• 제목/요약/키워드: regenerative burner

검색결과 16건 처리시간 0.021초

에너지 절약 및 이산화탄소 포집을 위한 축열식 순산소 연소로 개발 (Energy Saving and Development of an Industrial Regenerative Oxy-Fuel Combustion Furnace for CO2 Capture)

  • 오정석;노동순;이대근;홍성국;양제복;고창복;이은경
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.121-122
    • /
    • 2013
  • In recent years, the usage of fossil fuels has caused problems of climate change and global warming. Because the combustion of fossil fuels is related to the production of greenhouse gases ($CO_2$, $CH_4$, etc.), new technology in the field of combustion is needed in order to handle the crisis of climate change and the global warming. As one of the efforts to reduce the emission of greenhouse gases, the concept of regenerative oxy-fuel combustion for energy efficiency and carbon capture was suggested, In the current study, the development of an industrial regenerative oxy-fuel combustion furnace was introduced, which has been being performed at Korea Institute of Energy Research (KIER).

  • PDF

소형 축열식 복사관 버너시스템용 축열기 설계 및 성능평가 (Design and Estimation of Performance of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner)

  • 조한창;조길원;이용국
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2004년도 춘계 학술발표회 논문집
    • /
    • pp.171-176
    • /
    • 2004
  • 열처리로에 적용되는 소형 축열식 복사관 버너시스템에 사용될 축열기를 설계하고 그 성능을 평가하였다. 좁은 튜브간 간격을 갖는 U형 복사관에 축열기를 적용하기 위하여 상하단 단면적이 다른 축열기를 설계, 적용하였다. 구형축열체를 사용하는 2만kcal/hr급 축열기 설계에는 기존에 개발된 축열기 해석코드를 이용하였다. 실제 시스템에 적용하여 축열기 전후단의 온도 및 압력을 실시간으로 측정하였다. 그 결과를 축열기 해석코드로부터 얻은 배가스의 배출온도와 공기의 예열온도를 비교하였다. 이론적으로 예상된 성능은 80%의 온도효율과 70%의 배열회수율이 얻어졌으나, 실험적 결과로부터는 온도효율이 80%, 배열회수율이69%가 얻어졌다. 가장 큰 성능 차이는 배가스의 배출온도였는데, 이는 실제 시스템에서 열손실에 의한 축열기로의 배가스 유입온도 하락과 실제 운전에서의 공기/배가스 유량의 증가에 의해 기인된다고 판단된다.

  • PDF

연료전기용 컴팩트형 개질기의 고성능화를 위한 고온 공기 연소 기술의 적용에 관한 연구 (A Numerical Study on a High-Temperature Air Combustion Burner for a Compact Fuel-Cell Reformer)

  • 이경호;권오채
    • 한국수소및신에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.229-237
    • /
    • 2005
  • A new burner configuration for a compact fuel-cell reformer with a high-temperature air combustion concept was numerically studied. The burner was designed for a 40 $Nm^3/hr$ hydrogen-generated reformer using natural gas-steam reforming method. In order to satisfy the primary requirements for designing a reformer burner (uniform distribution of temperature along the fuel processor walls and minimum heat losses from the reformer), the features of the present burner configuration included 1) a self-regenerative burner for an exhaust-gas-recirculation to apply for the high-temperature air combustion concept, and 2) an annular-type shield for protecting direct contact of flame with the processor walls. For the injection velocities of the recirculated gas of 0.6-2.4 m/s, the recirculated gas temperature of 1000 K, and the recirculated oxygen mole fraction of 4%, the temperature distributions along the processor walls were found uniform within 100 K variation. Thus, the present burner configuration satisfied the requirement for reducing temperature gradients along the processor walls, and consequently demonstrated that the high-temperature air combustion concept could be applied to the practical fuel reformers for use of fuel cells. The uniformity of temperature distribution is enhanced as the amount of the recirculated gas increases.

열처리로용 소형 축열식 복사관 버너의 축열기 설계 기술평가 (Design and Performance Estimation of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner)

  • 조한창;조길원;이용국
    • 에너지공학
    • /
    • 제13권4호
    • /
    • pp.291-295
    • /
    • 2004
  • 열처리로에 적용되는 소형 축열식 복사관 버너시스템에 사용될 축열기를 설계, 제작하고 그 성능을 실제 축열식 복사관 버너시스템에서 평가하였다. 좁은 튜브간 간격을 갖는 U형 복사관에 축열기를 적용하기 위하여 상하단 단면적이 다른 축열기를 설계, 적용하였다. 구형축열체를 사용하는 2만 ㎉/hr급 축열기를 기존에 개발된 축열기 해석코드를 이용하여 설계, 제작하였으며, 축열기 전후단의 온도 및 압력을 실시간으로 측정하였다. 실험결과를 축열기 해석코드로부터 얻은 배가스의 배출온도와 공기의 예열온도를 비교하여 해석코드의 정확도를 검증하였다. 이론적으로 예상된 성능은 80%의 온도효율과 70%의 배열회수율이 얻어졌으나, 실험적 결과로부터는 온도효율이 80%, 배열회수율이 69%가 얻어졌다. 가장 큰 성능차이는 배가스의 배출온도였는데, 이는 실제 시스템에서 열손실에 의한 축열기로의 배가스 유입온도 하락과 실제 운전에서의 공기/배가스 유량의 증가에 의해 기인된다고 판단된다.

고속분사를 이용한 소형 축열식 복사관 버너시스템의 성능평가 (Performance Estimation of Small Regenerative Radiant Tube Burner System using High Velocity Discharge)

  • 조한창;조길원;이용국
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.242-247
    • /
    • 2004
  • An Experimental study was conducted on spray combustion using dual swirlers at different outlet angle; co-swirl and counter-swirl. To understand the characteristics of turbulent spray combustion of dual swirl flow (DSF), the axial helical annular vaned swirlers with various swirl ratios and combination of angle and direction were designed. and temperature measurements of a rapidly thermocouple insertion and measurements of soot volume fraction and microrstructure using thermophoretic sampling particle diagnostic (TSPD) as TEM were carried out. The NOx, $CO_2$, $O_2$, etc. was analyzed using emission gas analyzer. The results show that flame stability were maintained under very lean condition. for both co-swirl and counter-swirl case. And though Counter-swirl case kept the higher temperature region compared to co-swirl case, Counter-swirl combustion represented less NOx emission and soot formation than co-swirl case.

  • PDF