• Title/Summary/Keyword: regular branch

Search Result 63, Processing Time 0.022 seconds

A Forward-Integrated Buck DC-DC Converter with Low Voltage Stress for High Step-Down Applications

  • Adivi, Maedeh Ghanbari;Yazdani, Mohammad Rouhollah
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.356-363
    • /
    • 2018
  • The combination of a buck converter and a forward converter can be considered to accomplish a high step-down non-isolated converter. To decrease the insufficient step-down ratio of a regular buck converter and to distribute switch voltage stress, a forward-integrated buck (FIB) converter is proposed in this paper. The proposed interleaved DC-DC converter provides an additional step-down gain with the help of a forward converter. In addition to its simple structure, the transformer flux reset problem is solved and an additional magnetic core reset winding is not required. The operational principle and an analysis of the proposed FIB converter are presented and verified by experimental results obtained with a 240 W, 150 V/24 V prototype.

Study of the Shock Wave Propagating through a Branched Pipe Bend (분지관을 전파하는 약한 충격파에 관한 수치해석적 연구)

  • Kim Hyun-Sub;Szwaba Ryszard;Kim Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.165-168
    • /
    • 2002
  • This paper describes the dynamics of the weak shock wave propagating inside some kinds of branched pipe bends. Computations are carried out by solving the two-dimensional, compressible, unsteady Euler Equations. The second-order TVD(Total Variation Diminishing) scheme is employed to discretize the governing equations. For computations, two types of branched pipe($90^{\circ}$ branch,$45^{\circ}$ branch) with a diameter of D are used. The incident normal shock wave is assumed at D upstream of the pipe bend entrance, and its Mach number is changed between 1.1 and 2.4. The flow fields are numerically visualized by using the pressure contours and computed schlieren images. The comparison with the experimental data performed for the purpose of validation of computational work. Reflection and diffraction of the propagating shock wave are clarified. The present computations predicted the experimented flow field with a good accuracy.

  • PDF

Design of Millimeterwave Branch-Line Coupler Using Flip-Chip Technology (플립 칩 기술을 이용한 밀리미터파 대역 브랜치라인 커플러의 설계)

  • Yoon, Ho-Sung;Lee, Hai-Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.1-5
    • /
    • 1999
  • In this paper, we proposed a novel branch-line coupler using filp-chip technology. The proposed coupler consists of CPW and inverted microstrip. The CPW is on the GaAs flip-chip substrate, and the inverted microstrip is on the alumina main substrate. The ground plane of the CPW is used as a ground plane of the inverted microstrip. And both the transmission lines are connected by solder bump with each other. The characteristics of thisstructure was calculated by FDTD method. The S21, S31 are -3dB and the phase difference is $90^{\circ}$. The calculated characteristics are the same as those of the regular branch-line coupler. This structure can be applied for various kinds of devices using flipchip technology.

  • PDF

Mathematical modeling of humidification process by means of hollow fiber membrane contactor

  • Marjani, Azam;Baghdadi, Ali;Ghadiri, Mehdi
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.297-311
    • /
    • 2016
  • Modeling and simulation of air humidification by hollow fiber membrane contactors are investigated in the current study. A computational fluid dynamic model was developed by solving the k-epsilon turbulence 2D Navier-Stokes equations as well as mass conservation equations for steady-state conditions in membrane contactors. Finite element method is used for the study of the air humidification under different operating conditions, with a focus on the humidity density, total mass transfer flux and velocity field. There has been good agreement between simulation results and experimental data obtained from literature. It is found that the enhancement of air stream decreases the outlet humidity from 0.392 to 0.340 (module 1) and from 0.467 to 0.337 (module 2). The results also indicated that there has been an increase in air velocity in the narrow space of shell side compared with air velocity wide space of shell side. Also, irregular arrangement has lower dead zones than regular arrangement which leads to higher water flux.

