• Title/Summary/Keyword: reference-free

Search Result 578, Processing Time 0.026 seconds

Application of Passive Sampling in Marine Environment: 2. Modified Method for Shortening of Deployment Time in a Field (해양환경에서의 수동형채집기(Passive Sampler)의 활용: 2. 현장노출시간 단축을 위한 개선법)

  • JANG, YU LEE;LEE, HYO JIN;JEONG, HAE JIN;KIM, GI BEUM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.2
    • /
    • pp.249-265
    • /
    • 2019
  • A passive sampler is one of the promising methods to easily and more accurately predict the free dissolved and bioavailable concentration ($C_{free}$) in seawater or pore water in sediments. In Europe and the United States, the use of passive samplers has been highly encouraged for more accurate marine environmental risk assessment. However, long deployment time in the field causes problems such as biofouling of the samplers, so there are few studies using passive samplers in Korea. Therefore, we review the principle and basic characteristics of the passive sampler for persistent organic pollutants, and introduce various improvement cases for the field applications of the passive sampler.

A Study on Low-Melting Temperature Sn-In (wt%) Pb-Free Solders for Photovoltaic Ribbons (태양광 리본용 저융점 Sn-In (wt%) 무연 솔더 연구)

  • Dong-Hyeon Shin;Seung-Han Lee;Tae-Sik Cho;Il-Sub Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.2
    • /
    • pp.186-190
    • /
    • 2023
  • We studied the various characteristics of Sn-In (wt%) Pb-free solders for photovoltaic ribbon application. The solders near the eutectic composition of Sn48In52 (wt%) existed in InSn4 and In3Sn alloy phases, and in In crystal phase, but not in Sn crystal phase. In addition, the InSn4 phase (γ-alloy) existed separately from the In3Sn (β-alloy) and the In phase confirmed by an SEM-EDS-mapping. The melting temperature of the eutectic solder of Sn48In52 (wt%) was 119.2℃, and when the Sn content decreased in reference to the eutectic composition, it slightly increased to 121.4℃, but when the Sn content increased, it remained almost constant at 119.1℃. The peel strength of the ribbon plated with the Sn42In58 (wt%) solder was 38.7 N/mm2, and it tended to increase when the Sn content increased. The peel strength of the eutectic Sn48In52 (wt%) solder was 53.6 N/mm2, and that of the Sn51In49 (wt%) solder was 61.6 N/mm2 that was the highest.

A new semi-analytical approach for bending, buckling and free vibration analyses of power law functionally graded beams

  • Du, Mengjie;Liu, Jun;Ye, Wenbin;Yang, Fan;Lin, Gao
    • Structural Engineering and Mechanics
    • /
    • v.81 no.2
    • /
    • pp.179-194
    • /
    • 2022
  • The bending, buckling and free vibration responses of functionally graded material (FGM) beams are investigated semi-analytically by the scaled boundary finite element method (SBFEM) in this paper. In the concepts of the SBFEM, the dimension of computational domain can be reduced by one, therefore only the axial dimension of the beam is discretized using the higher order spectral element, which reduces the amount of calculation and greatly improves the calculation efficiency. The governing equation of FGM beams is derived in detail by the means of the principle of virtual work. Compared with the higher-order beam theory, fewer parameters and simpler control equations are used. And the governing equation is transformed into a first-order ordinary differential equation by introducing intermediate variables. Analytical solutions of the governing equation can be obtained by pade series expansion in the direction of thickness. Numerical example are compared with the numerical solutions provided by the previous researchers to verify the accuracy and applicability of the proposed method. The results show that the proposed formulations can quickly converge to the reference solutions by increasing the order of higher order spectral elements, and high accuracy can be achieved by using a small number of the elements. In addition, the influence of the structural sizes, material properties and boundary conditions on the mechanical behaviors of FG beams subjected to different load types is discussed.

Barrier-Free Subway Service System Scenario : Comparison Between Korea and China (한국과 중국의 비교를 통한 무장애 지하철 서비스시스템 시나리오 제안)

  • Jia-Xing Long;Sung-Pil Lee
    • Journal of Service Research and Studies
    • /
    • v.11 no.3
    • /
    • pp.55-74
    • /
    • 2021
  • In the global era, the tourism industry is a major profitable business, and the state and local governments are making various efforts to provide quality tourism experiences. The purpose of this study in a variety of tourism contents is to study barrier-free subway services in line with the global era, and to expand from the existing rapid, safe, and ordered transportation to the provision of high-quality comfort and all-round service experiences. This study compared and analyzed the subway service systems of Korea, China and both countries through the service design method, and presented a barrier-free subway service system to improve the user's satisfaction with the subway service system by improving the user's service experience. As a result, research results showed that 20 attractive quality attributes in 17 fields, such as convenience facilities, language issues, security equipment, and riding environment, play an important role in improving the quality and experience of subway services. In addition, through the construction of a Service Spatial Scenario, an optimized subway service system can be visualized to help understand this so that it can be used as a reference for creating a strategic application.

