• Title/Summary/Keyword: radiation effect

Search Result 3,606, Processing Time 0.024 seconds

Radiation Effects on Fiber Bragg Grating Sensors by Irradiation Conditions of UV Laser (UV 레이저 노출조건에 따른 FBG 센서의 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2310-2316
    • /
    • 2016
  • We studied the effect of $Co^{60}$ gamma-radiation on the fiber Bragg gratings (FBGs) by irradiation time of UV Krypton fluoride (KrF) excimer laser among grating processing parameters. The FBGs were fabricated in a different UV laser irradiation time at 30, 60, 90, and 120 seconds using the same commercial Ge-doped silica core fiber (SMF-28e). It was exposed to gamma-radiation up to a high dose of 34.3 kGy at the dose rate of 106 Gy/min, and then it was analyzed radiation effects by measuring the radiation-induced change in the temperature sensitivity coefficient and Bragg wavelength shift. According to the experimental results, We confirmed that the UV laser irradiation period for grating inscription has a highly effect on the radiation sensitivity of the FBGs. The radiation-induced Bragg wavelength shift by the change of laser irradiation conditions showed a difference more than about 50 %.

A Study of Scattered Radiation Effect on Digital Radiography Imaging System (디지털 방사선영상 시스템에서 산란선이 영상 품질에 미치는 영향)

  • Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.71-78
    • /
    • 2017
  • Scattered radiation is inherent phenomenon of x-ray, which occurs to the subject (or patient). Therefore it cannot be avoidable but also interacts as serious noise factor because the only meaningful information on x-ray radiography is primary x-ray photons. The purpose of this study was to quantify scattered radiation for various shooting parameters and to verify the effect of anti-scatter grid. We employed beam stopper method to characterize scatter to primary ratio. To evaluate effect on the projection images calculated contrast to noise ratio of given shooting parameters. From the experiments, we identified the scattered radiation increases in thicker patient and smaller air gap. Moreover, scattered radiation degraded contrast to noise ratio of the projection images. We find out that the anti-scatter grid rejected scattered radiation effectively, however there were not fewer than 100% of scatter to primary ratio in some shooting parameters. The results demonstrate that the scattered radiation was serious problem of medical x-ray system, we confirmed that the scattered radiation was not considerable factor of dig ital radiog raphy.

Effect of a Finite Square Substrate Plane on the Radiation Characteristics of a Microstrip Patch Antenna (유한한 정사각형 기판의 크기가 마이크로스트립 패치 안테나의 방사 특성에 미치는 영향)

  • Park, Jae-Woo;Kim, Tae-Young;Kim, Boo-Gyoun;Shin, Jong-Dug
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.2
    • /
    • pp.114-125
    • /
    • 2009
  • Effect of a finite square substrate plane on the radiation characteristics of a microstrip patch antenna is investigated. Effect of a finite square substrate plane on the resonance frequency and bandwidth is very small, while that on the radiation pattern is very large. The gain of front radiation and the direction of the maximum gain vary almost periodically with the length of a square substrate plane. The length of a square substrate plane for the maximum gam and the minimum gain of front radiation decrease as the electrical thickness of a substrate increases. The variation of the gain of front radiation with the length of a square substrate plane increases as the electrical thickness of a substrate increases. The variation of the radiation pattern with the length of a square substrate plane is almost determined by the electrical thickness of a substrate.

SORET AND ELECTROMAGNETIC RADIATION EFFECT OF MHD MICRO POLAR FLUID PAST A POROUS MEDIUM IN THE PRESENCE OF CHEMICAL REACTION

  • SHEEBA JULIET S.;VIDHYA, M.
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.5
    • /
    • pp.1085-1102
    • /
    • 2023
  • In this study the magneto hydrodynamic (MHD) micro polar fluid flow of a viscous incompressible fluid past a porous medium in the presence of chemical reaction is considered. This work is devoted to investigate the Soret effect and Electromagnetic radiation effect and analyze analytically. In the energy equation the applied magnetic field strength and in the concentration equation the Soret effect are incorporated. The basic PDE (partial differential equations) are reduced to ODE (ordinary differential equations) using non dimensional variables. Then the analytical solution of the dimensionless equations are found using perturbation technique. The features of the fluid flow parameters are analyzed, discussed and explained graphically. The graphical solutions are found using MATLAB R2019b. Skin friction coefficient at the wall, Couple stress coefficient at the plate and the local surface heat flux are also thoroughly examined. Overall, this study sheds light on the complex interplay between physical parameters in the behavior of MHD micro-polar fluid past a porous medium in the presence of chemical reaction.

Effect of the Patch Length and Via Radius on the Radiation Characteristics of an Inductive Loaded Patch Antenna (패치의 길이와 비아의 반경이 Inductive Loaded Patch Antenna의 방사 특성에 미치는 영향)

  • Kwak, Eun-Hyuk;Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.6
    • /
    • pp.48-56
    • /
    • 2012
  • Radiation characteristics of inductive loaded patch antennas (ILPAs) and conventional patch antennas using a half wavelength resonance mode for substrates with various dielectric constants are investigated. ILPAs have the good radiation characteristics such as high broadside gain and suppressed radiation along the horizontal plane compared to those of conventional patch antennas. We show that ILPAs with the appropriate patch length and via radius have the optimum radiation characteristics such as the highest broadside gain and the most suppressed horizontal radiation.

