The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field  

Song, Gil-Mok (Korea Electrical Safety Corporation-YEOSU)
Koo, Kyung-Wan (Dept. of Defence Science and Technology, Hoseo University)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.63, no.4, 2014 , pp. 583-588 More about this Journal
Abstract
In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.
Keywords
Electrical continuity testing; Lightning protection; Ground; rolling sphere method; Field application standard;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Ju-Cheol Lee, etal., "Recent trends in international standards for electrical installations and lightning protection", 2013 KIIEE fall conf., pp.116-117, 2013.
2 NFPA, "NFPA 780 - Standard for the Installaion of Lightning Protection System", 2008.
3 IEC 62305-1, "Protection against lightning - Part 1: General principles", IEC T.C.81, 2010.
4 V. A. Rakov & M. A. Uman, "Lightning: Physics and Effects", Cambridge Univ. Press, 2003.
5 Sung-Chul Cho, etal., "Verification structure for performance evaluation of spatial shielding in lightning protection zone(LPZ)", 2013 KIEE summer conf., pp.1354-1355, 2013.
6 Myeong-Il Choi, etal., "The survey analysis and case studies for diagnostic of lightning protection system", 2010 KIEE fall conf., pp.227-228, 2010.
7 Chun-Yong An, etal., "Lightning overvoltage analyss according to interval of arrester and overhead grounding wire in DC distribution system", The Trans. of the KIEE, Vol. 62, No. 4, pp.474-481, 2013.
8 P. Y. Okyere, etal., "Evaluation of rolling sphere method using leader potential concept: A case study", Proc. of the 2006 IJME-INTERTECH Conf., pp.1-20, 2006.
9 Myeong-Il Choi, etal., "A study on analysis system of three-dimensional structures for diagnosis of lightning protection facilities", 2010 KIEE spring conf., pp.164-166, 2010.