• Title/Summary/Keyword: reduction coefficient

Search Result 1,319, Processing Time 0.029 seconds

AERODYNAMIC EFFECT OF ROOF-FAIRING SYSTEM ON A HEAVY-DUTY TRUCK

  • KIM C. H.;YOUN C. B.
    • International Journal of Automotive Technology
    • /
    • v.6 no.3
    • /
    • pp.221-227
    • /
    • 2005
  • Aim of this study is to investigate an aerodynamic effect of a drag-reducing device on a heavy-duty truck. The vehicle experiences two different kinds of aerodynamic forces such as drag and uplifting force (or downward force) as it is traveling straight forward at constant speed. The drag force on a vehicle may cause an increase of the rate of fuel consumption and driving instability. The rolling resistance of the vehicle may be increased as result of the negative uplifting or downward force on the vehicle. A device named roof-fairing system has been applied to examine the reduction of aerodynamic drag force on a heavy-duty truck. As for a engineering design information, the drag-reducing system should be studied theoretically and experimentally for the best efficiency of the device. Four different types of roof-fairing model were considered in this study to investigate the aerodynamic effect on a model truck. The drag and downward force generated by vehicle has been obtained from numerical calculation conducted in this study. The forces produced on four fairing models considered in this study has been compared each other to evaluate the best fairing model in terms of aerodynamic performance. The result shows that the roof-fairing mounted truck has bigger negative uplifting or downward force than that of non-mounted truck in all speed ranges, and drag force on roof-fairing mounted truck has smaller than that of non-mounted truck. The drag coefficient $(C_D)$ of the roof-fairing mounted truck (Model-3) is reduced up to $41.3\%$ than that of non-mounted trucks (Model-1). A downward force generated by a roof-fairing mounted on a truck is linearly proportional to the rolling resistance force. Therefore, the negative lifting force on a heavy-duty truck is another important factor in aerodynamic design parameter and should be considered in the design of a drag-reducing device of a tractor-trailer. According to the numerical result obtained from present study, the drag force produced by the model-3 has the smallest of all in all speed ranges and has reasonable downward force. The smaller drag force on model-3 with 2/3h in height may results of smallest thickness of boundary layer generated on the topside of the container and the lowest intensity of turbulent kinetic energy occurs at the rear side of the container.

A Prediction and Analysis for Functional Change of Ecosystem in South Korea (생태계 용역가치를 이용한 대한민국 생태계의 기능적 변화 예측 및 분석)

  • Kim, Jin-Soo;Park, So-Young
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.2
    • /
    • pp.114-128
    • /
    • 2013
  • Rapid industrialization and economic growth have led to serious problems including reduced open space, environmental degradation, traffic congestion, and urban sprawl. These problems have been exacerbated by the absence of effective conservation and governance, and have resulted in various social conflicts. In response to these challenges, many scholar and government hope to achieve sustainable development through the establishment and management of environment-friendly planning. For this purpose, we would like to analyze functional change for ecosystem by future land-use/cover changes in South Korea. Toward this goal, we predicted land-use/cover changes from 2010 to 2060 using the future population of Statistics Korea and urban growth probability map created by logistic regression analysis and analyzed ecosystem service value using costanza's coefficient. In the case of scenario 1, ecosystem service value represented 6,783~7,092 million USD. In the case of scenario 2, ecosystem represented 6,775~7,089 million USD, 2.9~7.6 million USD decreased compared by scenario 1. This was the result of area reduction for farmland and wetland which have high environmental value relatively according to urban growth by development point of view. The results of this analysis indicate that environmentally sustainable systems and urban development must be applied to achieve sustainable development and environmental protection. Quantitative analysis of environmental values in accordance with environmental policy can help inform the decisions of policy makers and urban developers. Furthermore, forecasting urban growth based on future demand will provide more precise predictive analysis.

Design of a Low Power Digital Filter Using Variable Canonic Signed Digit Coefficients (가변 CSD 계수를 이용한 저전력 디지털 필터의 설계)

  • Kim, Yeong-U;Yu, Jae-Taek;Kim, Su-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.7
    • /
    • pp.455-463
    • /
    • 2001
  • In this Paper, an approximate processing method is proposed and tested. The proposed method uses variable CSD (VCSD) coefficients which approximate filter stopband attenuation by controlling the precision of the CSD coefficient sets. A decimation filter for Audio Codec '97 specifications has been designed having processor architecture that consists of program/data memory, arithmetic unit, energy/level decision, and sinc filter blocks, and fabricated with 0.6${\mu}{\textrm}{m}$ CMOS sea-of-gate technology. For the combined two halfband FIR filters in decimation filter, the number of addition operations were reduced to 63.5%, 35.7%, and 13.9%, compared to worst-case which is not an adaptive one. Experimental results show that the total power reduction rate of the filter is varying from 3.8 % to 9.0 % with respect to worst-case. The proposed approximate processing method using variable CSD coefficients is readily applicable to various kinds of filters and suitable, especially, for the speech and audio applications, like oversampling ADCs and DACs, filter banks, voice/audio codecs, etc.

  • PDF

Temperature Dependence of Matching Characteristics of MIM Capacitor (MIM 커패시터에서의 정합특성의 온도에 대한 의존성)

  • Jang, Jae-Hyung;Kwon, Hyuk-Min;Kwak, Ho-Young;Kwon, Sung-Kyu;Hwang, Seon-Man;Sung, Seung-Yong;Shin, Jong-Kwan;Lee, Hi-Deok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.61-66
    • /
    • 2013
  • In this paper, temperature dependence of matching characteristics of $Si_3N_4$ MIM capacitor was analyzed in depth. The matching characteristics becomes worse as the temperature increases. That is, the matching coefficient of $Si_3N_4$ MIM capacitor at $25^{\circ}C$, $75^{\circ}C$, and $125^{\circ}C$ was 0.5870, 0.6151, and $0.7861%{\mu}m$, respectively. This phenomena is believed to be due to the reduction of the carrier mobility and the increase of the charge concentration of the inner capacitor at greater temperature. Therefore, the analysis of the matching characteristics of $Si_3N_4$ MIM capacitors at high temperatures is essential for application to analog and SoC (System on Chip) circuit.

The Effect of Kimchi Intake on Free Radical Production and the Inhibition of Oxidation in Young Adults and the Elderly People (김치가 청장년 및 노인의 유리기 생성 및 산화억제에 미치는 영향)

  • 김종현;류재두;무산대학임상병리과
    • Korean Journal of Community Nutrition
    • /
    • v.7 no.2
    • /
    • pp.257-265
    • /
    • 2002
  • This study was performed to investigate the effect of kimchi intake on free radical and oxidative substance production in young adults and the elderly. Daily kimchi intake by people in their twenties (n = 93, 20 to 29 years old) and over sixty-five (n = 143, over 65 years old) in M city were surveyed and blood was drawn to analyze the free radicals in their plasma. The average amount of kimchi intake by the subjects was 115.8 $\pm$ 91.7 g. The amount of kimchi intake of those in their twenties (106.1 $\pm$ 80.6 g) was significantly lower than that of those over sixty-five (125.5 $\pm$ 102.9 g, p < 0.05). Concentrations of total free radicals and OH radicals were 27 and 33% greater respectively, in those over sixty-five than in those in their twenties, indicating that more free radicals were produced by the older group. The concentration of GSH was not signiacantly different in the two groups, but that of GSSG in the over sixty-five age group was 53% greater than in the twenties group, which resulted in a 35% reduction in GSH/GSSG in the elderly group. TBARS concentration in the over sixty-five group was 26% greater than that of the twenties group. In order to see the effect of kimchi intake on free radical production, subjects in same age group were divided into two sub groups-the mean over and the mean under groups-according to the average amount of kimchi intake, which was 115.8 g. The total free radicals, the OH radicals, the GSH, the GSSG, and the GSH/GSSG in the twenties group were not significantly different in the two kimchi intake groups. However, those in the over sixty-five group were significantly different. The concentration of total free radicals and OH radicals of the mean over group were 21 and 26% lower respectively, than those of the mean ova. group (p < 0.05). The GSH and GSH/GSSG of the mean ova. groups were higher by 8 and 12%, respectively. The correlation coefficient between the kimchi intake and the total free radicals was -0.1862 (p < 0.05) and that for GSH/GSSG was 0.1861 (p < 0.05). In conclusion, the production of free radicals and oxidative substances increased with age, and kimchi seemed to retard this phenomena.

Reliability of Load-Carrying Capacity of RC Deep Beams (철근콘크리트 깊은 보의 내하력에 대한신뢰도 평가)

  • Cheon Ju-Hyun;Kim Tae-Hoon;Lee Sang-Cheol;Shin Hyun-Mock
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.955-962
    • /
    • 2005
  • Still no accurate theory exists for predicting ultimate shear strength of deep reinforced concrete beams because of the structural and material non-linearity after cracking. Currently, the load capacity assesment is performed for the upper structure of the bridges and containing non-reliability in the applications and results. The purpose in this study is to evaluate analytically the complex shear behaviors and normal strength for the reinforced concrete deep beams and to offer the accuracy load capacity assesment method based on the reliability theories. This paper presents a method for the load capacity assesment of reinforcement concrete deep beams using nonlinear finite element analysis. A computer program named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. Material non-linearity is taken Into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. From the results, determine the reliability index for the failure base on the Euro Code. Then, calculate additional reduction coefficient to satisfy the goals from the reliability analysis. The proposed numerical method for the load capacity assesment of reinforced concrete deep beams is verified by comparison with the others methods.

Microwave Dielectric Properties and Far Infrared Spectrum of $(Pb_{1-x}Ca_x)(Fe_{0.5}Ta_{0.5})O_3$ Ceramics ($(Pb_{1-x}Ca_x)(Fe_{0.5}Ta_{0.5})O_3$ 세라믹스의 마이크로파 유전특성 및 Far Infrared Spectrum)

  • 박흥수;윤기현;김응수
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.3
    • /
    • pp.256-262
    • /
    • 2000
  • The dielectric properties of complex perovskite ($Pb_{1-x}Ca_{x}$)($Fe_{0.5}Ta_{0.5}$)$O_{3}$ with >($0.5{\le}x{\ge}0.65$ were investigated at microwave frequencies. Dilectric constant decreased with increasing Ca content, and was directly proportional to the cube of average ionic ra야 of A-site. For the specimen of x=0.6 sintered at $1250^{\circ}C$ for 3 h in air, dielectric constant (k) of 63, QF of 11000 GHz, and the temperature coefficient of resonant frequency(TCF) of -14ppm/$^{\circ}C$ were obtained. As Ca content increased, TCF of the specimen negatively increased due to the reduction of the tolerance factor(t). Changes in intrinsic loss with varying Ca content was investigated by the infrared reflectivity spectra ranging 50 to 4000 $cm^{-1}$, which were calculated by the Kramers-Kronig analysis and classical oscillator model. The relative tendency of microwave dielectric properties of the ($Pb_{1-x}Ca_{x}$)($Fe_{0.5}Ta_{0.5}$)$O_{3}$ specimens calculated from the reflectivity data were in good agreement with the results by the post resonant method.

  • PDF

An effective transform hardware design for real-time HEVC encoder (HEVC 부호기의 실시간처리를 위한 효율적인 변환기 하드웨어 설계)

  • Jo, Heung-seon;Kumi, Fred Adu;Ryoo, Kwang-ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.416-419
    • /
    • 2015
  • In this paper, we propose an effective design of transform hardware for real-time HEVC(High Efficiency Video Coding) encoder. HEVC encoder determines the transform mode($4{\times}4$, $8{\times}8$, $16{\times}16$, $32{\times}32$) by comparing RDCost. RDCost require a significant amount of computation and time because it is determined by bit-rate and distortion which is computated via transform, quantization, dequantization, and inverse transform. This paper therefore proposes a new method for transform mode determination using sum of transform coefficient. Also, proposed hardware architecture is implemented with multiplexer, recursive adder/subtracter, and shifter only to derive reduction of the computation. Proposed method for transform mode determination results in an increase of 0.096 in BD-PSNR, 0.057 in BD-Bitrate, and decrease of 9.3% in encoding time by comparing HM 10.0. The hardware which is proposed is implemented by 256K logic gates in TSMC 130nm process. Its maximum operation frequency is 200MHz. At 140MHz, the proposed hardware can support 4K Ultra HD video encoding at 60fps in real time.

  • PDF

The recombination velocity at III-V compound heterojunctions with applications to Al/$_x$/Ga/$_1-x$/As-GaAs/$_1-y$/Sb/$_y$/ solar cells