Multi-block Technique for a duct flow with multiple outlets (다출구 덕트 유동 해석을 위한 복합 격자망 해석방법의 제안)

  • Jeon,Yong-Deok;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1416-1425
    • /
    • 1996
  • A numerical method has been proposed to predict 3-dimensional flow in a duct system with multiple outlets. For the duct system, it is supposed that the pressure values are given at multiple outlets while the velocity profile is given at a inlet. To maintain the continuity of pressure distribution between main and branch duct, present method allows that the pressure value taken from analysis of branch duct can be converted to the main duct analysis. The result from present method which can handle the pressure boundary condition closely coincided with that from regular method which can handle the velocity boundary condition only. Furthermore the flow distribution from present method showed good agreement with that from the single block method. From the comparison of the present method with the total pressure method used for engineering duct design, 13% of discrepancy in pressure loss was shown between the main duct inlet and the branch duct outlet.

Analysis of the PN diode circuit under the transient condition with 2-dimensional mixed mode device-circuit simulator (2차원 혼합모드 소자-회로 시뮬레이터에 의한 PN 다이오드 회로의 과도상태 해석)

  • 이원호;이은구;김태한;김철성
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.359-362
    • /
    • 1998
  • 2차원 혼합 모드 소자-회로 시뮬레이터를 이용한 과도상태 해석의 알고리즘을 제시한다. 1변수 muller 및 regular falsi법을 회로의 절점 전압과 분기(branch) 전류를 계산하는데 적용하였다. 제안된 알고리즘의 정확도와 유호성을 검증하기 위해 PN 다이오드의 양극(anode)에 저항이 직렬로 연결된 회로의 모의실험을 수행한 결과, MEDICI의 모의실험 결과에 비해 과도상태에서 전류 및 전압 특성은 각각 0.06%, 0.2% 오차 범위 한도 내에서 일치함을 보였다.

  • PDF

Experimental Study of flash point determination for Alcohols & Aromatic Compounds. (가연성 액체의 인화점 추정에 관한 실험적 연구)

  • 최세환;김광일
    • Fire Science and Engineering
    • /
    • v.7 no.2
    • /
    • pp.24-28
    • /
    • 1993
  • The flash point for flammable liquids (alcohol, aromatic compounds) were measured by Penskt-Martens's measuring apparatus with closed cup. As a result, it was observed that the flash points had the regular tendency according to the carbon number and the molecular structure. Consequently, the flash point for the alcohols were increased in proportion to the increase of the carbon number and branch number. The differences between the literature and experimental data are 14.6% for the relative error and 3.46$^{\circ}C$ in average for the measuring temperature.

  • PDF

Survey of mastitis management and incidence of mastitis in high somatic cell count of bulk milk at dairy farms in the Gyeongnam (경남지역의 체세포수 문제 목장에서의 젖소 유방염 관리실태 및 발생양상 조사)

  • Kim, Seong-Eun;Hah, Do-Yun;Jang, Eun-Hee;Kwon, Hee-Nyung;Jo, Seong-Suk;Kwon, Young-Taek;Park, Dong-Yeop;Lee, Kuk-Cheon;Kim, Jong-Shu
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.4
    • /
    • pp.379-388
    • /
    • 2011
  • Survey of mastitis management and incidence of mastitis in the Gyeongnam was started in May to September 2009 to solve mastitis problem statistically valid data for use in estimating mastitis management, isolation and antimicrobial drug susceptibility in 30 dairy farms having over 350,000/ml somatic cell count. In investigation on recognition of farmer about bovine mastitis, the ratio of understanding of differences between infectious and environmental origin, understanding of correlation between superbacteria and using indiscriminate, necessity of pathogen identification, and necessity of antimicrobial sensitivity tests were 80.0%, 73.3%, 33.3%, and 53.3%, respectively. In survey of mastitis management type, regular california mastitis test (CMT), conducting CMT test and empirical self-treatment, when detecting suspected cows, were 30.0%, 40.0%, and 46.7%, respectively. Checking and cleaning pulsators biweekly, cleaning vacuum system and replacing liners every 3~6 month, and getting milking system checked by engineers showed 80.0%, 76.7%, and 76.7% in the questionnaires, respectively. In recognition of farmer about milking hygiene for prevention of bovine mastitis, using individual towels, separated milking (milking order of cows), and teat-dipping disinfection after milking exhibited 13.3%, 86.7%, and 93.3%, respectively. In conclusion, through the questionnaires and laboratory test, we suggest that recognition of farmer about management and incidence of mastitis was very low, thus systemic educational program and public relations about mastitis management were need for dairy farmers.

Characteristics of Heavy Metals in the Industrial Complex Area of Pocheon City (포천시 공단지역 미세먼지 중 중금속농도 특성)

  • Shin, Hyung-Soon;Jung, Yeon-Hoon;Kim, Jin-gil;Jung, Jong-Pil;Lee, Sang-Soo;You, Han-Jo;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.577-582
    • /
    • 2019
  • Objectives: The purpose of this survey was to assess the concentrations of heavy metals in the atmosphere of Pocheon City by measuring heavy metals in the industrial complex area and at the city air measuring station, and also to assess the degree of impact that the industrial area has on urban air quality. Methods: Sampling was carried out between February 2018 and November 2018 at two sites in the industrial complex and in the city air monitoring stations. Results: At the industrial complex in Pocheon City, air pollutant emitting businesses were emitting concentrations of fine dust (PM10) between 45 and 60 ㎍/㎥ higher than in the city air. The daily maximum concentrations of lead (Pb), manganese (Mn), and cadmium (Cd) in the industrial complex are below the WHO recommendation standard (annual average), and the impact on the urban atmosphere is judged to be insignificant. Three to five percent of fine dust (PM10) consists of metallic materials, and as the fine dust increased, metals were detected proportionally. Although cadmium (Cd) and beryllium (Be) were not detected in the city air in Pocheon and chromium (Cr), copper (Cu), and arsenic (As) were found to be 50 percent or less, it is deemed that copper (Cu) was detected at unusually high levels due to unknown air pollutants, which requires regular heavy metal measurement and cause verification. Conclusions: An analysis of the heavy metals in the industrial zone and the urban atmosphere in Pocheon City in this study showed that the linear relationship of heavy metals in the industrial zone, or the direct impact relationship, on the heavy metals in the urban atmosphere could not be estimated. The sampling device for equivalent assessment of particulate matter installed at air pollution monitoring stations is highly likely to be used for analysis of fine dust and heavy metals.

Psychosocial Factors and Health Behavior among Korean Adults: A Cross-sectional Study

  • Kye, Su-Yeon;Park, Kee-Ho
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.49-56
    • /
    • 2012
  • Objective: This study was an attempt to identify associations between health behavior, such as smoking, alcohol consumption, healthy diet, and physical activity, and psychosocial factors. Methods: This crosssectional study was conducted among 1,500 participants aged between 30 and 69 years, selected from a population-based database in October 2009 through multiple-stratified random sampling. Information was collected about the participants' smoking and drinking habits, dietary behavior, level of physical activity, stress, coping strategies, impulsiveness, personality, social support, sense of coherence, self-efficacy, health communication, and sociodemographics. Results: Agreeableness, as a personality trait, was negatively associated with smoking and a healthy diet, while extraversion was positively associated with drinking. The tendency to consume a healthy diet decreased in individuals with perceived higher stress, whereas it increased in individuals who had access to greater social support. Self-efficacy was found to be a strong predictor of all health behaviors. Provider-patient communication and physical environment were important factors in promoting positive healthy behavior, such as consumption of a healthy diet and taking regular exercise. Conclusions: Psychosocial factors influence individuals' smoking and drinking habits, dietary intake, and exercise patterns.