• Title/Summary/Keyword: proof procedure

Search Result 60, Processing Time 0.029 seconds

소형 장기체공형 무인기 날개의 구조 개량 설계

  • Lee, Jung-Jin
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.179-185
    • /
    • 2002
  • In this study, the structural design method for the modified long-endurance UAV is presented. Composite materials using room temperature curing method and wet lay up procedure is applied to all wing structures. The modified wing is composed of 3-piece component for improvement of ground handling. As the sandwich structure is efficient for light weight and high stiffness, all skin is used the sandwich consisting of glass/ epoxy fabric and balsa wood. The proof test is performed up to limit load corresponding to 4g load condition for the modified wing structure.

  • PDF

THE EXTENSION OF SOLUTIONS FOR THE CAUCHY PROBLEM IN THE COMPLEX DOMAIN II

  • Lee, Eun-Gu;Kim, Dohan
    • Bulletin of the Korean Mathematical Society
    • /
    • v.30 no.1
    • /
    • pp.29-34
    • /
    • 1993
  • J. Leray [7] proposed a sufficient condition ofr the solvability of the Cauchy problem on the initial hyperplane x$_{1}$=0 with Cauchy data which are holomorphic with respect to the variables parallel to some analytic subvariety S of the initial hyperplane. Limiting the problem to the case of operators with constant coefficients, A. Kaneko [2] proposed a new sharper sufficient condition. Later we generalized this condition and showed that it is necessary and sufficient for the solvability of the Cauchy problem for the hyperfunction Cauchy data and the distribution Cauchy data which contain variables parallel to S as holomorphic parameters in [5, 6]. In this paper, we extend the results in [6] to the case of operators with variable coefficients and show that it is sufficient for the solvability of the Cauchy problem for the hyperfunction Cauchy data. Our main theorem can be considered as an example of a deep theorem on micro-hyperbolic systems by Kashiwara-Schapira [4] and we give a direct proof based on an elementary sweeping out procedure developed in Kaneko [3].

  • PDF

A New Weighted Synaptic Connectvity Matrik for Component Retrieval (컴포넌트 검색을 위한 새로운 가중치 신경 접속 행렬)

  • 금영욱
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Component-based software development(CBSD) is gaining popularity Effective search and retrieval of desired components, which are stored in a component repository, is a very important issue in CBSD. In this paper. a new weighted synaptic connectivity matrix is proposed to find more appropriate components. An algorithm is proposed for effective search with NOT operator and a proof for the algorithm is Presented . A new procedure to calculate the output vector for a logically combined query is also presented.

  • PDF

Regarding Issues on the Lawsuit of Medical Malpractice in the Implant Procedure -Focusing on the contract's legal character and the mitigation of burden of proof- (임플란트 시술상 의료과오의 소송상 쟁점에 관하여 -계약의 법적성격 및 입증책임 완화를 중심으로-)

  • Han, Taeil
    • The Korean Society of Law and Medicine
    • /
    • v.19 no.1
    • /
    • pp.143-163
    • /
    • 2018
  • Implant procedure belongs to so called a commercialized medical treatment, its procedure is simple and clear, and the possibility of success is almost 100%. In addition, it is a selective method rather than an inevitable method for a patient's health, so the importance of liability for explanation is especially emphasized for protection of autonomous decisions by patients. Considering these characteristics, the plaintiff in the relevant case said that the contract of implant procedure has the characteristic of subcontract, and only the failure of implant itself and the violation of liability for explanation should be the defendant's fault liability. In addition, although the above procedure contract is considered as delegation rather than subcontract, whether it's the defendant's malpractice should be judged by general people's common sense rather than average people in the industry. Therefore, if all the implanted teeth were removed due to bleeding and pains, and the patient suffered from dysaesthesia during the process, the defendant's malpractice is fully proved. When the judgements of implant medical malpractice were researched, the court doesn't consider implant contract as subcontract, but it judges dentist's malpractice by whether the implant itself is successful, so it seems that the court acknowledges similar characteristics with subcontract whose purpose is completion of work to some degree. In addition, considering the detailed contents of presented medical malpractices, it seems that judging medical malpractice is based on the common sense of general people. Therefore, the argument of the plaintiff is valid when the fact the adjustment amount is relevant to the amount that the plaintiff initially claimed is considered even though the relevant case was decided to be compulsory mediation.

Problems and Developing Directions of the Legal System Related to Laboratory medical testing (검체검사 관련 법제도의 문제점 및 발전방향)

  • Hwang, Yoo-Sung;Jeong, Jeong-Ile
    • The Korean Society of Law and Medicine
    • /
    • v.9 no.2
    • /
    • pp.209-229
    • /
    • 2008
  • When we are totalizing the lawsrelated to the medical, as the Laboratory medical testing is a kind of the medical act, it is the regulation that the medical technologist can analyze the specimen using in vitro diagnostic devices and diagnosticdrugs under the guidance of doctor or dentist from a corresponding medical institution and can report through verification and interpretation. However, in real medical fields, 'the guidance of doctor' is seriously in-sufficient or even the person who is not the medical technologist is executing. Furthermore the cases that produce inspection results with devices or reagents which are not validated nor approved have been frequently occurred. The result of Laboratory medical testing derived from this procedure can become the important information for the disease control of a country, and also can be decisive to the definite diagnosis and the prognostic monitoring about the patient disease. In spite of its significant medical act to be applicable to an unique proof with the related expert appraisal result in the medical mal-practice lawsuit, our reality in which the quality control is not properly working due by the costs and the labor shortage related to the Laboratory medical testing is quietly in bad condition. Even from now, the government should recognize the significance of the Laboratory medical testing and must achieve more strict administrative management as well as the law maintenance.