Quantification of Pancreas Surface Lobularity on CT: A Feasibility Study in the Normal Pancreas

  • Riccardo Sartoris;Alberto Calandra;Kyung Jin Lee;Tobias Gauss;Valerie Vilgrain;Maxime Ronot
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1300-1309
    • /
    • 2021
  • Objective: To assess the feasibility and reproducibility of pancreatic surface lobularity (PSL) quantification derived from abdominal computed tomography (CT) in a population of patients free from pancreatic disease. Materials and Methods: This retrospective study included 265 patients free from pancreatic disease who underwent contrast-enhanced abdominal CT between 2017 and 2019. A maximum of 11 individual PSL measurements were performed by two abdominal radiologists (head [5 measurements], body, and tail [3 measurements each]) using dedicated software. The influence of age, body mass index (BMI), and sex on PSL was assessed using the Pearson correlation and repeated measurements. Inter-reader agreement was assessed using the intraclass correlation coefficient (ICC) and Bland Altman (BA) plots. Results: CT images of 15 (6%) patients could not be analyzed. A total of 2750 measurements were performed in the remaining 250 patients (143 male [57%], mean age 45 years [range, 18-91]), and 2237 (81%) values were obtained in the head 951/1250 (76%), body 609/750 (81%), and tail 677/750 (90%). The mean ± standard deviation PSL was 6.53 ± 1.37. The mean PSL was significantly higher in male than in female (6.89 ± 1.30 vs. 6.06 ± 1.31, respectively, p < 0.001). PSL gradually increased with age (r = 0.32, p < 0.001) and BMI (r = 0.32, p < 0.001). Inter-reader agreement was excellent (ICC 0.82 [95% confidence interval 0.72-0.85], with a BA bias of 0.30 and 95% limits of agreement of -1.29 and 1.89). Conclusion: CT-based PSL quantification is feasible with a high success rate and inter-reader agreement in subjects free from pancreatic disease. Significant variations were observed according to sex, age, and BMI. This study provides a reference for future studies.

Egg Quality in Battery Cage and Free-Range Systems : with Reference to Comparison of Eggs Based on Price and Hens' Age (방사 사육과 배터리 사육 산란계에서 난질 : 난가와 산란계 주령에 따른 난질의 비교)

  • Kim, Dae-Woo;Kang, Seok-Min;Yang, Young-Rok;Kim, Ji-Min;Yoon, Hyung-Sook;Jeon, Jung-Hwan;Choi, Yang-Ho
    • Korean Journal of Organic Agriculture
    • /
    • v.24 no.1
    • /
    • pp.115-122
    • /
    • 2016
  • The main purpose of the current study was to compare quality of eggs 1) produced from hens housed in battery cages vs. free range, 2) from young vs. old hens, and 3) tagged with the lowest vs. the highest price in a local franchised mart. The ages of hens, at which their eggs were used for the analysis of quality, were 70 weeks old in the experiment 1, 22 and 47 weeks old in the experiment 2, and were unknown in the experiment 3. Eggs were analyzed for weight, albumen height, Haugh unit, shell color, shell strength, shell thickness, shell weight, yolk color, yolk weight, and egg white weight. In the experiment 1, significant differences were detected between two housing systems in shell color, shell weight, yolk color, and yolk weight (P<0.05), but not in egg weight, albumen height, Haugh unit, shell strength, shell thickness, and egg white weight (P>0.05). Although egg weight was slightly but not significantly higher in battery cages by 2.2 g than in free range, yolk weight was significantly higher in battery cage (P<0.05). On the contrary, shell color was greatly increased in free range system by 68.5% compared with battery cage. In the experiment 2, there were significant differences between young and old hens in egg weight, albumen height, Haugh unit, shell strength, shell weight, yolk color and yolk weight (P<0.05). Egg weight, shell weight, yolk color and yolk weight were increased in old hens than young hens while albumen height, Haugh unit, and shell strength were decreased. In the experiment 3, egg weight, albumen height, Haugh unit, shell weight, and egg white weight were significantly higher in the highest priced eggs than the lowest ones (P<0.05), whereas shell strength and yolk color were lower (P<0.05) but shell color, shell thickness and yolk weight were not different (P>0.05). So, egg freshness was clearly higher in the highest priced ones than in the lowest (P<0.05). Due to the limited information on raising and husbandry of laying hens whose eggs were tested for egg quality in the current study, the present results should be cautiously interpreted while contributing to the future study as a basis in this field.

