Design and Performance Estimation of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner  

Cho H. C. (포항산업과학연구원 에너지연구팀)
Cho K. W. (포항산업과학연구원 에너지연구팀)
Lee Y. K. (포항산업과학연구원 에너지연구팀)
Publication Information
Abstract
Heat regenerator attached in small-scale regenerative radiant tube burner was designed using the theoretical computation code and was confirmed the performance of waste heat recovery ratio. From the computation, when ceramic ball of 4-5kg was used, temperature efficiency and available waste heat recovery ratio were predicted 80% and 70%, respectively. Similar efficiencies were obtained from the experiments using LPG. However, since exhaust gas temperature entered into regenerator was below 850$^{\circ}C$ which was moth lower than that we expected. air preheating temperature was lowered below 800$^{\circ}C$.
Keywords
Radiant burner; Regenerator; Thermal efficiency;