Abstract
This study was purpose to quantitative evaluation of noise power spectrum(NPS) and studied the quantitative evaluation and characteristics of modulation transfer function(MTF) by obtain the optimal edge image by using Coil in magnetic resonance imaging(MRI) equipment through Fujita theory using edge method. The MRI equipment was used (Tim AVANTO 1.5T, Siemense healthcare system, Germany) and the head matrix coil were 12channels(elements) receive coil. The NPS results of showed the best value of 0.004 based on the T2 Nyquist frequency of $1.0mm^{-1}$, and the MTF results of showed that the T1 and T2 values were generally better than the T1 CE and T1 CE FC values. The characteristics of this study were to explain the characteristic method of image quality evaluation in general. To present the quantitative evaluation process and results in the evaluation of MRI image characteristics in radiology.
Keywords
Magnetic Resonance Imaging; Modulation Transfer Function; Noise Power Spectrum; Edge Method; Fujita Method;
Citations & Related Records
Times Cited By KSCI : 8  (Citation Analysis)
연도 인용수 순위
1 Hahm HK. The study on the subject development of MRI image quality evaluation Department of Radiology [master's thesis]. Perth: Eulji University; 2008.
2 Miyati T, Fujita H, Kasuga T, et al. Measurements of MTF and SNR(f) using a subtraction method im MRI. Physics in Medicine and Biology. 2002;47:2961-72.   DOI
3 Steckner MC, Drost DJ, Prato FS. Computing the modulation transfer function of a magnetic resonance imager. Med. Phys. 1994;21:483-9.   DOI
4 Kim KW, Jeong HW, Min JW, et al. Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom. Journal of Radiological Science and Technology. 2016;39(2):193-8.   DOI
5 Min JW, Jeong HW, Kim KW, et al. Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy. Journal of Radiological Science and Technology. 2015;38(4):451-61.   DOI
6 Kim KW, Jeong HW, Min JW, et al. Evaluation of the Performance Characteristic for Mammography by Using Edge device. Journal of Radiological Science and Technology. 2016;39(3):415-20.   DOI
7 Kim KW, Jeong HW, Min JW, et al. Measurement of Image Quality According to the Time of Computed Radiography System. Journal of Radiological Science and Technology. 2015;38(4):365-74.   DOI
8 Jeong HW, Min JW, Kim JM, et al. Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System. Journal of Radiological Science and Technology. 2012;35(2):109-17.
9 Jeong HW, Min JW, Kim JM, et al. Investigation of Physical Imaging Properties in Various Digital Radiography System. Journal of Radiological Science and Technology. 2017;40(3):363-70.   DOI
10 Min JW, Jeong HW. Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography. Journal of Radiological Science and Technology. 2019;42(4):259-63.   DOI
11 Min JW, Jeong HW, Kim KW, et al. Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography. Journal of Radiological Science and Technology. 2018;41(5):457-62.   DOI
12 Mohapatra SM, Turley JD, Prince JR, et al. Transfer function measurement and analysis for magnetic resonance imager. Med. Phys. 1991;18(6):1141-44.   DOI
13 EEC Concerted Research Project. Identification and characterization of biological tissues by NMR. Concerted Research Project of the European Economic Community: IV. Protocols and test objects for the assessment of MRI equipment. Magn. Reson. Imaging 1988;6:195-9.   DOI
14 Choi KW, Kim YS, Son SY, et al. The usefulness of the contrast agent high in gadolinium for the contrast-enhanced magnetic resonance hip arthrography. Journal of the Korea Academia Industrial. 2013;14(11):5682-8.   DOI
15 Fujita H, Tasai DY, Itoh T, et al., A simple method for determining the modulation transfer function in digital radiography. IEEE Trans Med Imaging. 1992;11(1):34-9.   DOI
16 Samei E, Flynn MJ, Reimann DA, et al. A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Medical Physics. 1998;25:102.   DOI
17 Greer PB, van Doorn T. Evaluation of an algorithm for the assessment of the MTF using an edge method. Medical Physics. 2000;27:2048.   DOI