactly supported wavelets. Comm Pure Appl Math 1988;41:909-96. https://doi.org/10.1002/cpa.3160410705
  49. Laurell L. Occlusal forces and chewing ability in dentitions with cross-arch bridges. Swed Dent J Suppl 1985;26:160.
  50. Clark GT, Carter MC, Beemsterboer PL. Analysis of electromyographic signals in human jaw closing muscles at various isometric force levels. Arch Oral Biol 1988;33:833-7. https://doi.org/10.1016/0003-9969(88)90108-2

Cited by

  1. Electromyography evaluation of masseter and temporalis, bite force, and quality of life in elderly patients during the adaptation of mandibular implant-supported overdentures vol.28, pp.10, 2016, https://doi.org/10.1111/clr.12980
  2. Premaxilla Stress Distribution and Bone Resorption Induced by Implant Overdenture and Conventional Denture pp.1059941X, 2018, https://doi.org/10.1111/jopr.12954
  3. Digital Denture Fabrication: A Technical Note vol.11, pp.17, 2012, https://doi.org/10.3390/app11178093