Induction Chemotherapy Followed by Concurrent Chemoradiotherapy Versus Concurrent Chemoradiotherapy with or without Adjuvant Chemotherapy for Locoregionally Advanced Nasopharyngeal Carcinoma: Meta-analysis of 1,096 Patients from 11 Randomized Controlled Trials

  • Liang, Zhong-Guo;Zhu, Xiao-Dong;Tan, Ai-Hua;Jiang, Yan-Ming;Qu, Song;Su, Fang;Xu, Guo-Zeng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.515-521
    • /
    • 2013
  • Purpose: To evaluate the efficacy and toxicity of induction chemotherapy followed by concurrent chemoradiotherapy (the treatment group) versus concurrent chemoradiotherapy with or without adjuvant chemotherapy (the control group) for locoregionally advanced nasopharyngeal carcinoma. Methods: The search strategy included Pubmed, Embase, the Cochrane Library, China National Knowledge Internet Web, Chinese Biomedical Database and Wanfang Database. We also searched reference lists of articles and the volumes of abstracts of scientific meetings. All randomized controlled trials were included for a meta-analysis performed with RevMan 5.1.0. The Grading of Recommendations Assessment, Development, and Evaluation system (GRADE) was used to rate the level of evidence. Results: Eleven studies were included. Risk ratios of 0.99 (95%CI 0.72-1.36), 0.37 (95%CI 0.20-0.69), 1.08 (95%CI 0.84-1.38), 0.98 (95%CI 0.75-1.27) were observed for 3 years overall survival, 3 years progression-free survival, 2 years loco-regional failure-free survival and 2 years distant metastasis failure-free survival. There were no treatment-related deaths in either group in the 11 studies. Risk ratios of 1.90 (95%CI 1.24-2.92), 2.67 (95%CI 0.64-11.1), 1.04 (95%CI 0.79-1.37), 0.98 (95%CI 0.27-3.52) were found for grade 3-4 leukopenia, grade 3-4 thrombocytopenia, grade 3-4 mucous membrane, and grade 3-4 hepatic hematologic and gastrointestinal toxicity, the most significant toxicities for patients. Conclusion: Compared with the control group, induction chemotherapy followed by concurrent chemoradiotherapy was well tolerated but could not significantly improve prognosis in terms of overall survival, loco-regional failure-free survival or distant metastasis failure-free survival.

Dynamic-Response-Free SMPS Using a New High-Resolution DPWM Generator Based on Switched-Capacitor Delay Technique (Switched-Capacitor 지연 기법의 새로운 고해상도 DPWM 발생기를 이용한 Dynamic-Response-Free SMPS)

  • Lim, Ji-Hoon;Park, Young-Kyun;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • In this paper, we suggest the dynamic-response-free SMPS using a new high-resolution DPWM generator based on switched-capacitor delay technique. In the proposed system, duty ratio of DPWM is controlled by voltage slope of an internal capacitor using switched-capacitor delay technique. In the proposed circuit, it is possible to track output voltage by controlling current of the internal capacitor of the DPWM generator through comparison between the feedback voltage and the reference voltage. Therefore the proposed circuit is not restricted by the dynamic-response characteristic which is a problem in the existing SMPS using the closed-loop control method. In addition, it has great advantage that ringing phenomenon due to overshoot/undershoot does not appear on output voltage. The proposed circuit can operate at switching frequencies of 1MHz~10MHz using internal operating frequency of 100 MHz. The maximum current of the core circuit is 2.7 mA and the total current of the entire circuit including output buffer is 15 mA at the switching frequency of 10 MHz. The proposed circuit has DPWM duty ratio resolution of 0.125 %. It can accommodate load current up to 1 A. The maximum ripple of output voltage is 8 mV. To verify operation of the proposed circuit, we carried out simulation with Dongbu Hitek BCD $0.35{\mu}m$ technology parameter.

Elastic Wave Propagation in Monoclinic System Due to Transient Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2E
    • /
    • pp.53-58
    • /
    • 1998
  • In this paper, we study the response of several anisotropic systems to buried transient line loads. The problem is mathematically formulated based on the equations of motion in the constitutive relations. The load is in form of a normal stress acting with arbitrary axis on the plane of monoclinic symmetry. Plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in reference coordinate system, where the line load is coincident with symmetry axis of the orthotrioic material. Then the equation of motion is transformed with respect to general coordiante system with azimuthal angle by using transformation tensor. The load is first described as a body force in the equations of the motion for the infinite media and then it is mathematically characterized. Subsequently the results for semi-infinite spaces is also obtained by using superposition of the infinite medium solution together with a scattered solution from the free surface. Consequently explicit solutions for the displacements are obtained by using Cargniard-DeHoop contour. Numerical results which are drawn from concrete examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF

Modal analysis of perforated rectangular plates in contact with water

  • Jeong, Kyeong-Hoon;Ahn, Byung-Ki;Lee, Seong-Cheol
    • Structural Engineering and Mechanics
    • /
    • v.12 no.2
    • /
    • pp.189-200
    • /
    • 2001
  • This paper presents an experimental modal analysis of perforated rectangular plates in air or in contact with water. The penetration of holes in the plates had a triangular pattern with P/D (pitch to diameter) 2.125, 2.500, 3.000 and 3.750. The plate was clamped along the plate edges by a number of bolts and nuts. The natural frequencies of the perforated plates in air were obtained by the analytical method based on the relation between the reference kinetic and maximum potential energies and compared with the experimental results. Good agreement between the results was found for the natural frequencies of the perforated plates in air. Additionally, it was empirically found that the natural frequencies of the perforated plate in air increase with an increase of P/D, on the other hand, the natural frequencies of the perforated plate in contact with water decrease with an increase of P/D.