• Title/Summary/Keyword: range detector

Search Result 817, Processing Time 0.035 seconds

Signal Shapes from a Closed-ended Coaxial HPGe Detector

  • Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.451-458
    • /
    • 1997
  • Signal shapes from a closed-ended coaxial HPGe detector are investigated by numerical methods. The detector used in this study has a volume of 72 ㎤ with relative efficiency of 15%. The electric field and potential distributions in the detector are determined by solving the Poisson equation at the depletion and operating bias. Hence the time dependent signal shapes induced on the electrode are obtained from the energy balance consideration and tv solving the equation of motion for the charge carriers. For various initial positions of a charge carrier pair, the collection times of induced charge vary in the range of 70 - 404 nsec.

  • PDF

Characterization of saturation of CR-39 detector at high alpha-particle fluence

  • Ghazaly, M. El;Hassan, Nabil M.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.432-438
    • /
    • 2018
  • The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from $0.06{\times}10^8$ to $7.36{\times}10^8\;alphas/cm^2$ from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of $70^{\circ}C$ for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV-Visible (UV-Vis) absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of $4.05{\times}10^8$, $5.30{\times}10^8$, and $7.36{\times}10^8\;alphas/cm^2$. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs) in measurement of high fluence of heavy ions as well as in radiation dosimetry.

Detection of Faces Located at a Long Range with Low-resolution Input Images for Mobile Robots (모바일 로봇을 위한 저해상도 영상에서의 원거리 얼굴 검출)

  • Kim, Do-Hyung;Yun, Woo-Han;Cho, Young-Jo;Lee, Jae-Jeon
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.4
    • /
    • pp.257-264
    • /
    • 2009
  • This paper proposes a novel face detection method that finds tiny faces located at a long range even with low-resolution input images captured by a mobile robot. The proposed approach can locate extremely small-sized face regions of $12{\times}12$ pixels. We solve a tiny face detection problem by organizing a system that consists of multiple detectors including a mean-shift color tracker, short- and long-rage face detectors, and an omega shape detector. The proposed method adopts the long-range face detector that is well trained enough to detect tiny faces at a long range, and limiting its operation to only within a search region that is automatically determined by the mean-shift color tracker and the omega shape detector. By focusing on limiting the face search region as much as possible, the proposed method can accurately detect tiny faces at a long distance even with a low-resolution image, and decrease false positives sharply. According to the experimental results on realistic databases, the performance of the proposed approach is at a sufficiently practical level for various robot applications such as face recognition of non-cooperative users, human-following, and gesture recognition for long-range interaction.

  • PDF

Novel Fast Peak Detector for Single- or Three-phase Unsymmetrical Voltage Sags

  • Lee, Sang-Hoey;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.658-665
    • /
    • 2011
  • In the present paper, a novel fast peak detector for single- or three-phase unsymmetrical voltage sags is proposed. The proposed detector is modified from a single-phase digital phase-locked loop based on a d-q transformation using an all-pass filter (APF). APF generates a virtual phase with $90^{\circ}$ phase delay. However, this virtual phase cannot reflect a sudden change of the grid voltage in the moment of voltage sag, which causes a peak value to be significantly distorted and to settle down slowly. Specifically, the settling time of the peak value is too long when voltage sag occurs around a zero crossing, such as phase $0^{\circ}$ and $180^{\circ}$. This paper describes the operating principle of the APF problem and proposes a modified all-pass filter (MAPF) to mitigate the inherent APF problem. In addition, a new fast peak detector using MAPF is proposed. The proposed detector is able to calculate a peak value within 0.5 ms, even when voltage sag occurs around zero crossing. The proposed fast peak detector is compared with the conventional detector using APF. Results show that the proposed detector has faster detection time in the whole phase range. Furthermore, the proposed fast peak detector can be effectively applied to unsymmetrical three-phase voltage sags. Simulation and experimental results verify the advantages of the proposed detector and MAPF.

