• 제목/요약/키워드: resonance evaluation

검색결과 834건 처리시간 0.026초

자기공명영상장치의 신호대 잡음비와 영상평가 (Evaluation of Signal to Noise Ratio and Image of Magnetic Resonance Imaging)

  • 이윤;오창현;안창범;이흥규
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.169-172
    • /
    • 1996
  • In this paper, we present the evaluation of signal to noise ratio(SNR) and images of Magnetic resonance imaging system which is underdevelopement. For the evaluation of such parameters, we used two different phantoms, one for SNR and image homogeneity, and the other is for the slice thickness measurement. Further, comparison with other leading MR systems may be needed for the better image quality assessment.

  • PDF

1.5T 자기공명영상을 이용한 물리적 영상 특성에 대한 연구 (Study on the Physical Imaging Characteristics by Using Magnetic Resonance Imaging 1.5T)

  • 민정환;정회원;한지현;이시내;박장호;김기원;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.329-334
    • /
    • 2019
  • This study was purpose to quantitative evaluation of noise power spectrum(NPS) and studied the quantitative evaluation and characteristics of modulation transfer function(MTF) by obtain the optimal edge image by using Coil in magnetic resonance imaging(MRI) equipment through Fujita theory using edge method. The MRI equipment was used (Tim AVANTO 1.5T, Siemense healthcare system, Germany) and the head matrix coil were 12channels(elements) receive coil. The NPS results of showed the best value of 0.004 based on the T2 Nyquist frequency of $1.0mm^{-1}$, and the MTF results of showed that the T1 and T2 values were generally better than the T1 CE and T1 CE FC values. The characteristics of this study were to explain the characteristic method of image quality evaluation in general. To present the quantitative evaluation process and results in the evaluation of MRI image characteristics in radiology.

Magnetic Resonance Imaging and Ultrasonographic Evaluation of Canine Tarsus

  • Soomin Park;Sang-hwa Ryu;Jae-gwan Heo;Eun-jee Kim;Jihye Choi;Junghee Yoon
    • 한국임상수의학회지
    • /
    • 제41권2호
    • /
    • pp.79-87
    • /
    • 2024
  • The tarsus in dogs has a complex structure that makes its evaluation relatively challenging. Because an accurate diagnosis of the tarsus is difficult through basic examinations alone, imaging tests are essential. Previous studies have explored the anatomical and radiological features of the canine tarsus using several imaging modalities. However, the imaging utility of the tarsus across different modalities has not been thoroughly evaluated. This study aimed to visualize the tarsal structures using magnetic resonance imaging (MRI) and ultrasonography, compare their utility, and propose suitable imaging modalities and conditions for evaluating specific tarsal structures. Magnetic resonance imaging and ultrasound scans of the tarsus of four healthy dogs were performed, and two observers rated the utility of each image on a five-point scale. Although MRI is more beneficial for assessing the tarsal structures than ultrasound, ultrasound also appears clinically useful for evaluating the cranial tibialis muscle, deep digital flexor tendon, subcutaneous fat, joint space, and superficial digital flexor tendon. In addition, each structure of interest can be evaluated for optimal visibility using specific ultrasound sections, MRI sequences, and planes. In veterinary clinical practice, an initial assessment using ultrasound imaging with optimal visibility is required and if further evaluation is necessary, MRI examinations with optimal MRI sequences and planes can be performed.

POINTWISE CROSS-SECTION-BASED ON-THE-FLY RESONANCE INTERFERENCE TREATMENT WITH INTERMEDIATE RESONANCE APPROXIMATION

  • BACHA, MEER;JOO, HAN GYU
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.791-803
    • /
    • 2015
  • The effective cross sections (XSs) in the direct whole core calculation code nTRACER are evaluated by the equivalence theory-based resonance-integral-table method using the WIMS-based library as an alternative to the subgroup method. The background XSs, as well as the Dancoff correction factors, were evaluated by the enhanced neutron-current method. A method, with pointwise microscopic XSs on a union-lethargy grid, was used for the generation of resonance-interference factors (RIFs) for mixed resonant absorbers. This method was modified by the intermediate-resonance approximation by replacing the potential XSs for the non-absorbing moderator nuclides with the background XSs and neglecting the resonance-elastic scattering. The resonance-escape probability was implemented to incorporate the energy self-shielding effect in the spectrum. The XSs were improved using the proposed method as compared to the narrow resonance infinite massbased method. The RIFs were improved by 1% in $^{235}U$, 7% in $^{239}Pu$, and >2% in $^{240}Pu$. To account for thermal feedback, a new feature was incorporated with the interpolation of pre-generated RIFs at the multigroup level and the results compared with the conventional resonance-interference model. This method provided adequate results in terms of XSs and k-eff. The results were verified first by the comparison of RIFs with the exact RIFs, and then comparing the XSs with the McCARD calculations for the homogeneous configurations, with burned fuel containing a mixture of resonant nuclides at different burnups and temperatures. The RIFs and XSs for the mixture showed good agreement, which verified the accuracy of the RIF evaluation using the proposed method. The method was then verified by comparing the XSs for the virtual environment for reactor applicationbenchmark pin-cell problem, as well as the heterogeneous pin cell containing burned fuel with McCARD. The method works well for homogeneous, as well as heterogeneous configurations.

DESIGN GUIDELINE FOR THE IMPROVEMENT OF DYNAMIC COMFORT OF A VEHICLE SEAT AND ITS APPLICATION

  • JANG H.-K.
    • International Journal of Automotive Technology
    • /
    • 제6권4호
    • /
    • pp.383-390
    • /
    • 2005
  • This study proposes an innovative design guideline to assist the evaluation and improvement of the dynamic comfort of vehicle seating. The existing evaluation method for the comfort of vehicle seating was investigated to broach problems in evaluation. It was found that the currently existing evaluation method employs the resonance frequency of the vibration system composed of the seat and the human body and the maximum vibration transmissibility. This study proposes a design guideline aimed at the enhancement of vibration transmission characteristics above the resonance range, particularly within the range of 10-18 Hz. In order to meet this guideline, a seat was constructed out of foam having a low damping coefficient. It was then installed in a vehicle for a driving test. The driving test confirmed the improvement of the dynamic comfort of the seat. The result of evaluation of the improved seat using the SEAT index, an industry standard widely used to evaluate the dynamic comfort of a seat considering the perceptivity characteristics of the human body, showed that the perceptive vibration transmission had reduced by more than $11\%$. The effect of the modification of seat foam was also verified through a subjective assessment of dynamic comfort of the seats.

Pediatric Magnetic Resonance Enterography: Focused on Crohn's Disease

  • Lee, So Mi;Kim, Woo Sun;Choi, Young Hun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제18권3호
    • /
    • pp.149-159
    • /
    • 2015
  • Crohn's disease is a chronic idiopathic inflammatory disease of the intestines characterized by frequent relapse and remission. It often develops in children and adolescents, who are vulnerable to repeated exposure to ionizing radiations. Magnetic resonance enterography (MRE) is an increasingly important radiation-free imaging modality that is used to evaluate pediatric patients with Crohn's disease. MRE can evaluate extraluminal and extraintestinal abnormalities as well as the status of the bowel wall. In addition, MRE has an advantage in the evaluation of the small bowel involvement. MRE can be used for the initial diagnosis of Crohn's disease, and can aid in the assessment of disease activity and complications such as penetrating and fibrostenotic diseases. The aims of this article are to review the MRE technique for obtaining diagnostic and high-quality images and to discuss interpretations of imaging findings in patients with Crohn's disease.

Characteristics of New Estrogen Biosensor Employing Taste Principles

  • Kwon, Soon-Bae;Lee, Cil-Han;Kim, Kyung-Nyun
    • International Journal of Oral Biology
    • /
    • 제36권2호
    • /
    • pp.103-108
    • /
    • 2011
  • Measurement of estrogen concentration in bio-samples are very important for differential diagnosis of various disease or evaluation of health status. However, it is difficult to collect immediate data of estrogen concentration because they are measured by radioimmunoassay or chromatography which need time- and cost-consuming sample pre-treatment. This study was performed for development of new estrogen biosensor employing taste principles, and for evaluation of cross reactivity between various steroid hormones. Gene sequence of ligand binding domain of ${\alpha}$-human estrogen receptor (amino acid 302-553; hER-LBD) was cloned from human breast cancer cell line. The proteins of hER-LBD were produced by T7-E.coli expression system, and isolated by chromatography. hER-LBD were coated on the gold plated quartz crystal (AT-cut 9MHz), and resonance frequencies were measured by universal frequency counter. Estradiol, progesterone, testosterone, and aldosterone were used for cross reactivity of the hER-LBD. We also monitored influences of pH change in resonance frequency. The resonance frequencies of hER-LBD coated quartz crystal were decreased during increase of estrogen concentration from $15 \;{\mu}g/mL$ to $50\;{\mu}g/mL$. However, similar steroid hormones, progesterone and aldosterone, did not elicit the change in resonance frequency. Testosterone evoke weak change in resonance frequency. The new estrogen biosensor was more sensitive in pH 7.2 than in pH 7.6. These results suggest that hER-LBD coated quartz crystal biosensor is a probable estrogen biosensor.