• Title/Summary/Keyword: ramp

Search Result 862, Processing Time 0.029 seconds

Discharge Characteristic Analysis with a Ramp Reset Waveform Using 2-Dimensional Simulation in the PDP (AC PDP에서 2차원 수치해석을 이용한 Ramp Reset 구동파형에 따른 방전 특성 분석)

  • Park, Suk-Jae;Choi, Hoon Young;Seo, Jeong-Hyun;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.192-194
    • /
    • 2003
  • In this paper, we present a 2-Dimensional simulation model of the discharge in an ac plasma display panel cell. Therefore, we study a ramp reset waveform in an ac plasma display panel discharge cell using 2-Dimensional simulation. Finally We research a connection between priming particles' density and stability.

  • PDF

Junction, Circuit and System Developments for a High-Tc Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.13-15
    • /
    • 1999
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

Developement of an Optimization Model for Freeway Entrance-Ramp Metering (고속도로시스템의 정주기식 램프미터링을 위한 최적화모형의 개발)

  • 김영찬;빈미영
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.4
    • /
    • pp.117-132
    • /
    • 1995
  • Peak-period congestion is a frequent occurrence on many freeways. Entrance-metering is an effective strategey in improving urban freeway traffic condition. This paper describes the prodecure to develop a computer program for proparing optimum ramp-metering stategies. Four existing ramp-metering optimaization models wer reviewed and evaluated in regared to their theories and actural performances. A optimization model was proposed in this paper. Final model takes aform of quadratic programming. The performance of the propeosed model wastest using FREFLO.

  • PDF

Evaluation of Analysis Methodologies for Freeway Ramp Areas (고속도로 연결로 분석기법에 대한 평가)

  • 이정수;윤치환;김은연
    • Journal of Korean Society of Transportation
    • /
    • v.10 no.1
    • /
    • pp.5-20
    • /
    • 1992
  • Even though the types of ramp facilities in Korea are not various like other countries operations in these sections are very important because ramp merging and /or diverging flow affects freeway overall sections. In this study existing methodologies especially the gap acceptance model and the regression model in USHCM are evaluated with our field data. By gap acceptance model the merging capacity is founded 2.360 pcph which is increased by 7% than the capacity of freeway basic section. And in comparison of actual lane 1 volume to the estimation volume by HCM model the model slightly overestimates the actual volue.

  • PDF

Time-domain Approaches for Input Disturbance Observer

  • Kim, Kyung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.22-25
    • /
    • 2005
  • In the paper, algorithms for disturbance observers are newly presented in the time-domain. Attention is paid to observing a ramp disturbance by introducing an integral term to the output equation of a constant disturbance observer. In order to reduce the sensitivity to the measurement noise, the disturbance observer is combined with the state observer. It will be shown that the estimation dynamics can be arbitrarily chosen by assigning the eigenvalues of a characteristic equation. Also, we provide the analysis of observer behaviors subject to non-ramp-style disturbances. Finally, we propose the generalized disturbance observer that accurately estimates disturbances of higher order in time series expansion.

  • PDF

A Study on Endpoint Detection and Syllable Segmentation System Using Ramp Edge Detection (Ramp Edge Detection을 이용한 끝점 검출과 음절 분할에 관한 연구)

  • 유일수;홍광석
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2216-2219
    • /
    • 2003
  • Accurate speech region detection and automatic syllable segmentation is important part of speech recognition system. In automatic speech recognition system, they are needed for the purpose of accurate recognition and less computational complexity, In this paper, we Propose improved syllable segmentation method using ramp edge detection method and residual signal Peak energy. These methods were used to ensure accuracy and robustness for endpoint detection and syllable segmentation system. They have almost invariant response to various background noise levels. As experimental results, we obtained the rate of 90.7% accuracy in syllable segmentation in a condition of accurate endpoint detection environments.

  • PDF

Junction, Circuit and System Developments for a High-$T_c$ Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.81-84
    • /
    • 2000
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

New Ramp-reset Waveform for Fast Addressing in AC-PDPs

  • Kim, Oe-Dong;Ahn, Byoung-Nam;Choi, Kwang-Yeol;Yoo, Eun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.643-646
    • /
    • 2005
  • We present new ramp-reset waveforms that realize fast addressing in AC-PDPs. These waveforms distort the distribution of wall charges on the surface of a phosphor layer: hence, the enhanced electric field helps to ignite a cell faster. They also reduce the black luminance: the divide of erasing ramp down discharges into two parts, i.e. a surface discharge and a vertical discharge, makes lower luminance.

  • PDF

A P-Parallel Controller Design based on P-Control Ramp Response in Machine Tool (비례제어 경사응답에 기반한 공작기계의 비례-병렬 제어기 설계)

  • Gil, Hyeong-Gyeun;Lee, Gun-Bok
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.780-785
    • /
    • 2004
  • The work presented here deals with controller design by graphical method based on proportional control ramp response. The design aims at the improvement of transient response, disturbance rejection capability, steady-state error reduction with stability preservation. The first step is to generate tracking-error curve with proportional control only and decide the added error signal shape on the error curve. The effectiveness of the proposed controller is confirmed through the simulation and experiment.

  • PDF

Ramp-rate limitation of CIC(Cable-In-Conduit) superconducting magnet (관내권선(Cable-In-Conduit, CIC) 초전도 자석(Superconducting magnet)에서의 한계 자속 변화(ramp-rate limitation) 현상)

  • Jeong, Sang-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.37-40
    • /
    • 1996
  • Cable-In-Conduit Conductor(CICC) is widely accepted as an advanced superconductor configuration for large scale applications such as tokamak fusion reactors, MAGLEV (MAGnetic LEVitation), and SMES (Superconducting Magnetic Energy Storage). The stability of CICC cooled with supercritical helium can be very high if it is operated below a certain limiting current. This limiting current can be determined by Stekly type heat balance equation. The stability characteristic of CICC for AC operation is more complicated than that of DC because there are additional instability sources which are associated with local flux change. Ramp-rate limitation is a phenomenon discovered during US-DPC (United States-Demonstration Poloidal Coil) program, which showed apparent quench current degradation associated with high dB/dt. This paper describes recent experimental investigation results on the ramp-rate limitation and discusses current imbalance, induced current, current redistribution due to local quench of the strand in the cable.

  • PDF