• Title/Summary/Keyword: reduce CO2

Search Result 1,950, Processing Time 0.044 seconds

Estimation of Atmospheric Pollutant Emissions from Vessels in Major Harbor Cities in Korea and related Social Cost (국내 주요 항구도시의 선박 배기가스 배출량 산정 및 사회적 비용 추정)

  • Choi, Jung-kil;Kim, Myung-won;Lee, Hyo-jin;Kang, Tea-soon;Lee, Kang-wung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.905-917
    • /
    • 2021
  • Atmospheric pollutant emissions, mainly exhaust gas emissions from vessels, and the resultant social costs of pollution in the Korean harbor cities of Incheon, Mokpo, Gwangyang, Busan and Ulsan, are examined in this study, and the need for an emissions reduction plan is highlighted. Busan had several vessels entering its port, while Mokpo had few vessels, yet the vessels emission contribution was high in both the cities. Ulsan had world-class heavy-chemical industries, Gwangyang had steel mills and Incheon had a manufacturing industry and more vessels entering its port than Mokpo, yet the emission contribution was low in these cities. By calculating exhaust gas emissions from the vessels, it was found that CO2 was the highest, followed by NOx and SOx. By vessel type, Busan, Ulsan, and Incheon had more oil tank vessels, Gwangyang had more cargo vessels, and Mokpo had more ferries. As a result of social cost, Busan paid the highest, while the highest emission was PM. The use of low-sulfur oil can directly reduce PM and, SOx emissions and indirectly reduce NOx emissions. However, in order to reduce high CO2 emissions, only low-sulfur oil will not help. Therefore, the study suggested the need for reduction plan that use of fossil fuels, by using alternative maritime power (AMP).

A Comparative Study on Domestic and International Evaluation Criteria of Commissioning for Sustainable Building Certification (국내외 녹색건축인증에서의 커미셔닝 평가기준에 대한 비교 연구)

  • Jeong, Dahun;Jung, Chanwoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2017
  • Ministry of Land, Infrastructure and Transport established Heating and cooling energy conservation plan of apartment for 2017, reducing 90% compared to energy consumption of 1990. Also, at 2015 United Nations Climate Change Conference, the Ministry announced to reduce 37% of estimated $CO^2$ emission(850 million ton) at 2030. To satisfy this, it is urgent to reduce $CO^2$ emission due to the building, which takes majority amount of total $CO^2$ emission, and public interest for the commissioning of intensified building performance is uprising. However, the building commissioning at construction is not enacted, and not activated due to the lackness of promotion and will of general contractor. Furthermore, commissioning is not mandatory for obtaining G-SEED certification. Therefore, this paper describes effectiveness of commissioning with comparison of commissioning evaluation criteria of G-SEED with LEED and BREEAM, to propose making commissioning as mandatory process and drive changes in perception among stakeholders for activation of domestic building commissioning.

International Environmental Efficiency with CO2 Using Meta Stochastic Frontier Analysis (메타확률 프런티어를 사용한 CO2의 국제환경효율)

  • Li, Ziyao;Kang, Sangmok
    • Environmental and Resource Economics Review
    • /
    • v.30 no.3
    • /
    • pp.471-501
    • /
    • 2021
  • We measure Environmental Efficiency (EE) based on CO2 in four income groups from 1998 to 2018, using the Meta Stochastic Frontier Analysis method by Input Distance Function. Our results showed that economic growth and energy consumption would increase carbon dioxide emissions, and increasing labor and capital input will reduce it. Moreover, we compared Group Environmental Efficiency (GEE), Meta Environmental Efficiency (MEE), and Environmental Gap Ratio (EGR). The results showed that GEEs were be overestimated. Furthermore, the MEE showed a downward trend during this period. The lower-middle-income group had the highest EGR performance. High-income and upper-middle-income groups showed less efficiency in MEE and EGR. To improve environmental efficiency, we must reduce fossil fuels and find more scientific and technological ways to solve existing environmental problems as soon as possible.

Noise-robust Phase Gradient Retrieval Formulation for Phase-shifting Interferometry

  • Park, Dae-Seo;O, Beom-Hoan;Park, Se-Geun;Lee, El-Hang;Park, Jae-Hyun;Lee, Seung-Gol
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.131-136
    • /
    • 2010
  • Modification of the phase gradient formulation is proposed in order to make phase retrieval less susceptible to noise. The modified formulation is derived from separation of the phase terms and the intensity modulation terms of interferograms, and subsequent differentiation to reduce the noise-induced error of the phase gradient vector. Its performance is evaluated and compared to that of the conventional formulation, and noise-robust nature is confirmed.

Design and Construction Study of an Injection Facility for CO2 Offshore Storage (CO2 해상 지중저장을 위한 주입설비 설계 및 구축 연구)

  • Moon, Hung-Man;Kim, Hyo-Joon;Shin, Se-Jin;Lee, Yong-Il;Kwon, Si-Hyun;Kwon, Yi-Kyun
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.207-215
    • /
    • 2018
  • Almost all countries of the world have recently made great efforts to reduce green-house gases to alleviate the global warming threatening human survival, because a huge amount of carbon dioxide as one of the main green-house gases has been emitted from the combustion processes of fossil fuels such as coal and oil. $CO_2$ capture and storage (CCS) technology is a representative method to diminish the green-house gases, and actively investigated by many countries. This study focuses on the design and construction of a high pressure $CO_2$ injection facility to store it to underground, which is the first $CO_2$ injection in Korea following the steps of the $CO_2$ capture from large $CO_2$ emission sources and transportation to the sea. Injection tests of $CO_2$ on the platform on the sea were carried out in Yeongil Bay of Pohang city in the early 2017. Thus, we were able to perceive the necessary operating conditions of the injection facility, injection characteristic, and knowhow of the injection facility. The results obtained from the injection test shall be utilized for facility upgrades and scale-ups.

Membrane-based Direct Air Capture Technologies (분리막을 이용한 공기 중 이산화탄소 제거 기술)

  • Yoo, Seung Yeon;Park, Ho Bum
    • Membrane Journal
    • /
    • v.30 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • As the demand for fossil fuels continues to increase worldwide, carbon dioxide (CO2) concentration in the air has increased over the centuries. The way to reduce CO2 emissions to the atmosphere, carbon capture and sequestration (CCS) technology have been developed that can be applied to power plants and factories, which are primary emission sources. According to the climate change mitigation policy, direct air capture (DAC) in air, referred to as "negative emission" technology, has a low CO2 concentration of 0.04%, so it is focused on adsorbent research, unlike conventional CCS technology. In the DAC field, chemical adsorbents using CO2 absorption, solid absorbents, amine-functionalized materials, and ion exchange resins have been studied. Since the absorbent-based technology requires a high-temperature heat treatment process according to the absorbent regeneration, the membrane-based CO2 capture system has a great potential Membrane-based system is also expected for indoor CO2 ventilation systems and immediate CO2 supply to smart farming systems. CO2 capture efficiency should be improved through efficient process design and material performance improvement.

A Study on $CO_2$ Emission Estimation linked Port Action (항만 연계활동에 기초한 이산화탄소 배출량 추정)

  • Kim, Hwan-Seong;Jo, Min-Ji
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.173-174
    • /
    • 2010
  • As the quantity of goods transported, port industry and inland transport industry have developing to transport 630million ton goods annually. And the inland transport industry consists of ground transport for almost 80% of total transported goods. But, ground transport causes some serious problems especially the emission of greenhouse gases from trucks. According to issue "global warming", many regulations and agreements with countries in the world are becoming necessary and it is being fulfilled now. It is sure that Korea will have duty to reduce CO2 emission from 2013. Thus inland transport must cut off CO2 emission level. Therefore this paper will address that the calculation of CO2 emission under route of transportation container from six major container ports in Korea. And then, it will predict CO2 emission of inland transport industry according to increasing container traffic rate at ports.

  • PDF

Flexural Capacity and CO2 Reduction Evaluation for Composite Beam with Weight Reducing Steel Wire-Integrated Void Deck Plate slab (자중저감 철선일체형 중공 데크플레이트 슬래브를 사용한 합성보의 휨내력 및 CO2 감소량 평가)

  • Kim, Sang-Seop;Park, Dong-Soo;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.313-323
    • /
    • 2012
  • The purpose of this study is to evaluate $CO_2$ reduction and the flexural performance of steel wire-integrated void deck plate slabs that were inserted in omega-shaped steel plates to reduce concrete and welded H-section beams. The void deck plate slab can secure the structure, not only reducing the weight of the building but it is also eco-friendly. Therefore, this study evaluated the flexural performance of the composite beam by conducting a monotonic loading test with the use of actuators. It quantitatively evaluated the $CO_2$ emission based on earlier studies. The main test parameters are the concrete thickness of upper slabs, and the interrupted width of the omega-shaped steel plate. The result of the test showed that the welded H-section beam applied steel wire-integrated void deck plate slabs that were inserted into the omega-shaped steel plate declined in flexural performance on the composite beam after reducing concrete volume. Likewise, it is effective in reducing $CO_2$.

Study on an Evaluation of Remote Control Torch Performance to reduce CO2 Welding Defects (CO2 용접결함 감소를 위한 원격 제어 토치 성능 평가 연구)

  • Kim, Jeong-Hyeok;Oh, Seck-Hyeog;Lee, Hae-Gil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6282-6288
    • /
    • 2014
  • $CO_2$ welding is used widely in the field. On the other hand, welding defects occur when welders cannot adjust the current and voltage needed for welding and have to stop working to adjust the current and voltage, causing sudden cooling down of the welding structure inside a vehicle or tank where the control panel is invisible or when work site is far. This study used three types of existing $CO_2$ welders. This also applied SS400 rolled steel for welding structural purposes for remote control torch welding, perform a welding test through v-groove butt welding with a remote control torch and existing $CO_2$ welding torch, conducted visual inspection on the appearance of a welded top bead. In addition, the appearance quality of the welding part was monitored mainly through penetrant testing and a bending test to evaluate the welding defect reduction and the effect on the performance and compatibility by replacing the existing welder.

Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin (지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;Nam, Goong-Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF