• 제목/요약/키워드: ray following

검색결과 630건 처리시간 0.025초

방사선이 조사된 오갈피 나무의 추출물이 생쥐의 복강암 및 면역세포에 미치는 영향 (Effects of Extracts from Acanthopanax sessiliflorus SEEM Following Gamma-ray Irradiation on Solid Tumor and Immune Cells in Mice)

  • 김형우;조수인;김계엽;전병관;조영림;정현우
    • 동의생리병리학회지
    • /
    • 제21권3호
    • /
    • pp.736-740
    • /
    • 2007
  • Acanthopanax sessiliflorus SEEM extracts(AS) have been used to treat patient with diseases including cancer in Oriental countries. Recently, AS was known to have anti-cancer and immuno-stimulating activites. For these reasons, we investigated the effects of AS following gamma-ray irradiation on cytotoxicity for solid tumor cell line (S-180) and immune-potentiating ability such as proliferation of thymocytes and splenocytes. Finally we also investigated tumor weight and survival rate in tumor bearing mice. In our results, Treatment with AS suppressed proliferation of solid tumor cells (S-180) effectively. Treatment with AS accelerated thymocyte and splenocyte proliferation in tumor bearing mice. In addition, Treatment with AS reduced tumor weight and prolonged life of tumor bearing mice. In conclusion, we demonstrate that AS following gamma-ray irradiation is useful to treat patients with cancer, and also demonstrate that AS have both direct cytotoxic ability for cancer cells and indirect immune-stimulating action for thymocytes and splenocytes.

MERGERS, COSMIC RAYS, AND NONTHERMAL PROCESSES IN CLUSTERS OF GALAXIES

  • SARAZIN CRAIG L.
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.433-438
    • /
    • 2004
  • Clusters of galaxies generally form by the gravitational merger of smaller clusters and groups. Major cluster mergers are the most energetic events in the Universe since the Big Bang. The basic properties of cluster mergers and their effects are discussed. Mergers drive shocks into the intracluster gas, and these shocks heat the intracluster gas. As a result of the impulsive heating and compression associated with mergers, there is a large transient increase in the X-ray luminosities and temperatures of merging clusters. These merger boost can affect X-ray surveys of clusters and their cosmological interpretation. Similar boosts occur in the strong lensing cross-sections and Sunyaev-Zeldovich effect in merging clusters. Merger shock and turbulence associated with mergers should also (re)accelerate nonthermal relativistic particles. As a result of particle acceleration in shocks and turbulent acceleration following mergers, clusters of galaxies should contain very large populations of relativistic electrons and ions. Observations and models for the radio, extreme ultraviolet, hard X-ray, and gamma-ray emission from nonthermal particles accelerated in these shocks will also be described. Gamma-ray observations with GLAST seem particularly promising.

진단용(診斷用) X선장치(線裝置)의 총여과(總濾過)에 관(關)한 조사연구(調査硏究) (A Study of Total Filtration of the Diagnostic X-ray Equipments)

  • 김영일;경광현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.47-52
    • /
    • 1984
  • This paper was performed research for the total filtration in the useful beam of 45 diagnostic x-ray equipments using in Korea. We obtained the following results: 1. A good ability of total filtration was showed in higher than lower maximum permissible rating equipments. 2. In 53 percentage of 45 diagnostic x-ray equipments, the total filtration in the useful x-ray beam was not less than the values given in the Korean industrial standard. This results suggested to user to need the more ability management of diagnostic x-ray equipments using now.

  • PDF

Computational Astrophysics: Connecting Laboratory Experiments to Observations

  • Kwak, Kyujin
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.65.5-66
    • /
    • 2017
  • In the history of astronomy, observed data were interpreted very frequently based upon data measured at laboratories. For example, all the spectroscopic observations were understood via spectroscopic measurements on nuclei, atoms, and molecules. Recently, computational astrophysics plays a role of bridging experimental data to observations, in particular via numerical modeling of complex astronomical phenomena. This presentation focuses on computational nuclear astrophysics that connects experimental data on nuclei to high-energy observation data obtained by X-ray and gamma-ray telescopes. As an example case, X-ray burst will be discussed. In this phenomenon, observed X-ray light curves and spectra can be modeled by stellar evolution calculations that take nuclear reactions of rare isotopes as input information. This presentation also works as an introduction to the following presentation that will provide more detailed discussion on the experimental aspect of X-ray burst.

  • PDF

유방촬영용 X선장치의 선질 특성 (Measurement of X-ray Quality in Mammography Unit)

  • 이인자;김정민;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권2호
    • /
    • pp.5-10
    • /
    • 1998
  • In the mammography, X-ray beam quality is one of the most important factors. Using X-ray mammography unit model GE/CGR Senography 600T Senix H.F, Authors studied four subjects. 1. The aluminum attenuation rate in 30 kVp when used with or without compression plate. 2. HVLs at 5 different area of the X-ray field of $26{\sim}32kVp$. 3. HVLs to know the influence of corrected measurement or parallel measurement. 4. Film density with microdensitometer along and cross to the long axis of X-ray tube, in terms of the Heel effect in the X-ray field. The following results were obtained. 1. Beam quality of anode area was harder than cathode area. 2. The dose reduction rate of compression plate was approximately $65.5%{\sim}88.1%$ and the beam quality with compression plate was hardened up to 4kVp accordingly. 3. If the X-ray beam enters the attenuation plate obliquely, HVL was $2.6{\sim}2.9%$ harder than perpendicular to it. 4. Because of heel effect, the film density of cathode area is higher than anode area to film density of 0.5.

  • PDF

차량 네트워크 시스템을 위한 노드 매핑 기반 FlexRay-CAN 게이트웨이 구현 (Implementation of Node Mapping-based FlexRay-CAN Gateway for In-vehicle Networking System)

  • 배용경;김만호;이석;이경창
    • 한국자동차공학회논문집
    • /
    • 제19권6호
    • /
    • pp.37-45
    • /
    • 2011
  • As vehicles become more intelligent, in-vehicle networking (IVN) systems such as controller area network (CAN) or FlexRay are essential for convenience and safety of drivers. To expand the applicability of IVN systems, attention is currently being focused on the communication between heterogeneous networks such as body networking and chassis networking systems. A gateway based on message mapping method was developed to interconnect FlexRay and CAN networks. However, this type of gateways has the following shortcomings. First, when a message ID was changed, the gateway must be reloaded with a new mapping table reflecting the change. Second, if the number of messages to be transferred between two networks increase, software complexity of gateway increases very rapidly. In order to overcome these disadvantages, this paper presents FlexRay-CAN gateway based on node mapping method. More specifically, this paper presents a node mapping based FlexRay-CAN gateway operation algorithm along with the experimental evaluation for ID change.

X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(II) (A Study on Activities of Diagnostic X-ray Examination(II))

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.44-54
    • /
    • 1978
  • This study was carried out with statistical materials during the last two years of period from Jan. 1975 to Dec. 1976 which presented at radiologic department of 5 hospitals in Seoul City. The primary purpose of this study was to obtained more detailed informations related to the activities of radiologic technologists in diagnostic X-Ray examinations part and to provide some basic materials for managements in activities of then and manpower managements of their organization and practice. From the results of this study, the following conclusions were obtained [1] During two year from the January of 1975 to the December of 1976, total number of case in X-ray examinations were 464,830 case and 22,029 case in 1975 and 24,461 in 1976. And ratio of icreased in X-Ray examinations by year was 11.09 per cent. [2] Regarding the examined portion of X-Ray examination, a great propotion was chest examination as 56.88 per cent. [3] An average, the required time per case in X-Ray exam. was 9.28 minutes and make used of 1.94 sheets of X-Ray film per case in radiography. [4] An average, ratio of increased in X-Ray film by year was 12.71 per cent and ratio of failed film in it was 2.23 per cent. [5] The frequency rate of film size showed the highest distribution of $8"{\times}10"$(28.17%) and the highest distribution of X-Ray film by month was July(8.93%). [6] An average, the amount of activities per a diagnostic X-Ray equipment was 34.92 case and make used of 67.81 sheets of X-Ray film in a day. [7] The mean number of case in X-Ray examinations by radiologic technologists was 29.29 cases and make used of 56.87 sheets of X-Ray film in a day. Also, the average number of case was reading by radiologists was 32.42 case and 62.97 sheets of X-Ray film in a day.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • 나길주;백수웅;양현훈;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

랜덤 포레스트를 이용한 X-선 혈관조영영상에서의 혈관 자동 영역화 알고리즘 (An Automatic Algorithm for Vessel Segmentation in X-Ray Angiogram using Random Forest)

  • 정성희;이수찬;심학준;정호엽;허용석;장혁재
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.79-85
    • /
    • 2015
  • The purpose of this study is to develop an automatic algorithm for vessel segmentation in X-Ray angiogram using Random Forest (RF). The proposed algorithm is composed of the following steps: First, the multiscale hessian-based filtering is performed in order to enhance the vessel structure. Second, eigenvalues and eigenvectors of hessian matrix are used to learn the RF classifier as feature vectors. Finally, we can get the result through the trained RF. We evaluated the similarity between the result of proposed algorithm and the manual segmentation using 349 frames, and compared with the results of the following two methods: Frangi et al. and Krissian et al. According to the experimental results, the proposed algorithm showed high similarity compared to other two methods.

아연의 가열온도와 표면 거칠기가 원적외선 복사량에 미치는 영향 (Effects of Temperature and Surface Roughness of Zinc on the Far-Infrared Ray Emissivity)

  • 장충근;임진석;김원사
    • 한국광물학회지
    • /
    • 제12권2호
    • /
    • pp.96-100
    • /
    • 1999
  • Effects of surface conditions (temperature and roughness) of test specimens, when measuring emissive power of far-infrared ray, have been investigated using FT-IR spectrometer. Element metal zinc (Zn) was selected in this study as representative specimen of materials consisting of simple element. The zinc specimens were heated to four temperatures, i.e., 333K, 353K, .373K, and also their surface was finished with SiC abrasive papers of 100, 220, 360, 400, 600, 800, and 1000 mesh in size. The results shows that the emissive power (W/㎡) of the far-infrared ray increases with temperature for a given roughness and its relationship may be expressed by the following equations: Yη=1.0=0.142$.$T-0.937 for η=1.0, and Yη=10=0.016$.$T-1.286 for η=10. The emissive power is also known to increase with surface roughness for a given temperature. Their relationship can be represented by the following equations: YT=313K=0.234$.$$\ell$n(η)+3.53, at 313K, YT=353K=0.234$.$$\ell$n(η)+4.02 at 353K and YT=393K=0.243$.$$\ell$n(η)+4.62 at 393K.

  • PDF