• Title/Summary/Keyword: relative humidity of microclimate

Search Result 62, Processing Time 0.027 seconds

Assessment of Wear Comfort of Water-vapor-permeable (WVP) garments (투습방수의류의 착용쾌적성 평가)

  • Kang, In-Hyeng;Park, Hyo-Suk;Lee, Han-Sup
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.9
    • /
    • pp.928-939
    • /
    • 2012
  • This study evaluates wear comforts of water-vapor-permeable (WVP) garments through a measurement of various parameters such as skin and rectal temperatures, microclimate between skin and clothing, sweat rate, and subjective sensations (thermal, wet and comfort sensations) to correlate the physiological responses of the human body with its comfort feeling. Wear comfort during a specific exercise on a treadmill in a climatic chamber (temperature T = $20{\pm}0.5^{\circ}C$ and relative humidity H = $50{\pm}10%$) were studied using eight men wearing seven sportswear outfits (a long sleeve shirts and a long pants) made with seven different WVP fabrics. A comfort sensation was found to be highly correlated with skin T (p<.001), microclimate (T and H) between skin and clothing (p<.001) and sweat rate (p<.05). A regression model correlating comfort sensations and physiological responses obtained from wearer trials could be established: Y = 14.167 - 0.362 ${\times}$ X1 + 0.424 ${\times}$ X2 - 0.238 ${\times}$ X3 - 0.561 ${\times}$ X4 + 0.253 ${\times}$ X5 + 0.214 ${\times}$ X6 - 0.393 ${\times}$ X7 + 0.023 ${\times}$ X8 - 0.043 ${\times}$ X9. (Y = comfort sensation, X1 = forehead skin T, X2 = forearm skin T, X3 = hand skin T, X4 = thigh skin T, X5 = T of chest microclimate, X6 = T of thigh microclimate, X7 = chest sweat rate, X8 = H of back microclimate, X9 = H of thigh microclimate. The regression model obtained in this work can be used by manufacturers to objectively estimate the comfort sensation of sportswear before it is introduced to the consumer market. This study provides salient information to sportswear manufacturers and sportswear consumers.

Evaluation of Physiological Responses and Subjective Sensation in Different Sock Materials (양말 소재별 인체생리적 반응 및 주관적 감각평가)

  • 김칠순;정명희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.8
    • /
    • pp.1475-1483
    • /
    • 2001
  • The purpose of this study was to determine the physiological responses and subjective sensation according to fiber content of socks. Six female students participated in the wear trial test which was conducted in controled environmental chamber with 26${\pm}$1$^{\circ}C$ and 60${\times}$3%. R.H.SAS program was used for statistical analysis. The results of this study were as follows. Mean skin temperature was significantly different among three different socks. AWNP socks had the highest mean skin temperature and instep temperature. Also relative humidity in the microclimate of socks as well as heart rate were influenced by fiber content of socks, However, test of subjective sensation such as thermal, humid, comfort sensation showed that there was no significant difference among three different socks thermal sensation during the exercise and recovery period.

  • PDF

Effect of Scindapsus aureus and Syngonium podophyllum on the Improvement in Indoor Humidity by a Difference of Hydoroculture Volume Ratio and Pot Media (하이드로컬쳐 부피비와 화분용토에 따른 스킨답서스, 싱고늄의 실내습도 개선효과)

  • Ju, Jin-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.4
    • /
    • pp.94-99
    • /
    • 2009
  • The purpose of this study was to utilize hydroculture by the vital means of the improvement of indoor relative humidity. This experiment employed a search of the effect of Scindapsus aureus and Syngonium podophyllum that are generalized for hydroculture foliage plant by a difference of volume ratio, pot media and plants species. In the case of Scindapsus aureus, relative humidity was high for growth chamber in which plants presented as opposed to control growth chambers in which there were no plants. Although relative humidity was 25% in control chamber, there was an increase of 40% at a 2% volume ratio, 45% at a 3% volume ratio and 50% at a 5% volume ratio. The relative humidity of Syngonium podophyllum was 40% at a 2% volume ratio, 44% at a 3% volume ratio and 46% at a 5% volume ratio, while the control treatment was 25% relative humidity in hydroculture. Both the control treatment and hydroball pot in a hydroball container were high at first. As time progressed, artificial soil pots in water containers was similar when housed within the control chamber by about 45% relative humidity. Hydroball pots in water container had about 30% relative humidity. Ardisia pusilla of hydroball poIt in hydroball container had about 38% relative humidity.

Effects of Forest Restoration Methods and Stand Structure on Microclimate in Burned Forest Stand (산불 피해지 복원 방법이 임분 내 미세 기후에 미치는 영향)

  • Kim, Jeong Hwan;Lim, Joo-Hoon;Park, Chanwoo;Kwon, Jino;Choi, Hyung Tae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.3
    • /
    • pp.207-216
    • /
    • 2015
  • The study was conducted to determine the effects of forest restoration methods and stand structure on solar radiation, air temperature, relative humidity, soil temperature, and soil water content, based on volume, in forest stand after forest fire. The changes of the micro-climate elements in naturally and artificially restored forest after forest fire were measured in Goseong and Samcheok, Gangwon province. Pinus spp. were commonly appeared in ridges, barren lands or planted areas of the study sites while the other areas were dominated by Quercus spp. In the early stage, trees in the naturally regenerated site grow better than the trees in artificially rehabilitated site. However, the growth ratio rapidly decreased by time passed in natural regeneration area. The environmental conditions (solar radiation, air temperature, relative humidity, soil temperature and soil water content) were significantly different by the regions and the methods (p<.05). However, the coefficients of variations of the environmental conditions were not significantly different at 95% confidence level. As the coverage and tree height in crown layer increased, the relative humidity and soil water content were increased while the temperature and solar radiation were decreased. Especially, the relative humidity, solar radiation, and soil water content were clearly affected by the tree height and coverage ratio ($R^2$ means from 0.628 to 0.924). Even though the data should have collected at least more than 5 years in meteorological analysis, the two year results show some clear relationship between forest structure and microclimate elements.

Effects of Individual Sweating Response on Changes in Skin Blood Flow and Temperature Induced by Heat of Sorption Wearing Cotton Ensemble

  • Tanaka, Kaori;Hirata, Kozo
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.398-404
    • /
    • 2000
  • We examined the effect of individual sweating responses on thermoregulatory responses induced by heat of sorption, immediately after the onset of sweating. The present study consists of two experiments. In experiment 1, made of 100% cotton (C) and 100% polyester (P) clothing were exposed in the chamber at ambient temperature (Ta) of $27.2^{\circ}C$ and relative humidity (rh) raised from 50% to 95% at five different increase rates of environmental vapor pressure (VP). The increase rate of clothing surface temperature (Tcs), peak Tcs and peak time showed significant correlation with the increase rate of environmental VP in C-clothing (p<0.05). In experiment 2, seven female subjects were studied during leg water immersion ($35-41^{\circ}C$) for 70min in Ta of 27.2 and 50%rh. There were significant positive correlations in the increase rate of clothing microclimate VP vs. changes in Tcs, skin blood flow, mean skin temperature and mean body temperature (p<0.05). The present results showed that individual clothing microclimate VP had significant effects on thermoregulatory responses induced by heat of sorption wearing C ensembles.

  • PDF

Characterization of Odorant Compounds from Mechanical Aerated Pile Composting and Static Aerated Pile Composting

  • Kumari, Priyanka;Lee, Joonhee;Choi, Hong-Lim
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.4
    • /
    • pp.594-598
    • /
    • 2016
  • We studied airborne contaminants (airborne particulates and odorous compounds) emitted from compost facilities in South Korea. There are primarily two different types of composting systems operating in Korean farms, namely mechanical aerated pile composting (MAPC) and aerated static pile composting (SAPC). In this study, we analyzed various particulate matters (PM10, PM7, PM2.5, PM1, and total suspended particles), volatile organic compounds and ammonia, and correlated these airborne contaminants with microclimatic parameters, i.e., temperature and relative humidity. Most of the analyzed airborne particulates (PM7, PM2.5, and PM1) were detected in high concentration at SAPC facilities compered to MAPC; however these differences were statistically non-significant. Similarly, most of the odorants did not vary significantly between MAPC and SAPC facilities, except for dimethyl sulfide (DMS) and skatole. DMS concentrations were significantly higher in MAPC facilities, whereas skatole concentrations were significantly higher in SAPC facilities. The microclimate variables also did not vary significantly between MAPC and SAPC facilities, and did not correlate significantly with most of the airborne particles and odorous compounds, suggesting that microclimate variables did not influence their emission from compost facilities. These findings provide insight into the airborne contaminants that are emitted from compost facilities and the two different types of composting agitation systems.

Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change (기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구)

  • Yoon, Yong-Han;Kwon, Ki-Uk
    • Journal of Environmental Science International
    • /
    • v.27 no.12
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

Optimization of Growth Environment in the Enclosed Plant Production System Using Photosynthesis Efficiency Model (광합성효율 모델을 이용한 밀폐형 식물 생산시스템의 재배환경 최적화)

  • Kim Keesung;Kim Moon Ki;Nam Sang Woon
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.209-216
    • /
    • 2004
  • This study was aimed to assess the effects of microclimate factors on lettuce chlorophyll fluorescent responses and to develop an environment control system for plant growth by adopting a simple genetic algorithm. The photosynthetic responses measurements were repeated by changing one factor among six climatic factors at a time. The maximum Fv'/Fm' resulted when the ambient temperature was $21^{\circ}C,\;CO_2$ concentration range of 1,200 to 1,400 ppm, relative humidity of $68\%$, air current speed of $1.4m{\cdot}s^{-1}$, and the temperature of nutrient solution of $20^{\circ}C$. In PPF greater than $140{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, Fv'/Fm' values were decreased. To estimate the effects of combined microclimate factors on plant growth, a photosynthesis efficiency model was developed using principle component analysis for six microclimate factors. Predicted Fv'/Fm' values showed a good agreement to measured ones with an average error of $2.5\%$. In this study, a simple genetic algorithm was applied to the photosynthesis efficiency model for optimal environmental condition for lettuce growth. Air emperature of $22^{\circ}C$, root zone temperature of $19^{\circ}C,\;CO_2$ concentration of 1,400 ppm, air current speed of $1.0m{\cdot}s^{-1}$, PPF of $430{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and relative humidity of $65\%$ were obtained. It is feasible to control plant environment optimally in response to microclimate changes by using photosynthesis efficiency model combined with genetic algorithm.

Damage Factor Interpretation and Conservational Environment Assessment by Microclimatic Analysis of Hyeonpung Seokbinggo (Ice-storing Stone Warehouse), Korea (현풍석빙고의 미기후 분석을 통한 손상요인 해석과 보존환경 평가)

  • Kim, Ji-Young;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.385-395
    • /
    • 2010
  • This study aimed to identify weathering factors and to assess the conservation environment through microclimatic analysis of Hyeonpung Seokbinggo (ice-storing stone warehouse). The stone blocks inside Seokbinggo suffered crack, displacement, break-out, exfoliation, efflorescence, brown and black discoloration, and biological colonization. Biological colonization represented the maximum deterioration rate(24%) among those weathering forms. The indoor microclimate showed parallel patterns with outdoor one, but the indoor temperature and relative humidity ranged far narrower than outdoor and remained steady. The environmental characteristics resulted from blocking-out of outdoor heat by the closed entrance and surrounding microtopography. This prevented water condensation and freezing effects, so that it reduced physical deterioration of rock, and maximized ice-storing effect for long time. However, contrary to positive effect, extremely high relative humidity over 99% accelerated biological colonization inside the Seokbinggo.

Analysis of Microclimate and Conservation Environment of the Stone Buddha and Shrine in Unjusa Temple, Hwasun, Korea (화순 운주사 석조불감의 보존환경 및 미기상 분석)

  • Park, Sung-Mi;Lee, Chan-Hee;Lee, Myeong-Seong;Kim, Sa-Dug
    • Economic and Environmental Geology
    • /
    • v.42 no.1
    • /
    • pp.73-84
    • /
    • 2009
  • The stone Buddha and Shrine of Unjusa temple (Korean Treasure No. 797) at Hwasun formed in Koryo Dynasty is unique style which faces each other the back parts of south and north within the stone Shrine. The stone Buddha and Shrine is highly evaluated in historical, artistic and academic respects. But, the stone properties have been exposed in the open system various aspects of degradations weathered for a long time without specific protective facilities. To inquire into relative deterioration and environmental factor, air temperature and relative humidity of the stone Buddha and Shrine were monitored for a year of the indoor and outdoor, respectively. As a result, the temperature shows increase and decrease according to the seasons in the tendency to clear. While the relative humidity is high to keep all four seasons. Highly relative humidity environment induces dew condensation on the interior of stone Buddha and Shrine. The dew condensation is recorded at the spring, summer and winter season. The summer season is double the total of spring and winter season. In the case of summer, dew condensation is long time continued due to high temperature and relative humidity that is kept by more than nearly 100%. There is progress towards chemical weathering throughout dissolve rock properties and alteration on the rock surface. In the case of winter, dew condensation is not kept for a long time as summer. In the winter, which showing a below zero may add physical weathering throughout moisture that happen by dew condensation to repeat freezing and thawing. Therefore, the reduction plan of the relative humidity effect on dew condensation should be prepared.