Space Radiation Measurement on the Polar Route onboard the Korean Commercial Flights

  • Hwang, Jung-A;Lee, Jae-Jin;Cho, Kyung-Suk;Choi, Ho-Sung;Rho, Su-Ryun;Cho, Il-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.1
    • /
    • pp.43-54
    • /
    • 2010
  • This study was performed by the policy research project of Ministry of Land, Transport and Maritime Affairs, which title is "Developing safety standards and management of space radiation on the polar route". In this research, total six experiments were performed using Korean commercial flights (B747). Three of those are on the polar route and the other three are on the north pacific route. Space radiation exposure measured on the polar route is the average 84.7 uSv. The simulation result using CARI-6M program gives 84.9 uSv, which is very similar to measured value. For the departure flight using the north pacific route, the measured space radiation is the average 74.4 uSv. It seems that is not so different to use the polar route or not for the return flight because the higher latitude effect causing the increase of space radiation is compensated by the shortened flight time effect causing decreasing space radiation exposure.

A Study on the Radiation Forces Acting on a Submerged-Plate (몰수평판에 작용하는 Radiation 유체력에 관한 연구)

  • Lee, Sang-Min;Kong, Gil-Young;Kim, Chol-Seong
    • Journal of Navigation and Port Research
    • /
    • v.28 no.3
    • /
    • pp.199-205
    • /
    • 2004
  • We have developed a composite grid method for the solution of the radiation problem We divide the domain into two different grids; one is a moving grid system and the other is a fixed grid system. This numerical method is applied to calculation of the radiation forces generated by the submerged plate oscillating near a free surface. The experimental data are compared with the numerical ones obtained by the present method and a linear potential theory. As a result, we can confirm the accuracy of the present method. Finally, Lie have evaluated the effect of nonlinear and viscous damping on the hydrodynamic forces acting on the submerged plate.

Effect of quercetin on impaired immune function in mice exposed to irradiation

  • Jung, Ji-Hye;Kang, Ji-In;Kim, Hyun-Sook
    • Nutrition Research and Practice
    • /
    • v.6 no.4
    • /
    • pp.301-307
    • /
    • 2012
  • Radiation used in cancer treatment may cause side effects such as inflammation. Quercetin is a polyphenol that reduces inflammation. This study evaluated the recovery efficacy of quercetin on impaired immune function in irradiation-induced inflammatory mice. Quercetin administered at two concentrations of 10 and 40 mg/kg body weight was initiated 2 weeks before irradiation and was continued 30 days after irradiation. The animals exposed/not exposed to radiation were sacrificed on radiation days 10 and 30. Splenocyte proliferation, which was diminished after irradiation, was enhanced significantly by quercetin supplementation after 30 days of irradiation. Cytokine secretion increased in the radiation group compared to that in the non-radiation control group. After 30 days of radiation, interleukin (IL)-$1{\beta}$ and IL-6 secretion decreased significantly in the radiation-quercetin groups. When quercetin was administered for 44 days, it showed a possible protective effect against irradiation-induced inflammation in mice. Quercetin could be beneficial in the recovery of irradiation-induced increases in cytokine secretion.

BETTER UNDERSTANDING OF THE BIOLOGICAL EFFECTS OF RADIATION BY MICROSCOPIC APPROACHES

  • Kim, Eun-Hee
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.551-560
    • /
    • 2008
  • Radiation has stochastic aspects in its generation, its choice of interaction mode during traveling in media, and its impact on living bodies. In certain circumstances, like in high dose environments resulting from low-LET radiation, the variance in its impact on a target volume is negligible. On the contrary, in low dose environments, especially when they are attributed to high-LET radiation, the impact on the target carries with it a large variance. This variation is more significant for smaller target volumes. Microdosimetric techniques, which have been developed to estimate the distribution of radiation energy deposited to cellular and subcellular-sized targets, contrast with macrodosimetric techniques which count only the average value. Since cells and DNA compounds are the critical targets in human bodies, microdosimetry, or dose estimation by microscopic approach, helps one better analyze the biological effects of radiation on the human body. By utilizing microbeam systems designed for individual cell irradiation, scientists have discovered that human cells exhibit radiosensitive reactions without being hit themselves (bystander effect). During the past 10 or more years, a new therapeutic protocol using discontinuous multiple micro-slit beams has been investigated for its clinical application. It has been suggested that the beneficial bystander effect is the essence of this protocol.

Radiation testing of low cost, commercial off the shelf microcontroller board

  • Fried, Tomas;Di Buono, Antonio;Cheneler, David;Cockbain, Neil;Dodds, Jonathan M.;Green, Peter R.;Lennox, Barry;Taylor, C. James;Monk, Stephen D.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3335-3343
    • /
    • 2021
  • The impact of gamma radiation on a commercial off the shelf microcontroller board has been investigated. Three different tests have been performed to ascertain the radiation tolerance of the device from a nuclear decommissioning deployment perspective. The first test analyses the effect of radiation on the output voltage of the on-board voltage regulator during irradiation. The second test evaluated the effect of gamma radiation on the voltage characteristics of analogue and digital inputs and outputs. The final test analyses the functionality of the microcontroller when using an external, shielded voltage regulator instead of the on-board voltage regulator. The results suggest that a series of latch-ups occurs in the microcontroller during irradiation, causing increased current drain which can damage the voltage regulator if it does not have short-circuit protection. The analogue to digital conversion functionality appears to be more sensitive to gamma radiation than digital and analogue output functionality. Using an external, shielded voltage regulator can prove beneficial when used for certain applications. The collected data suggests that detaching the voltage regulator can extend the lifespan of the platform up to approximately 350 Gy.