Performance Estimation of Small Regenerative Radiant Tube Burner System using High Velocity Discharge

고속분사를 이용한 소형 축열식 복사관 버너시스템의 성능평가

  • 조한창 (포항산업과학연구원 에너지연구팀) ;
  • 조길원 (포항산업과학연구원 에너지연구팀) ;
  • 이용국 (포항산업과학연구원 에너지연구팀)
  • Published : 2004.06.04

Abstract

An Experimental study was conducted on spray combustion using dual swirlers at different outlet angle; co-swirl and counter-swirl. To understand the characteristics of turbulent spray combustion of dual swirl flow (DSF), the axial helical annular vaned swirlers with various swirl ratios and combination of angle and direction were designed. and temperature measurements of a rapidly thermocouple insertion and measurements of soot volume fraction and microrstructure using thermophoretic sampling particle diagnostic (TSPD) as TEM were carried out. The NOx, $CO_2$, $O_2$, etc. was analyzed using emission gas analyzer. The results show that flame stability were maintained under very lean condition. for both co-swirl and counter-swirl case. And though Counter-swirl case kept the higher temperature region compared to co-swirl case, Counter-swirl combustion represented less NOx emission and soot formation than co-swirl case.

Keywords