Design of a 6-bit 500MS/s CMOS A/D Converter with Comparator-Based Input Voltage Range Detection Circuit (비교기 기반 입력 전압범위 감지 회로를 이용한 6비트 500MS/s CMOS A/D 변환기 설계)

  • Dai, Shi;Lee, Sang Min;Yoon, Kwang Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.4
    • /
    • pp.303-309
    • /
    • 2013
  • A low power 6-bit flash ADC that uses an input voltage range detection algorithm is described. An input voltage level detector circuit has been designed to overcome the disadvantages of the flash ADC which consume most of the dynamic power dissipation due to comparators array. In this work, four digital input voltage range detectors are employed and each input voltage range detector generates the specific clock signal only if the input voltage falls between two adjacent reference voltages applied to the detector. The specific clock signal generated by the detector is applied to turn the corresponding latched comparators on and the rest of the comparators off. This ADC consumes 68.82mW with a single power supply of 1.2V and achieves 4.9 effective number of bits for input frequency up to 1MHz at 500 MS/s. Therefore it results in 4.75pJ/step of Figure of Merit (FoM). The chip is fabricated in 0.13-um CMOS process.

Development of Radiation Thermometer using InSb Photo-detector (인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구)

  • Hwang, Byeong-Oc;Lee, Won-Sik;Jhang, Kyung-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF

The Design of Capacitance Variation Detector for the Obstacle Detection System (방해물 감지 장치용 캐패시턴스 변화 감지기의 설계)

  • Kim, Jae-Min;Song, Yun-Seob;Yi, Sang-Yeoul;Kim, Soo-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.133-138
    • /
    • 2004
  • Today, the obstacle detection system has massive size and restrictive detection range. To solve these problems, this paper proposes the capacitance variation detector using the variated capacitance value as a result of the obstacle approaching. If obstacle approaches, the capacitance value of capacitance sensor is increased and the operating frequency of oscillator is decreased. Then this changed frequency appears to the output of the mixer that operate down conversion. The capacitance variation detector is produced by Hynix$0.35{\mu}$ CMOS process. In experiment result, the frequency of final output is 6.81 MHz at no obstacle and 31.45 MHz at approaching obstacle. In conclusion, proposed capacitance variation detector has small size, low power consumption and easiness to set up anywhere. So it is expected to substitute the obstacle detector.

A Study on the Dynamic Range Performance Evaluation Method of Detector with Variation of Tube Voltage and Automatic Exposure Control (AEC) in Digital Radiography (DR) -Focused on the Dynamic Step Wedge and Histogram Evaluation (DR(Digital Radiography)에서 관전압 및 자동노출제어장치의 감도 변화에 따른 검출기의 동적 범위 성능평가 방법연구 -Dynamic Step Wedge와 히스토그램 평가를 중심으로)

  • Hwang, Jun-Ho;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.4
    • /
    • pp.368-380
    • /
    • 2019
  • This study proposes a method to evaluate the performance of a detector by analyzing the dynamic step wedge and histogram according to the change of the tube voltage and sensitivity when using the Automatic Exposure Control (AEC). The performance of a detector was evaluated by measuring X-ray quality, Entrance Surface Dose (ESD), tube current, dynamic range corresponding to detector sensitivities of S200, S400, S800, S1000 per tube voltage of 60, 70, 81, 90 kVp. As a results, all of the qualities satisfied the acceptance criteria, and the Entrance Surface Dose and tube current were decreased stage by stage as sensitivity was set higher. In the dynamic step wedge, the observable dynamic range has also increased as tube voltage became higher. The histogram showed the quantization separation phenomena as the tube voltage was set higher. The higher the sensitivity, the more the underflow and overflow occurred in which the amount of information on both ends of the histogram was lost. In conclusion, the deterioration in the performance of the detector was found to be insufficient to realize the change of the tube voltage and sensitivity when using the Automatic Exposure Control, and it is useful to use dynamic step wedge and histogram in evaluating detector performance evaluation.

Fast Lock-Acquisition DLL by the Lock Detection (Lock detector를 사용하여 빠른 locking 시간을 갖는 DLL)

  • 조용기;이지행;진수종;이주애;김대정;민경식;김동명
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.963-966
    • /
    • 2003
  • This paper proposes a new locking algorithm of the delay locked loop (DLL) which reduces the lock-acquisition time and eliminates false locking problem to enlarge the operating frequency range. The proposed DLL uses the modified phase frequency detector (MPFD) and the modified charge pump (MCP) to avoid the false locking problem. Adopting a new lock detector that measures delay between elects helps the fast lock-acquisition time greatly. The idea has been confirmed by HSPICE simulations in a 0.35-${\mu}{\textrm}{m}$ CMOS process.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF