• 제목/요약/키워드: readout stability

검색결과 11건 처리시간 0.017초

Pre-and Post-Curing of Readout Layer of Super Resolution Disc

  • Kim, Sun-Hee;Kwak, Keum-Cheol;Lee, Chang-Ho;Song, Ki-Chang
    • 정보저장시스템학회논문집
    • /
    • 제3권3호
    • /
    • pp.113-117
    • /
    • 2007
  • 재생층이 상변화물질로 이루어진 초해상 광디스크에 있어서, 기록 전과 후에 thermal curing 을 실시하여 신호품질과 재생안정성이 크게 향상되었다. Pre-curing으로 수천 회 이하에서 나타나는 short-term stability가 향상되었고, post-curing 한 후 mid-term stability 가 향상되었다. 그리고, pre- and post-curing 후 noise level 은 전반적으로 $1{\sim}2dB$가 낮아졌고, CNR은 $2{\sim}3dB$, jitter 는 $2{\sim}3%$ 가 향상되었다.

  • PDF

Stability Enhancement of Super-RENS Readout Signal

  • Kim, Joo-Ho;Lee, Yong-Woon;Hwang, Wook-Yeon;Shima, Takayuki;Chung, Chong-Sam
    • 정보저장시스템학회논문집
    • /
    • 제3권3호
    • /
    • pp.123-125
    • /
    • 2007
  • We report the readout stability improvement results of super-resolution near field structure (Super-RENS) writeonce read-many (WORM) disk at a blue laser optical system. (Laser wavelength 405nm, numerical aperture 0.85) By using diffusion barrier structure (GeSbTe sandwiched by GeN) and high transition temperature recording material ($BaTiO_3$), material diffusion of phase change layer and recording mark degradation were greatly improved during high power (Pr=2.0mW) readout process up to $1{\times}10^5$ times.

  • PDF

원자외선 분광기의 2차원 위치검출을 위한 고 분해능 지연선 검출회로 (HIGH RESOLUTION DELAY LINE READOUT ELECTRONOCS FOR THE TIME 2-D POSITION SENSITIVE DETECTOR)

  • 이진근;신종호;민경욱;남욱원;공경남
    • Journal of Astronomy and Space Sciences
    • /
    • 제19권1호
    • /
    • pp.57-66
    • /
    • 2002
  • MCP(microchannel plate)와 지연산 양극판(delay line anode), 그리고 지연선 검출회로로 구성되는, 원자외선 분광기 에 사용될 2차원 지연선(delay line) 방식 의 위 치 검출기 (position sensitive detector)를 설계하고 그 중 지연선 검출회로를 제작하여 동작 및 분해능에 대한 시험을 수행하였다. 이 시험에서는 검출회로의 고유한 분해능을 확인하기 위하여 MCP와 양극판은 각파 특성이 잘 알려진 스티뮬레이션(stimulator)와 양극판 시뮬레이터(anode simulator)로 대체되었다. 제작된 검출회로는 안정적으로 동작하였으며 분광 및 영상 축 방향으로 각각 약 570ps와 약 100ps의 시간 분해능을 가지는 것을 확인하였다

우즈베키스탄 Maidanak 천문대 Fairchild 486 CCD의 기본적인 특성 (CHARACTERISTICS OF THE FAIRCHILD 486 CCD AT MAIDANAK ASTRONOMICAL OBSERVATORY IN UZBEKISTAN)

  • 임범두;성환경
    • 천문학논총
    • /
    • 제23권1호
    • /
    • pp.1-12
    • /
    • 2008
  • Understanding of the basic characteristics of an astronomical instrument is a prerequisite to obtaining reliable data from the instrument. We have analyzed more than 1,000 calibration images from the Fairchild 486 CCD (hereafter the Maidanak 4k CCD system) attached to the AZT-22 1.5m telescope at Maidanak Astronomical Observatory in Uzbekistan. The Maidanak 4k CCD system supports three readout modes through 1, 2, or 4 amplifiers. In most cases observers use 4-amplifier readout mode to save time. We have tested the stability and seasonal variation of zero levels and confirm that two quadrants of the images (Amp 1 & 2) show no appreciable seasonal variation. but the other two quadrants (Amp 3 & Amp 4) show an evident seasonal variation in the bias level. The Cryo Tiger, the cooling system used at the Maidanak 4k CCD system, maintains the CCD temperature at -108'E, and effectively suppresses the dark electrons. The mean value versus the variance plot of the flat images does not show the expected relation for an ideal Poisson noise distribution and this is attributed to the large variation in quantum efficiency between different pixels. In addition, we confirm that there is no appreciable difference in gain between readout amplifiers, but there is a large variation in quantum efficiency across CCD chip especially in U. Due to the finite length of shutter opening and closing time, the effective exposure time varies across the science images. We introduce two parameters to quantify the effect of this uneven illumination and present a method to remove these effects. We also present a method to remove the interference patterns appearing in the images obtained with longer wavelength filters and investigate the spatial variation of the point spread function.