  • 김정순
    • 전기의세계
    • /
    • v.28 no.4
    • /
    • pp.53-63
    • /
    • 1979
  • Interface recombination velocity in $Al_{x}$G $a_{1-x}$ As-GaAs and $Al_{0.85}$, G $a_{0.15}$ As-GaA $s_{1-y}$S $b_{y}$ heterojunction systems is studied as a function of lattice mismatch. The results are applied to the design of highly efficient III-V heterojunction solar cells. A horizontal liquid-phase epitaxial growth system was used to prepare p-p-p and p-p-n $Al_{x}$G $a_{1-x}$ As-GaA $s_{1-y}$S $b_{y}$-A $l_{x}$G $a_{1-x}$ As double heterojunction test samples with specified values of x and y. Samples were grown at each composition, with different GaAs and GaAs Sb layer thicknesses. A method was developed to obtain the lattice mismatch and lattice constants in mixed single crystals grown on (100) and (111)B oriented GaAs substrates. In the AlGaAs system, elastic lattice deformation with effective Poisson ratios .mu.$_{eff}$ (100=0.312 and .mu.$_{eff}$ (111B) =0.190 was observed. The lattice constant $a_{0}$ (A $l_{x}$G $a_{1-x}$ As)=5.6532+0.0084x.angs. was obtained at 300K which is in good Agreement with Vegard's law. In the GaAsSb system, although elastic lattice deformation was observed in (111) B-oriented crystals, misfit dislocations reduced the Poisson ratio to zero in (100)-oriented samples. When $a_{0}$ (GaSb)=6.0959 .angs. was assumed at 300K, both (100) and (111)B oriented GaAsSb layers deviated only slightly from Vegard's law. Both (100) and (111)B zero-mismatch $Al_{0.85}$ G $a_{0.15}$As-GaA $s_{1-y}$S $b_{y}$ layers were grown from melts with a weight ratio of $W_{sb}$ / $W_{Ga}$ =0.13 and a growth temperature of 840 to 820 .deg.C. The corresponding Sb compositions were y=0.015 and 0.024 on (100) and (111)B orientations, respectively. This occurs because of a fortuitous in the Sb distribution coefficient with orientation. Interface recombination velocity was estimated from the dependence of the effective minority carrier lifetime on double-heterojunction spacing, using either optical phase-shift or electroluminescence timedecay techniques. The recombination velocity at a (100) interface was reduced from (2 to 3)*10$^{4}$ for y=0 to (6 to 7)*10$^{3}$ cm/sec for lattice-matched $Al_{0.85}$G $a_{0.15}$As-GaA $s_{0.985}$S $b_{0.015}$ Although this reduction is slightly less than that expected from the exponential relationship between interface recombination velocity and lattice mismatch as found in the AlGaAs-GaAs system, solar cells constructed from such a combination of materials should have an excellent spectral response to photons with energies over the full range from 1.4 to 2.6 eV. Similar measurements on a (111) B oriented lattice-matched heterojunction produced some-what larger interface recombination velocities.ities.ities.s.

  • PDF

Impacts of Implementing Case Payment System to Medical Aid Hemodialysis Patients on Dialysis Frequencies and Expenditure (정액수가제 도입이 의료급여 혈액투석환자의 투석횟수 및 진료비에 미치는 영향)

  • Lee, Sun-Hee;Kim, Han-Joong;Shin, Seung-Ho;Cho, Woo-Hyun;Kang, Hye-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.3
    • /
    • pp.260-266
    • /
    • 2004
  • Objectives : To assess the impacts of implementing case payment system (CPS) to Medical Aid (MA) hemodialysis patients on the frequencies and expenditure of dialysis. Methods : Fifty-eight clinics and 35 tertiary care hospitals were identified as having a minimum of 10 hemodialysis patients for each of the MA and Medical Insurance (MI) programs, who received hemodialysis from the same dialysis facilities for both periods of July 2001 and July 2002. From these facilities, a total of 2,167 MA and 2,928 MI patients were identified as the study subjects. Using electronic claims data, the changes in the total number of monthly treatments and charges for outpatient hemodialysis treatments for each patient after the introduction of the CPS were compared between the MA and MI patients. Multiple regression analyses were performed to examine the independent impact of the CPS on the utilization and expenditure of dialysis treatments among the MA patients. Results : There was a significant decrease in the total charges for the hemodialysis treatments of the MA patients, 3.4% (p<0.05), whereas a significant increase was observed for the MI patients, 2.5% (p<0.05). For both the MA and MI patients, the frequency of the monthly hemodialysis treatments were significantly increased, 5.5 (from 12.1 to 12.7) and 7.8% (from 11.6 to 12.5), for the MA and MI patients, respectively. However, a multivariate regression analysis showed no significant difference in the changes in the total number of monthly hemodialysis treatments between the MA and MI patients after implementation of the CPS. Another regression model, regressing on the changes in the monthly claims of dialysis treatments, showed a significant negative coefficient for the MA ((=-70725, p<0.05). Conclusion : The significant decrease in the total charges for hemodialysis treatments among MA as compared to MI patients suggests that there was a cost reduction in the MA program following the introduction of the CPS.