간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구 (Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography)

  • 민정환;정회원;김기원;권경태;정재용;손진현;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

Cortex-A8을 이용한 휴대용 감마선 검출 플랫폼 구현 (An implementation of portable gamma ray detection platform using Cortex-A8)

  • 서재길;이윤호;김영길
    • 한국정보통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.1028-1033
    • /
    • 2013
  • 전 세계적으로 해운물류 안전 보안체계가 강화됨에 따라 물류보안 체계구축을 위한 유비쿼터스 기술 기반의 해운물류 안전 보안 핵심기술 개발이 이루어지고 있다. 우리나라의 물류보안제도를 살펴보면 물류보안확보에 필수적인 기술 및 장비 개발이 이루어지지 않아 향후 선진국에 기술 종속 우려가 있다. 앞으로 물류 전 구간을 완벽하게 통합하는 물류보안제도를 도입하는 것이 시급하다. 이에 따라서 안전 보안 체계강화를 위한 감마선 핵종을 검출할 수 있는 휴대용 방사선 검출 장치의 개발 필요성이 높아지고 있다. 본 논문에서는 Cortex-A8을 이용한 휴대용 방사선 검출 장치 플랫폼 구현에 대한 연구를 제안하고자 한다.

Broad Beam Gamma-Ray Spectrometric Studies with Environmental Materials

  • El-Kateb, Abdul-Hamid Hussein
    • Journal of Radiation Protection and Research
    • /
    • 제43권2호
    • /
    • pp.75-84
    • /
    • 2018
  • Background: Gamma-ray spectrometry helps in radiation shielding problems and different applications of radioisotopes. Experimental arrangements including broad beam geometries are widely used. The aim is to investigate and evaluate the ${\gamma}-ray$ spectra via attenuation by environmental materials. Materials and Methods: The photo peak to nominated parts in the ${\gamma}-ray$ spectra and the attenuation coefficients ${\mu}_b/{\rho}$ from broad beam geometries are measured for the materials water, soil, sand and cement at the energies 0.662, 1.25, and 1.332 MeV with a $3{^{\prime}^{\prime}}{\times}3{^{\prime}^{\prime}}$ NaI(Tl) detector. Results and Discussion: The ${\gamma}-ray$ spectra vary according to changes in the effective atomic number $Z_{eff}$ of the attenuator, the photon energy and the solid angle. The peak to total ratios are the most sensitive parts to variations in the experimental conditions and overturn in the region 0.663 MeV to 1.332 MeV. This is indicated as inversion trend. The results are discussed in view of $Z_{eff}$ and the experimental conditions. The intensity build-up is larger at the lower energy and larger scattering angles in agreement with Klein-Nishina formula and other results. The build-up factor B is$${\sim_=}$$1 at high ${\gamma}-energies$ and small scattering angles. Conclusion: The sensitivity to material characteristics decrease gradually from peak: to total, to Compton valley, to Compton plateau ratios. Rigorous collimation is necessary at small energies. Cement, of the largest $Z_{eff}$, is characterized by the maximum broad beam mass attenuation coefficients ${\mu}_b/{\rho}$. The obtained results provide information to decide for the suitable experimental set-up based on aim of the work.

선형가속기의 소조사면에 대한 빔 자료 측정에서 검출기의 선량 특성 분석 (Dosimetric Characteristics of Detectors in Measurement of Beam Data for Small Fields of Linear Accelerator)

  • 구기래;양오남;임청환;최원식;신성수;안우상
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권3호
    • /
    • pp.265-273
    • /
    • 2012
  • 선형가속기를 기반으로 하는 세기조절방사선치료와 정위적방사선수술에서는 치료계획시스템의 소조사면에 대한 신뢰할만한 선량분포를 계산하기 위해서는 우선적으로 소조사면의 정확한 빔 자료 측정이 선행되어야 한다. 특히 소조사면의 빔 자료 측정에서 조사면 가장자리에서의 급격한 선량 변화, 측면 전자비평형, 그리고 검출기의 체적 영향으로 인한 적절한 검출기 선택이 중요하다. 따라서 본 연구에서는 선형가속기의 소조사면에 대한 빔 자료 측정에 있어서 검출기의 선량 특성을 알아보고자 하였다. 검출기는 0.01 cc 부피와 0.13 cc 부피의 이온전리함과 정위적다이오드를 사용하였으며, 빔 자료는 광자선(6 MV와 15 MV)에 대하여 조사면 크기를 $2{\times}2cm^2$에서 $5{\times}5cm^2$까지 변화시켜 각 검출기를 이용하여 깊이선량백분율, 선량출력계수, 그리고 빔측면도를 측정하였다. CC01 이온전리함과 정위적다이오드 검출기를 이용한 $PDD_{20}/PDD_{10}$$2{\times}2cm^2$ 조사면의 경우 6 MV와 15 MV에서 각각 1.02%와 0.12% 차이를 보였다. $3{\times}3cm^2$ 이상의 조사면에서는 각 검출기를 이용하여 얻어진 $PDD_{20}/PDD_{10}$의 차이가 6 MV와 15 MV에서 각각 평균 1.15%와 0.71% 이였다. CC01 이온전리함과 정위적다이오드 검출기를 이용한 선량출력계수 측정 결과, $2{\times}2cm^2$ 조사면의 경우 6 MV와 15 MV에서 0.5%와 1.5%이내에서 일치하였다. $3{\times}3cm^2$ 이상의 조사면에서는 각 검출기의 차이가 0.5% 이내이였다. 3개의 깊이에서 측정된 빔측면도의 반음영은 정위적다이오드 검출기의 경우 6 MV와 15 MV에서 각각 평균 2.7 mm와 3.5 mm, CC01 이온전리함의 경우 각각 평균 3.4 mm와 4.3 mm, CC13 이온전리함의 경우 각각 평균 5.2 mm와 6.1 mm이였다. 이를 통해 깊이선량백분율과 선량출력계수 측정 시 $2{\times}2cm^2$ 조사면에서는 CC01 이온전리함과 정위적다이오드 검출기를 $3{\times}3cm^2$에서 $5{\times}5cm^2$ 조사면에서는 각 검출기의 사용이 가능할 것으로 판단된다. 또한 소조사면에 대한 정확한 빔측면도의 반음영을 측정하기 위해서는 유효체적이 작은 CC01 이온전리함과 정위적다이오드 검출기 사용하는 것이 타당하겠다.

방사성 오염도 측정을 위한 광섬유 검출기 제작 (Fabrication of Fiber-optics Detector for Measuring Radioactive Waste)

  • 김정호;주관식
    • 전기전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.282-287
    • /
    • 2015
  • 본 연구에서는 연구에서는 Ce:GAGG 섬광체, 광섬유 그리고 광전자증배관을 이용하여 광섬유 검출기를 제작하였다. 섬광체의 단결정 크기는 MCNPX 코드를 이용하여 섬광체 깊이에 따른 감마선 계수효율을 전산모사하여 $3{\times}3{\times}20mm^3$로 설정하였다. 제작된 검출기는 표준 감마선원인 $^{137}Cs$$^{133}Ba$을 이용하여 세기의 따른 선형성 평가와 거리 변화에 따른 계수량 변화 측정을 하였다. 그 결과 추세선식 R-square 값이 0.99741로 매우 좋은 응답선형성을 보였고, 거리에 따른 검출 특성 또한 MCNPX값과 비교하였을 때 2% 이하로 좋은 검출특성을 보였다. 또한 단일선원과 혼합선원에서의 감마선 에너지 분광 결과 $^{137}Cs$은 662keV에서 그리고 $^{133}Ba$은 356keV에서 감마선 에너지 피크를 확인하였다. 광섬유 검출기를 사용한다면 작업자의 작업시간과 피폭을 줄여줄 것으로 보인다.

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건 (Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography)

  • 이원정
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

스테레오 기반 감마선원 탐지 및 가시화에 관한 연구 (Study of the Radioactive Source Detection and the Visualization with the Stereo Radiation Detector)

  • 박강택;이남호;차한주
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1100-1102
    • /
    • 2015
  • 본 논문에서는 스테레오 기반 감마선원 탐지장치를 통해 감마선원을 포함하는 공간을 래스터 스캔방식으로 스캔하여 가시광영상과 감마선영상을 획득하고, 스테레오 감마선 탐지장치로부터 선원까지의 거리와 방향에 대한 3차원 정보 획득 및 가시화를 수행하였다. 탐지장치의 구성은 감마선원 탐지를 위한 방사선 검출부, 선원탐지를 위해 래스터스캔방식의 스캔을 위한 팬틸트 그리고 가시광영상을 위한 CCD 카메라로 이루어진다. 선원에 대한 공간분포를 측정하기 위해 스테레오 구조의 장치를 구현하였으며 스테레오 영상획득을 위해 CCD 카메라와 감마선 탐지장치는 각각 2대로 구성하였다. 탐지선원에 대한 분포를 나타내기 위해 감마선 탐지 장치와 가시광 카메라에 대한 보정을 수행하였고, 각각의 카메라에 대한 스테레오 보정을 수행한 후 가시광영상과 감마선영상 중첩을 통해 감마선원에 대한 분포를 나타내었다. 좌, 우 분포영상에 대한 정류화처리 후 스테레오 영상에 대한 가시화결과를 도출하였다.

  • PDF

Characterization of saturation of CR-39 detector at high alpha-particle fluence

  • Ghazaly, M. El;Hassan, Nabil M.
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.432-438
    • /
    • 2018
  • The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from $0.06{\times}10^8$ to $7.36{\times}10^8\;alphas/cm^2$ from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of $70^{\circ}C$ for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV-Visible (UV-Vis) absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of $4.05{\times}10^8$, $5.30{\times}10^8$, and $7.36{\times}10^8\;alphas/cm^2$. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs) in measurement of high fluence of heavy ions as well as in radiation dosimetry.

안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험 (Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection)

  • 곽성우;안길훈;박일진
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA는 핵물질 계량 관리 검사를 위해 다양한 방사선 검출기를 사용하고 있다. 주로 HPGe, NaI(Tl), CZT 등이 사용되며, 정확한 측정이 요구되는 검사에는 고분해능 HPGe 검출기 활용도가 높다. HPGe 검출기는 추가적인 냉각장치로 인하여 부피가 크고 무거우며, 사용하기 전에 충분히 냉각시켜야 하기 때문에 측정의 준비 시간이 많이 걸린다는 단점이 있다. 이러한 문제점을 해결하기 위해 가볍고 짧은 사용 전 냉각이 요구되는 휴대형 HPGe가 개발되었다. 본 논문은 개발된 휴대형 HPGe 검출기 시제품을 실제 IAEA 사찰 현장에 적용하여 얻은 성능평가 결과를 기술한다. 휴대형 HPGe로 얻은 방사선 스펙트럼은 핵물질 종류와 농축도에 따라 다른 특징을 보였고, 또한 $^{235}U$$^{238}U$의 붕괴 계열에서 방출되는 감마선 및 우라늄의 특성 x-선 차이도 확인할 수 있었다. 그리고 휴대형 HPGe 검출기 시제품으로 측정한 농축도는 핵물질 종류에 따라 실제값과 9 ~ 27%의 상대적 오차를 보였다. 휴대형이라는 소형 검출기의 한계 때문에 일부 핵물질은 IAEA에서 요구하는 정확도를 만족시키지 못하는 경우도 있었지만 향후 추가적인 연구의 수행으로 이러한 문제점은 해결 가능할 것으로 판단된다. 본 논문은 새로운 휴대형 HPGe 검출기를 안전조치에 적용한 사례와 측정한 스펙트럼을 농축도 분석 코드로 분석한 결과를 다룬다. 따라서 국내 원자력시설의 우라늄 농축도 검증을 위한 IAEA 안전조치 사찰 결과를 분석한 논문이 별로 발표되지 않은 상황에서, 본 논문은 안전조치 검사 결과 분석에도 유익할 것으로 판단된다. 개발된 방사선 검출기의 개선 사항도 함께 논의하였으므로 향후 관련 분야 방사선 검출기 개발에도 기여할 것으로 예상된다.