적외선 탐색기 신호처리를 위한 극저온 밴드갭 회로 동작 조건 제안 및 제작된 칩의 성능 분석 (Operating Conditions Proposal of Bandgap Circuit at Cryogenic Temperature for Signal Processing of Infrared Detector and a Performance Analysis of a Manufactured Chip)

  • 김연규;강상구;이희철
    • 대한전자공학회논문지SD
    • /
    • 제41권12호
    • /
    • pp.59-65
    • /
    • 2004
  • 적외선 소자로부터 생성되는 신호의 잡음 특성의 향상, 즉 좋은 영상을 얻기 위해서 적외선 영상신호 취득회로(ROIC)에서는 안정적인 기준 전압원이 필요하다. 본 논문은 극저온인 77K에서 동작하는 적외선 영상신호 취득회로(readout integrated circuit)를 위한 밴드갭 회로를 처음으로 제작한 후 측정, 평가하여 그 실용 가능성을 입증하고 있다. 밴드갭 회로는 대표적인 전압 기준회로로서 기존에 발표된 대부분의 밴드갭 회로는 실온에서 동작하는 것이며, 액체질소 온도 77K에서는 그 특성이 적합하지 않다. 본 논문에서는 극저온에서 동작하는 밴드갭 회로 설계를 위하여, 그에 맞는 회로를 선택하여 온도변화에 따른 사용되는 소자들의 파라미터에 대한 이론정립을 통한 그것의 특성을 살펴보고, 이러한 특성들을 고려하여 저온동작에 적합도록 하였다. 이 회로는 Hynix 0.6um standard CMOS 공정을 통해서 제작되었으며, 측정된 출력전압($V_{out}$)은 60K에서 110K까지 1.0396$\pm$0.0015V로서 기존의 실온에 동작하던 밴드갭 회로보다 더 높은 안정도를 보여주었다.

A Resistance Deviation-To-Time Interval Converter Based On Dual-Slope Integration

  • Shang, Zhi-Heng;Chung, Won-Sup;Son, Sang-Hee
    • 전기전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.479-485
    • /
    • 2015
  • A resistance deviation-to-time interval converter based on dual-slope integration using second generation current conveyors (CCIIs) is designed for connecting resistive bridge sensors with a digital system. It consists of a differential integrator using CCIIs, a voltage comparator, and a digital control logic for controlling four analog switches. Experimental results exhibit that a conversion sensitivity amounts to $15.56{\mu}s/{\Omega}$ over the resistance deviation range of $0-200{\Omega}$ and its linearity error is less than ${\pm}0.02%$. Its temperature stability is less than $220ppm/^{\circ}C$ in the temperature range of $-25-85^{\circ}C$. Power dissipation of the converter is 60.2 mW.

CTIA 바이어스 상쇄회로를 갖는 초점면 배열에서 마이크로 볼로미터의 온도변화 해석 (Analyses of temperature change of a u-bolometer in Focal Plane Array with CTIA bias cancellation circuit)

  • 박승만
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2311-2317
    • /
    • 2011
  • In this paper, we study the temperature change of a ${\mu}$-bolometer focal plane array with a capacitive transimpedance amplifier bias cancellation circuit. Thermal analysis is essential to understand the performance of a ${\mu}$-bolometer focal plane array, and to improve the temperature stability of a focal plane array characteristics. In this study, the thermal analyses of a ${\mu}$-bolometer and its two reference detectors are carried out as a function of time. The analyses are done with the $30{\mu}m$ pitch $320{\times}240$ focal plane array operating of 60 Hz frame rate and having a columnwise readout. From the results, the temperature increase of a ${\mu}$-bolometer in FPA by an incident IR is estimated as $0.689^{\circ}C$, while the temperature increase by a pulsed bias as $7.1^{\circ}C$, which is about 10 times larger than by IR. The temperature increase of a reference detector by a train of bias pulses may be increased much higher than that of an active ${\mu}$-bolometer. The suppression of temperature increase in a reference bolometer can be done by increasing the thermal conductivity of the reference bolometer, in which the selection of thermal conductivity also determines the range of CTIA output voltage.

아날로그 메모리를 이용한 DC-DC컨버터 제어기 설계 (Design of DC-DC converter controller implemented with analog memory)

  • 채용웅;도왕록
    • 한국전자통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.357-364
    • /
    • 2015
  • 본 연구에서는 아날로그 메모리를 이용한 DC-DC 컨버터 제어기를 설계하였다. 이 방식은 기존의 폐루프 방식의 컨버터 제어기가 안고 있는 안정도 문제를 근본적으로 해결하는데 기여하게 될 것이다. 본 연구에서 아날로그 메모리는 컨버터의 출력과 이에 대응되는 최적의 시비율 판단을 위한 연상메모리를 구현하는데 이용된다. 메모리의 읽기 동작은 연상메모리의 최적 함수 선택을 위하여 절대값 회로와 승자전취 메커니즘 회로가 사용되며, 병렬의 고속 쓰기와 읽기 동작뿐만 아니라 고집적을 가능하게 하는 시스템 구성이 제안된다.

의료용 선형가속기의 기계적 점검을 위한 새로운 정도관리 프로토콜의 개발 (Development of New Prototype of Mechanical Quality Assurance for Clinical Linear Accelerator)

  • 윤형근;신교철;김기환;오영기;김진기;정동혁;김정기;조문준;박인규
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.109-113
    • /
    • 2002
  • 본 연구에서는 의료용선형가속기의 기기점검을 위한 일목요연하고 장기간의 통계처리가 가능한 새로운 정도관리 양식을 개발하였다. 개발된 양식을 2001년 8월부터 12월까지 국내의 6개의 기관에 적용하여 그 양식의 효율성을 평가하였다. 기존의 점검 양식은 단순히 선형가속기에 숫자로 표시되는 값들(digital data)과 측정장치를 이용하여 관찰된 값들(mechanical data)의 비교에 목적을 두고 있고, 각 항목들이 서술적으로 나열되어 있어 공간적으로 문제점을 파악하기 어렵다. 더욱이 기기의 장기간에 걸친 오차의 변화를 일목요연하게 알 수가 없다. 그러나 새로 개발된 점검 양식을 사용한다면, 디지털 데이터와 기계적 데이터의 비교는 물론 기기의 오차를 공간적으로 파악할 수 있게 될 것이다. 또한 기기의 장기간에 걸친 오차의 범위를 확인하게 되어 기기의 장기적 안정성을 알 수 있게 될 것이다. 뿐만 아니라 현실에 맞는 항목을 선택함으로써 기계적 정도관리(mechanical QA)를 수행하는 시간을 단축함과 동시에, 각 기관이 보유하고 있는 선형가속기의 장기간에 걸친 정도관리를 통해 얻은 데이터를 이용하여 치료장비의 오차에 대한 통계적, 물리적 데이터를 정도관리 직후 분석할 수 있게 되어 방사선 치료에 있어서 매우 중요한 요소인 방사선 치료장비의 기기적 정확성을 높일 수 있게 될 것이다.

  • PDF

Fundamental Metrology by Counting Single Flux and Single Charge Quanta with Superconducting Circuits

  • Niemeyer, J.
    • Progress in Superconductivity
    • /
    • 제4권1호
    • /
    • pp.1-9
    • /
    • 2002
  • Transferring single flux quanta across a Josephson junction at an exactly determined rate has made highly precise voltage measurements possible. Making use of self-shunted Nb-based SINIS junctions, programmable fast-switching DC voltage standards with output voltages of up to 10 V were produced. This development is now extended from fundamental DC measurements to the precise determination of AC voltages with arbitrary waveforms. Integrated RSFQ circuits will help to replace expensive semiconductor devices for frequency control and signal coding. Easy-to-handle AC and inexpensive quantum voltmeters of fundamental accuracy would be of interest to industry. In analogy to the development in the flux regime, metallic nanocircuits comprising small-area tunnel junctions and providing the coherent transport of single electrons might play an important role in quantum current metrology. By precise counting of single charges these circuits allow prototypes of quantum standards for electric current and capacitance to be realised. Replacing single electron devices by single Cooper pair circuits, the charge transfer rates and thus the quantum currents could be significantly increased. Recently, the principles of the gate-controlled transfer of individual Cooper pairs in superconducting A1 devices in different electromagnetic environments were demonstrated. The characteristics of these quantum coherent circuits can be improved by replacing the small aluminum tunnel Junctions by niobium junctions. Due to the higher value of the superconducting energy gap ($\Delta_{Nb}$$7\Delta_{Al}$), the characteristic energy and the frequency scales for Nb devices are substantially extended as compared to A1 devices. Although the fabrication of small Nb junctions presents a real challenge, the Nb-based metrological devices will be faster and more accurate in operation. Moreover, the Nb-based Cooper pair electrometer could be coupled to an Nb single Cooper pair qubit which can be beneficial for both, the stability of the qubit and its readout with a large signal-to-noise ratio..

  • PDF