• Title/Summary/Keyword: protective film

Search Result 259, Processing Time 0.026 seconds

Surface Analysis of Cold Rolled Steel Sheets by X-ray Photoelectron Spectroscopy (X-ray Photoelectron Spectroscopy를 이용한 냉연 강판의 표면 분석 연구)

  • Lee, Do Hyung;So, Jae Choon
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.115-124
    • /
    • 1994
  • The corroded surface of cold rolled steel sheet in the process of rinsing after alkali-cleaning was examined by means of X-ray Photoelectron Spectroscopy(XPS). In addition, the surface-treated cold rolled steel with 0.05wt% $Na_5P_3O_{10}$ solution for the purpose of preventing the corrosion was examined by means of XPS and the results were compared with those for the non-treated cold rolled steel. It was found that the corroded surface consists of $Fe_2O_3$, FeO and $Fe(OH)_3$ and the thickness of the oxide layer is about $1500{\AA}$. On the other hand, in the case of surface-treated cold rolled steel, the phosphate layer of $60{\AA}$ thickness was found to act as a protective film over the relatively thin Fe oxide layer.

  • PDF

Correlation between Corrosion Rate and Red Water on Application of Corrosion Inhibitor in Drinking Water Distribution System (배급수 계통에서 부식억제제 적용에 따른 부식과 적수와의 상관관계)

  • Woo, Dal-Sik;Ku, Sung-Eun;Lee, Byung-Doo;Kim, Ju-Hwan;Moon, Kwang-Soon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.68-77
    • /
    • 2005
  • This study was performed to evaluate the application of corrosion inhibitor and to examine the correlation between corrosion rate and red water in a series of batch tests and a test using auto corrosion monitoring system at A water treatment plant in Gyeonggido. The corrosion study in the auto corrosion monitoring system indicated that Fe concentration decreased by 30~50% and corrosion rate also reduced remarkably with corrosion inhibitor at $1.8mg\;PO_4/L$. After addition of corrosion inhibitor, it was indicated the effective adsorption of the inhibitor on the surface of the pipe line forming a protective film. The corrosion rate increases with the increase in Fe concentration. With $1.8mg\;PO_4/L$ of corrosion inhibitor, the corrosion rate decreased remarkably. Fe concentration had correlation to not only red water problems but also the corrosion rate that actually dissolved into the water, primarily due to the deposition of oxidized iron or other compounds as a scale, which serves as a large reservoir of corrosion by-product. Therefore, corrosion rate can be estimated by Fe concentration. For these reasons, an effective corrosion inhibitor is also an effective red water control reagent. The effect of the corrosion inhibition can last for some time even the application the corrosion inhibitor is discontinued. For the cost effective and efficient corrosion control, the concentration and timing of corrosion inhibitor addition must be determined properly.

The Analysis of the Discharging Characteristics and MgO protective layer by MgO Evaporation Rates for High-Efficiency PDP (MgO 증착률에 따른 PDP 보호막 물성 및 방전 특성 분석)

  • Kim, Yong-Jae;Kwon, Sang-Jik
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.3
    • /
    • pp.181-186
    • /
    • 2007
  • We have investigated and analyzed the effects of the evaporation rate of MgO films on the MgO properties and the discharge characteristics of a plasma display panel(PDP). The MgO properties such as the crystal orientation, the surface roughness, the film structure, and cathode-luminescence (CL) spectra were inspected using XRD (X-ray diffraction), AFM(atomic force microscopy). And the discharging characteristics of the PDP such as the firing voltage, discharging current, and luminescence were measured using a vacuum chamber with oscilloscope (TDS 540C), current probe (TCP-312A), color meter (CS-100A) and etc. From the experiments results we confirmed the optimum evaporation rate at $5{\AA}/sec$, the MgO properties were shown to be strongly dependent on the evaporation rate, and the MgO properties had an effecton the optical and electrical characteristics. In other words, if the evaporation rates increase than $5{\AA}/sec$, the intensity of (200) orientation and cathode-luminescence (CL) spectra reduce, and the firing vlotage was increased. So the luminuous efficiency grows worse.

Effect of Mo and Mn Addition on the Oxidation Behavior of Binary Ti-Al Alloys

  • Han, Chang-Suk;Jin, Sung-Yooun;Bang, Hyo-In
    • Korean Journal of Materials Research
    • /
    • v.28 no.6
    • /
    • pp.361-364
    • /
    • 2018
  • Binary Ti-Al alloys below 51.0 mass%Al content exhibit a breakaway, transferring from parabolic to linear rate law. The second $Al_2O_3$ layer might have some protectiveness before breakaway. Ti-63.1 mass%Al oxidized at 1173 K under parabolic law. Breakaway oxidation is observed in every alloy, except for Ti-63.1 mass%Al. After breakaway, oxidation rates of the binary TiAl alloys below 34.5 mass%Al obey almost linear kinetics. The corrosion rate of Ti-63.1 mass%Al appears to be almost parabolic. As content greater than 63.0 mass% is found to be necessary to form a protective alumina film. Addition of Mo improves the oxidation resistance dramatically. No breakaway is observed at 1123 K, and breakaway is delayed by Mo addition at 1173 K. At 1123 K, no breakaway, but a parabolic increase in mass gain, are observed in the Mo-added TiAl alloys. The binary Ti-34.5 mass%Al exhibits a transfer from parabolic to linear kinetics. At 1173 K, the binary alloys show vary fast linear oxidation and even the Mo-added alloys exhibit breakaway oxidation. The 2.0 mass%Mo-added TiAl exhibits a slope between linear and parabolic. At values of 4.0 and 6.0 mass% added TiAl alloys, slightly larger rates are observed than those for the parabolic rate law, even after breakaway. On those alloys, the second $Al_2O_3$ layer appears to be persistently continuous. Oxidation resistance is considerably degraded by the addition of Mn. Mn appears to have the effect of breaking the continuity of the second $Al_2O_3$ layer.

Hot Corrosion Behavior of Al-Y Coated Haynes 263 in Lithium Molten Salt under Oxidation Atmosphere (리튬용융염계 산화성분위기에서 Al-Y 코팅한 Haynes 263의 고온 부식거동)

  • Cho Soo-Hang;Lim Jong-Ho;Chung Jun-Ho;Seo Chung-Seok;Park Seoung-Won
    • Korean Journal of Materials Research
    • /
    • v.15 no.3
    • /
    • pp.155-160
    • /
    • 2005
  • The electrolytic reduction of spent oxide fuel involves the liberation of oxygen in a molten LiCl electrolyte, which results in a chemically aggressive environment that is very corrosive fir typical structural materials. So, it is essential to choose the optimum material f3r the process equipment handling molten salt. In this study, the corrosion behavior of Al-Y coated Haynes 263 in a molten salt of $LiCl-Li_2O$ under oxidation atmosphere was investigated at $650^{\circ}C$ for $72\~168$ hours. The corrosion rate of Al-Y coated Haynes 263 was low while that of bare Haynes 263 was high in a molten salt of $LiCl-Li_2O$. Al-Y coated Haynes 263 improved the corrosion resistance better than bare Haynes 263 alloy. An Al oxide layer acts as a protective film which Prohibits Penetration of oxygen. Corrosion Products were formed $Li(Ni,Co)O_2$ and $LiTiO_2$ on bare Haynes 263, but $LiAlO_2,\;Li_5Fe_5O_8\;and\;LiTiO_2$ on Al-Y coated Haynes 263.

Comparison of Standardized Peristomal Skin Care and Crusting Technique in Prevention of Peristomal Skin Problems in Ostomy Patients

  • Park, Seung-Mi;Lee, Yun-Jin;Oh, Doo-Nam;Kim, Ji-Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.6
    • /
    • pp.814-820
    • /
    • 2011
  • Purpose: This study was performed to compare the effects of standardized peristomal skin care (SPSC) and crusting technique (CT) on the peristomal skin of ostomates. SPSC was developed by a consensus among the expert group based on a comprehensive review of the relevant literature and hospital protocols. Methods: A randomized controlled pilot trial with 2 parallel arms was used. A total of 81 ostomates, who were recruited from a tertiary hospital, completed the baseline, 1-month, 2-month, and 3-month follow-up (SPSC group, n=45; CT group, n=36). SPSC consisted of water cleansing and direct application of ostomy appliances. CT involved crusting hydrocolloid powder and patting with water sponge or protective barrier liquid film. The outcomes of the study were assessed by skin problems, such as discoloration, erosion and tissue overgrowth; the domains of the evaluation tool used in examining the peristomal skin. A generalized estimating equation model was used to examine the effects according to time and group. Results: In both SPSC and CT groups, the likelihood of occurrence of discoloration (OR, 1.99; 95% CI, 1.61-2.46), erosion (OR, 1.87; 95% CI, 1.55-2.25) and tissue enlargement (OR, 1.94; 95% CI, 1.36-2.77) increased with time. There was no significant difference in discoloration between the groups, whereas the probability of erosion (OR, 0.38; 95% CI, 0.16-0.89) and tissue overgrowth (OR, 0.09; 95% CI, 0.02-0.55) was lower in the SPSC group than in CT group. Conclusion: SPSC was sufficient in preventing peristomal skin problems of ostomates compared to the CT.

How Does the Movie Affect Child Actors (Actresses) on Piaget's Cognitive Developmental Theory? (피아제의 인지발달학적 측면에서 영화가 아동 배우에게 어떠한 영향을 미치는가?)

  • Kim, Bongseog;Park, Jiung;Hwang, Jun-Won;Yoo, Hee-Jeong;Kwack, Young-Sook;Bahn, Geon Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.24 no.2
    • /
    • pp.65-70
    • /
    • 2013
  • Many child actors have appeared in various movies as the Korean film industry continues to evolve. As more children appear in violent and raunchy scenes, there are more concerns about the movie's effect on child actors. In some Western countries, many strategies have been developed for child actors, but for the Korean movie industry, the conditions are still poor for them. Although children who enter the concrete operational period are able to think logically and systematically, they are yet limited by their experiences. Adolescents in the formal operational period try to deal with all of the possibilities and assumptions logically and systematically with freedom from realistic contents and experiences. This period is very important because adolescents become more sensitive to others' feelings and they should develop their ego identity. Several studies have reported the indirect experiences through media including how the movie affected children and adolescents negatively. Depending on the individual's morality, judgment and emotional status, these effects were variable and inconsistent and could be relieved by several interventions. We could anticipate much bigger emotional effect on child actors who are acting directly and then are confronting themselves in the scene. Therefore, we suggest that the emotional effects of the movies on child actors can be managed properly by considering children's cognitive ability and emotional status, and establishing protective strategies before they are exposed to problematic scenes. Of course, it should be followed by evaluating them after the exposure and with follow-up management, if necessary.

The Study of Corrosion Behavior for Solution and Aging Heat Treated Ti alloy (Ti 합금의 용체화열처리와 시효열처리에 따른 부식거동)

  • Baik, Shin-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.138-144
    • /
    • 2016
  • Titanium is resistant to general corrosion and in sea water because of the passivity layer film on the surface of material, but may be attacked by environments that cause breakdown of the protective oxide layer including hydrochloric, sulfuric and phosphoric acids. In this study, the Ti alloys were solution heat treatment 5hours at $1066^{\circ}C$ and $966^{\circ}C$, and followed by aging heat treated, 1, 4, 8 and 16 hours in $500^{\circ}C$, $600^{\circ}C$ and $650^{\circ}C$ respectively. The heat treated specimens were measured micro Vicker's hardness, and then accomplished electrochemical polarization test for comparing corrosion in 1N sulfuric acid solution. Additionally, micro structures were taken for corrosion tested specimens. The results showed that corrosion resistance was higher in solution heat treated alloy than base and age heat treated metal. Measured corrosion resistants were increased as increasing aging heat treatment time and temperature.

Effect of Sulfuric Acid Addition on the Aluminum AC Etching in HCl Solution (염산용액내에 황산 첨가에 의한 알루미늄의 교류에칭 특성)

  • Kim, Hangyoung;Choi, Jinsub;Tak, Yongsug
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.463-468
    • /
    • 1998
  • When sulfuric acid was added in HCl etching solution, corrosion of aluminum metal was inhibited by the chemical adsorption of sulfate ions. In the presence of $SO_4^{-2}$, cyclic voltammetry showed that the protective oxide film was formed on the inner surfaces of etch pits and, pit density was increased by nucleation on both the aluminum surface and the pits inside. Structure and distribution of etch pits found in AC etching of aluminum were strongly influenced by the concentration of $SO_4^{-2}$ and the amount of cathodic pulse charging. Below $0.8mC/cm^2$ of cathodic pulse charging, oxide films formed inside actively dissolving pits indicated the higher resistance to pit nucleation as the concentration of $SO_4^{-2}$ increases. However, the structural change of oxide films occurred above the $0.8mC/cm^2$ charging and the effect of $SO_4^{-2}$ was minimized, and it resulted in the rapid formation of etch pits.

  • PDF

Evaluation of the Characteristics of the Aluminum Alloy Casting Material by Heat Treatment (AC8A 알루미늄합금 주조재의 열처리에 의한 특성 평가)

  • Lee, Syung Yul;Park, Dong Hyun;Won, Jong Pil;Kim, Yun Hae;Lee, Myung Hoon;Moon, Kyung Man;Jeong, Jae Hyun
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.280-285
    • /
    • 2012
  • Aluminum is on active metal, but it is well known that its oxide film plays a role as protective barrier which is comparatively stable in air and neutral aqueous solution. Thus, aluminum alloys have been widely applied in architectural trim, cold & hot-water storage vessels and piping etc., furthermore, the aluminum alloy of AC8A have been widely used in mold casting material of engine piston because of its properties of temperature and wear resistance. In recent years, the oil price is getting higher and higher, thus the using of low quality oil has been significantly increased in engines of ship and vehicle. Therefore it is considered that evaluation of corrosion resistance as well as wear resistance of AC8A material is also important to improve its property and prolong its lifetime. In this study, the effect of solution and tempering heat treatment to corrosion and wear resistance is investigated with electrochemical method and measurement of hardness. The hardness decreased with solution heat treatment compared to mold casting condition, but its value increased with tempering heat treatment and exhibited the highest value of hardness with tempering heat treatment temperature at $190^{\circ}C$ for 24hrs. Furthermore, corrosion resistance increased with decreasing of the hardness, and decreased with increasing of the hardness reversely. As a result, it is suggested that the optimum heat treatment to improve both corrosion and wear resistance is tempering heat treatment temperature at $190^{\circ}C$ for 16hrs.