• Title/Summary/Keyword: reinforcing rebar

Search Result 140, Processing Time 0.023 seconds

Analytical study on the Bond Behavior of FRP Rebar in Concrete (FRP Rebar의 부착거동 해석)

  • You Young-Jun;Park Young-Hwan;Park Ji-Sun;You Young-Chan;Kim Hyeong-Yeol;Kim Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.636-639
    • /
    • 2004
  • Reinforced concrete structures have been used for a long time. However, corrosion problem in reinforcing steel is inevitable, which results in the degradation of performance and the shortening of the life of structures. To overcome such problems, FRP(Fiber Reinforced Polymer) rebars have been developed. Due to their corrosion resistance and their superior mechanical properties, FRP rebars are increasingly applied to concrete structures in other countries. To obtain the composite action between FRP rebars and concrete, sufficient bond between two materials must be secured. But, the behavior of FRP rebars is different from that of steel rebars. Therefore, it is necessary to understand and develop the proper bond mechanism of FRP rebars to use them in concrete structures. This paper presents analytical results to investigate the bond-slip relationship between FRP rebars and concrete based on pull out tests.

  • PDF

Evaluation on the Durability of RC Structure Covered Creek for Road Vehicle (철근콘크리트 복개구조물의 내구성 평가)

  • 문한영;김성수;김홍삼;안기용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.789-792
    • /
    • 1999
  • Reinforced concrete structures covered creek for road vehicle located in urban areas have been experiencing corrosion of concrete and reinforcing steel caused by $H_2S$ gases generated by anaerobic bacterial. H2S gases react with oxygen and water to form sulfuric acid ($H_2SO_4$). This acid chemically attacks concrete, and sulfate ions penetrate into the concrete, causing rebar corrosion. In this work, to determine the conditions of RC culvert boxes which were constructed in the 1970s, various tests were conducted, including carbonation depth, compressive strength, half-cell potential measurements, and XRD analyses. Results indicated that the concrete deterioration was caused by sulfate attack and rebar corrosion. This paper discusses the evaluation on the durability of reinforced concrete structures covered creek for road vehicle.

  • PDF

Bond Characteristics of Glass Fiber Reinforced Polymer Rebar according to the Bar Location (GFRP 보강근의 단면 위치에 따른 부착특성)

  • Park, Ji-Sun;Park, Young-Hwan;You, Young-Jun;Hwang, Geum-Sic;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.197-200
    • /
    • 2006
  • The bond characteristics of three different types of glass fiber reinforced polymer(GFRP) reinforcing bars with different surface deformations were studied experimentally. Each specimen consisted of a concrete prism, 150 by 150 mm on each edge, with the longer axis in the vertical direction. Two rebars were embedded in each specimen, perpendicular to the longer axis and parallel to and equidistant from the sides of the prism. In vertical direction, one rebar was located at 75 mm from the bottom of the prism, and the other 225 mm from the bottom. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the recommendations of CSA Standard S806-02.It was found that the bottom reinforcements showed higher bond stress than that of the top rebars.

  • PDF

Comparison of Pure Reinforcement Quantity to Development & Splice Reinforcement Quantity using High-strength Reinforcing Bars (고강도 철근 사용에 따른 순수 철근량에 대한 정착 및 이음 철근량 비교)

  • Cho, Seung-Ho;Na, Seung-Uk;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.72-80
    • /
    • 2018
  • Whilst it is common to construct high-rise buildings and long-span structures in the construction and building industry, there might be a number of problems such as excessive re-bars arrangement, deterioration of concrete quality, unnecessary quantity take-off and so forth. As these types of buildings and structures are getting more popular, it is widespread to apply high-strength materials such as high-strength concrete and re-bars to sustain durability and stability. This research aims to investigate the effectiveness of the high-strength reinforcing bars on the underground parking in a rigid-frame structure. In this study, the reinforcing bars with different yield strength were applied to corroborate the usefulness and practicability of the high-strength re-bars on the underground parking in a rigid-frame structure. The test results show that the quantity of reinforcement bars is lowered, as the yield strength of the re-bars are grown in general. However, the quantity of reinforcement bars on the development and splice has a tendency to increase slightly. Despite of the increase of the development and splice, the total quantity of reinforcing bars was reduced since the increasing ration of the pure quantity is higher than the development and splice. Base on the test results, it would be possible to achieve the reduction of reinforcing bars arrangement and lowering the amount of work to be done during a construction phase. Moreover, the reduced amount of bar arrangement will make it possible to improve workability and constructability of reinforced concrete structures. Ultimately, we will be able to attain improved quality and efficiency of construction using reinforced concrete.

Creep Behavior of Pultruded Ribbed GFRP Rebar and GFRP Reinforced Concrete Member (인발성형된 이형 GFRP 보강근과 GFRP 보강 콘크리트 부재의 크리프 거동)

  • You, Young-Jun;Park, Young-Hwan;Kim, Hyung-Yeol;Choi, Jin-Won;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.187-194
    • /
    • 2013
  • Fiber reinforced polymer (FRP) has been gathering interest from designers and engineers for its possible usage as a replacement reinforcement of a steel reinforcing bar due to its advantageous characteristics such as high tensile strength, non-corrosive material, etc. Since it is manufactured with various contents ratios, fiber types, and shapes without any general specification, test results for concrete members reinforced with these FRP reinforcing bars could not be systematically used. Moreover, since investigations for FRP reinforced members have mainly focused on short-term behavior, the purpose of this study is to evaluate long-term behaviors of glass FRP (GFRP) reinforcing bar and concrete beams reinforced with GFRP. In this paper, test results of tensile and bond performance of GFRP reinforcing bar and creep behavior are presented. In the creep tests, results showed that 100 years of service time can be secured when sustained load level is below 55% of tensile strength of GFRP reinforcing bar. A modification factor of 0.73 used to calculate long-term deflection of GFRP reinforced beams was acquired from the creep tests for GFRP reinforced concrete beams. It is expected that these test results would give more useful information for design of FRP reinforced members.

Investigation for the Efficiency in Flexural Design of CFRP Bar-Reinforced Concrete Slab (CFRP 보강근 보강 콘크리트 슬래브 휨설계의 효율성에 관한 연구)

  • Kang, Su-Tae;Yang, Eun-Ik;Choi, Myung-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.81-90
    • /
    • 2022
  • In this study, for one-way concrete slabs, the flexural strength, deflection, and crack width according to the amount of reinforcing bars were compared for the cases of using steel reinforcing bars and CFRP reinforcing bars. Critical performance dominating the flexural design was investigated and how to design the CFRP-reinforced concrete slab with efficiency was also discussed. It was found that CFRP-reinforced concrete slabs could achieve greater design flexural strength with the same amount of reinforcing bars compared to those using steel rebar, while deflection and crack width were relatively much larger. In concrete slabs using CFRP reinforcing bars, it was confirmed that the maximum crack width acts as a dominant factor in the design. For more efficient flexural design, it is necessary to mitigate the allowable crack width to 0.7 mm and to apply smaller diameter reinforcing bars to control the crack width.

Study of Development on Mechanical Connection of Reinforcing Bars (With Study of Tensile Force) (철근 커플러 개발에 관한 연구 (인장력 시험을 중심으로))

  • 최희복;김광희;강경인
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.37-41
    • /
    • 2002
  • Lap splice is used in building construction up to recently. As buildings become higher and larger, the use of high tensile bar is increasing due to increasing in the use of high compression concrete. However the using of high tensile bar in lap splice causes eccentricity and difficulty in placing of concrete inside the form, therefore not allowing enough intervening material. Various mechanical connection are being developed but the coupler of today needs either a secondary intervening material or secondary processing that consumes much time. Therefore a coupler, needing neither a secondary intervening material nor secondary processing, was made in this study which lead to following results. (1) Breaking occurred in all experimented rebar. (2) Acquirement of tension exceeding the standard requirement. (3) Acquirement of elongation percentage within the standard requirement.

  • PDF

Tensile Properties and Testing Method for Glass Fiber Reinforced Polymer Reinforcing bar (GFRP Rebar의 인장특성 및 시험법에 관한 연구)

  • Park Ji-Sun;You Young-Chan;Park Young-Hwan;Choi Ki-Sun;You Young-Jun;Kim Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.172-175
    • /
    • 2004
  • This study is to investigate the tensile properties of glass fiber reinforced polymer(GFRP) reinforcing bars with various kinds of anchor systems experimentally. Three types of anchor systems were examined: resin sleeve anchor adopted by CSA Standard, metal overlay anchor by ASTM Standards and wedge anchor normally used in prestressing tendons. Also, three different types of GFRP bars with different surface deformations were tested in this study. All test procedures including specimens preparation, test apparatus and measuring devices were made according to the recommendations of CSA Standard S806-02. From the test results, it was found that the highest tensile strength of GFRP bar was developed by resin sleeve anchor, and tensile strength of GFRP bar with CSA anchor system is $10\%$ higher than that with ASTM anchor system in the case of sand-coated GFRP bar.

  • PDF

Effect of degree of corrosion on the mechanical properties of rebar (철근부식정도가 철근의 역학적 특성에 미치는 영향)

  • Cheong, Hai-Moon;Lee, Chan-Young;Ahn, Tas-Song;Tae, Sung-Ho;Lee, Han-Seung;Kang, In-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.257-260
    • /
    • 2006
  • This paper reports results of a study conducted to assess the effect of degree of corrosion of reinforcing steel bar on their mechanical properties. Reinforcing steel bars, 13mm in diameter, that were corroded by electrically accelerated corrosion method in concrete specimens were removed and tested in tension. Results indicated that the level of reinforcement corrosion influenced yield point, the tensile strength and elongation of steel bars.

  • PDF

Influence of Steel Bar on Ultrasonic Velocity in Concrete (콘크리트 속의 철근이 초음파 속도에 미치는 영향)

  • Kim, Do-Hyun;Rhim, Hong-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.122-123
    • /
    • 2014
  • Measurement of the strength of concrete is an important indicator of the safety of the fresh as well as old concrete structures. It is possible to evaluate the strength of the concrete by means of an ultrasonic velocity method which is a kind of non-destructive inspection method for safety diagnostic evaluation of the building structures with aging. Steel embedded in the concrete and age of the concrete may affect ultrasonic pulse velocity. In order to accurately assess the strength of the concrete, it is necessary to understand rebar embedded in the concrete, steel shapes in various forms which effect ultrasonic pulse velocity. In this study, by measuring the velocity of ultrasonic waves generated when the waves pass through the ultrasonic pulse in a direction perpendicular to the reinforcing bars embedded in concrete, the effect of reinforcing bars on ultrasonic velocity accurately was verified and used to estimate the strength of the concrete.

  • PDF