• 제목/요약/키워드: protection of structure

검색결과 1,276건 처리시간 0.028초

The effect of cathodic protection system by means of zinc sacrificial anode on pier in Korea

  • Jeong, Jin-A;Jin, Chung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1206-1211
    • /
    • 2014
  • This study has been conducted to confirm the effect of sacrificial anode cathodic protection system for 90 days to protect corrosion on pier that is located in Korea. The cathodically protected structure was a slab and a pile cap. Before the construction of cathodic protection system, the macrography was carried out. As a result of the macrography, many corrosion traces were confirmed in this structure. The trace was mainly focused on joint and zones that concrete cover was eliminated. To apply the cathodic protection system, many onsite techniques have been adopted. In addition, to confirm the inner state of steel in concrete properly, a corrosion monitoring sensor (DMS-100, Conclinic Co. Ltd) has been applied. Test factors were corrosion & cathodic protection potential, 4 hour depolarization potential, resistivity and current density. After 90 days from the installation of cathodic protection system, it could confirm that proper corrosion protection effect was obtained by considering the result of tests.

스텍 구조를 이용한 향상된 스냅백 특성을 갖는 ESD 보호회로 설계 (Design of ESD Protection Circuit with improved Snapback characteristics Using Stack Structure)

  • 송보배;이재학;김병수;김동순;황태호
    • 전기전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.280-284
    • /
    • 2021
  • 본 논문에서는 스냅백 특성을 개선시키기 위해 일반적인 SCR의 구조적 변경 및 Stack 기술을 적용한 새로운 구조의 ESD 보호회로를 제안한다. 펜타-웰과 더블 트리거를 이용한 구조에 대한 전기적 특성을 분석하고 Stack 구조를 적용해 트리거 전압과 홀딩 전압을 개선하였다. 시뮬레이션을 통한 전자 전류와 총 전류 흐름을 분석 하였다. 이를 통해 레치-업 면역 특성과 우수한 홀딩전압 특성을 확인 하였다. 제안된 ESD 보호회로의 전기적 특성은 TCAD 시뮬레이터를 통해 구조를 형성하고 HBM 모델링을 통해 분석 하였다.

Structure Optimization of ESD Diodes for Input Protection of CMOS RF ICs

  • Choi, Jin-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권3호
    • /
    • pp.401-410
    • /
    • 2017
  • In this work, we show that the excessive lattice heating problem due to parasitic pnp transistor action in the diode electrostatic discharge (ESD) protection device in the diode input protection circuit, which is favorably used in CMOS RF ICs, can be solved by adopting a symmetrical cathode structure. To explain how the recipe works, we construct an equivalent circuit for input human-body model (HBM) test environment of a CMOS chip equipped with the diode protection circuit, and execute mixed-mode transient simulations utilizing a 2-dimensional device simulator. We attempt an in-depth comparison study by varying device structures to suggest valuable design guidelines in designing the protection diodes connected to the $V_{DD}$ and $V_{SS}$ buses. Even though this work is based on mixed-mode simulations utilizing device and circuit simulators, the analysis given in this work clearly explain the mechanism involved, which cannot be done by measurements.

수공구조물이 하천환경에 미치는 영향에 관한 연구(II) : 수질 및 생태학적특성 (A Study on Effects of Hydraulic Structure on River Environment(II) : Water Quality and Ecological Characteristics)

  • 안승섭;최윤영;이수식
    • 한국환경과학회지
    • /
    • 제11권4호
    • /
    • pp.309-317
    • /
    • 2002
  • In this study, water protection reservoir is selected as the target which is located at the estuary of Taehwa river to analyze and examine the effects of hydraulic structure on river environment. This study examined the water quality variation characteristics among many effects of hydraulic structure on river environment before and after removal of the sediment protection reservoir when low flow is yielded. This study aims at the definition of factors which cause the change of ecological environment of river due to the effects of the sediment protection reservoir, and the proposal of the direction of environmental friendly river space development through the comparison of stream variation conditions(depth, velocity, and etc.) and riverbed variation characteristics with ecological depth condition of Taehwa-river's channel for each representative species of fish and examination those. Firstly, from the examination result of water quality when low flow is yielded before and after removal of the sediment protection reservoir for problems about water quality of river due to flow amount decrease in river, it is found that DO decreases about 0.78~0.86ppm at the lower stream of Myeongchon-gyo, and BOD decreases about 0.06~0.24ppm from right upper stream to the direction of estuary when the sediment protection reservoir is removed. It is known from the above that there is some improvement of water quality from the lower stream of Taehwa-gyo to the estuary in case of removal the sediment protection reservoir. Nextly, it is thought that the effects on ecosystem due to water depth and draw down in channel is not serious on the basis of the examination of water quality analysis result according to removal of sediment protection reservoir and hydraulic depths for reservation of ecosystem, these are 10~40cm for breeding season, 10~50cm for fry period, and 10~100cm for adult period of the representative species of fish in Korea.

Development of a structure analytic hierarchy approach for the evaluation of the physical protection system effectiveness

  • Zou, Bowen;Wang, Wenlin;Liu, Jian;Yan, Zhenyu;Liu, Gaojun;Wang, Jun;Wei, Guanxiang
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1661-1668
    • /
    • 2020
  • A physical protection system (PPS) is used for the protection of critical facilities. This paper proposes a structure analytic hierarchy approach (SAHA) for the hierarchical evaluation of the PPS effectiveness in critical infrastructure. SAHA is based on the traditional analysis methods "estimate of adversary sequence interruption, EASI". A community algorithm is used in the building of the SAHA model. SAHA is applied to cluster the associated protection elements for the topological design of complicated PPS with graphical vertexes equivalent to protection elements.

피뢰설비현장의 접지 및 전기적 연속성 시험에 따른 표준적용 (The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field)

  • 송길목;구경완
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.583-588
    • /
    • 2014
  • In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.

3D 프린팅 기술을 활용한 낙상충격 보호패드 구조설계 및 필라멘트 소재에 따른 특성 비교 (Structure Design of Fall Impact Protection Pad Using 3D Printing Technology and Comparison of Characteristics According to Filament Material)

  • 박정현;정희경;이정란
    • 한국의류학회지
    • /
    • 제41권5호
    • /
    • pp.939-949
    • /
    • 2017
  • This study uses 3D printing technology to design and fabricate a fall impact protection pad with a spacer fabric structure. The design of the pads consists of hexagonal three-dimensional units connected in a honey-comb shape; in addition, the unit consists of a surface layer and a spacer layer. Protect pads were designed as either a hexagonal type or diamond type according to the surface layer structure; subsequently, a spacer filament was also designed as the most basic I-shape type. Designed pads were printed using four types of flexible filaments to select suitable material for a fall impact protection pad. Impact protection performance and bending stiffness were evaluated for the eight type of pad outputs. As a result of the impact protection performance evaluation, when the force of 6,500N was applied, the force passed through the pad was in the range of 1,370-2,132N. FlexSolid$^{(R)}$ and Skinflex$^{TM}$ showed good protection performance and cubicon flexible filament showed the lowest protection. NinjaFlex$^{(R)}$ was found to be the most flexible in the bending stiffness evaluation.

RHEOLOGICAL STUDY ON STRAINER STRUCTURE OF UNDER DRAIN PIPES FOR SLOPE PROTECTION

  • Mihara. Machito;Yasutomi, Rokuro;Nakamura, Yoshio
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.197-204
    • /
    • 1993
  • Pipe drainage is one of the effective slope protein works that can be adopted practically. As fine soil particles are suspended in percolating water, the strainer structure of under drain pipes in necessary to prevent the immediate clogging by soil suspension flow. This study deals with the effective strainer structure of under drain pipes for slope protection. The effective strainer structure of under pipes is the funneled strainer in which pore radius is enlarged toward flow direction. It is designed from the rheological properties of soil suspension flow which prevents the immediate clogging. Experimental results showed that the pipe drain discharge through the funneled strainers was larger than that through the constant pore radius strainers. This theorectial and experimental results indicate that the strainer with enlarged pore radius toward flow direction, is more effective than the strainer with constant pore radius.

  • PDF

생태계제어 구조물의 파랑제어 효과에 관한 연구 (A study on the wave control function of ecosystem control structures)

  • 김현주;류청로;손원식
    • 한국해양공학회지
    • /
    • 제10권4호
    • /
    • pp.149-159
    • /
    • 1996
  • Multipurpose development of the coast and ocean can be considered as multifunction construction combining the functions of coastal protection, waterfront amenity and creation or rehabilitation of habitats. Multfunction development of coastal and ocean spaces can be accomplished by applying the ecosystem control structure of artificial habitats which will cultivate fishing ground with ecological harmony to the coastal protection system. To evaluate the applicability of ecosystem control structures as as fundamental coastal protection structure, wave control function of the structure is studied by numerical and physical analyses. Dimensional analysis and hydraulic experiment point out the importance of width and crest depth of ecosystem control structure, construction water depth and wave steepness. Wave control efficiency is estimated by the attenuation coefficient $(K_H)$ according to wave steepness $(H_0/L_0)$, relative constructed water depth $(h_i/H_0)$, relative berm width $(B/L_0)$ and relative crest depth $(h_B/H_0)$ of eosystem control structure. Empirical fomulas are suggested based on the results of model test by applying the multiple model based on this experimental results and numerical wave shoaling-dissipation-breaking model appears to be valid for the analysis of wave transformation around ecosystem control structure in the coastal waters.

  • PDF

차량 COWL구조에 따른 보행자 머리 상해치 영향에 관한 연구 (A study on effect of pedestrian head injury with vehicle cowl structure type)

  • 홍규갑;정호영;조원철;이태식
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.517-519
    • /
    • 2008
  • 2007, Pedestrian protection test is operated by Korea ministry of construction & transportation. This paper focused on small size vehicle cowl structure type for reducing pedestrian head injury.

  • PDF