  • PDF

A Comparative Study on bank's responsibilities in the Electronic Payment System -comparison between Korea and U.S.A- (국제 전자결제시스템에서 금융기관의 책임 및 정책적 시사점 -한국과 미국의 전자금융제도 비교-)

  • Lee, Byeong-Ryul
    • International Commerce and Information Review
    • /
    • v.12 no.1
    • /
    • pp.35-54
    • /
    • 2010
  • This article explored the bank's responsibilities in electronic payment system between Korea and U.S.A. In order to complete my research object, I used Article 4A of the U.C.C. and EFTA of 1978 and by Electronic Financial Transaction Act of Korea as a analytic instruments. I also adapted America's various regulations to regulate concerned parties(banks). The system of this article is going to display as fellows; First, I presented recent trend and legal stabilities of electronic payment in this article. Second, I focuses on the allocation of risk of loss caused by ambiguous term in payment orders that do not express the subjective intention of the senders. I also did analyze the solution procession of error occurring in course of send of payment order. Third, In any action which involves a customers's liability for an unauthorized electronic fund transfer, the burden of proof is upon the financial institution to show that the electronic fund transfer was authorized. Forth, Customers have to report the error and unauthorized electronic fund transfer after awaring of it. Then bank will be liable for such a unauthorized electronic fund transfer. But If customer's failure to report, the bank has exemptions. Lastly, In order to prevent or detect the unauthorized electronic fund transfer, bank will agree with custom to establish a commercially reasonable security procedure, while bank has duties to notify in order to decrease the loss resulted from unauthorized payment order in korea law.

  • PDF

Development of the Moisture Protected Computer - Efficiency Test of the MPC - (수분 밀폐형 컴퓨터시스템(MPC) 개발 - MPC의 성능평가 -)

  • Kim, Jin-Hyun;Kim, Tae-Wook;Sung, Kwang-Kee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.2
    • /
    • pp.115-122
    • /
    • 2007
  • The MPC(Moisture Protected Computer) system is completely unique. It was recently invented in Korea and it is a technological break-through in the field of computer systems. It will be instrumental in the development of a complete moisture air-tight capability and will work well in field environments. The MPC includes the following: 1) An enclosed design. 2) Moisture proof computer enclosure joints. 3) System dust protection & an impact buffing system. 4) A normal temperature maintenance system when the temperature inside the computer is low. 5) The ability to generate heat and a radiate system inside the computer 6) An automatic power input sensing controller device. 7) A safety device in case of mis-operation. 8) A proper admission procedure for various tests. Because of the above, and as a result of temperature property experiments, there aren't any operational problems. The result of this treatise could provide very important data for verification of cases involving: using strong materials to protect against explosions, searching for ways to make the size and weight small, and for making repairs easier. As a result, it could achieve price and function competitiveness in advanced countries such as the USA and in Europe.

  • PDF

Closed Queueing Networks and Zeros of Successive Derivatives

  • Namn, Su-Hyeon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.22 no.1
    • /
    • pp.101-121
    • /
    • 1997
  • Consider a Jackson type closed queueing network in which each queue has a single exponential server. Assume that N customers are moving among .kappa. queues. We propose a candidata procedure which yields a lower bound of the network throughput which is sharper than those which are currently available : Let (.rho.$_{1}$, ... .rho.$_{\kappa}$) be the loading vector, let x be a real number with 0 .leq. x .leq. N, and let y(x) denote that y is a function of x and be the unique positive solution of the equation. .sum.$_{i = 1}$$^{\kappa}$y(x) .rho.$_{i}$ (N - y(x) x $p_{i}$ ) = 1 Whitt [17] has shown that y(N) is a lower bound for the throughput. In this paper, we present evidence that y(N -1) is also a lower bound. In dosing so, we are led to formulate a rather general conjecture on 'quot;Migrating Critical Points'quot; (MCP). The .MCP. conjecture asserts that zeros of successive derivatives of certain rational functions migrate at an accelerating rate. We provide a proof of MCP in the polynomial case and some other special cases, including that in which the rational function has exactly two real poles and fewer than three real zeros.tion has exactly two real poles and fewer than three real zeros.

  • PDF

A Shock Damage Evaluation Study of Large Digital TV Display Modules (대형 디지털TV Display 모듈의 내충격 설계를 위한 손상평가 연구)

  • 문성인;최재붕;김영진;서형원;이정권;구자춘
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.10
    • /
    • pp.945-954
    • /
    • 2004
  • Recently, specifications of flat display module is going to be higher definition, brightness and more wide viewing angle. On the other hand, physical thickness of those modules is forced to be slimmer and lighter. The flat display modules such as plasma or TFT-LCD employ thin crystallized panels that are normally weak to high level transient mechanical energy inputs. As a result, anti-shock performance is one of the most important design specifications of TFT-LCD modules. TFT-LCD module manufacturers and their customers like PC or TV makers perform a series of strict impact/drop test for the modules. However most of the large display module designs are generated based on engineer's own trial-error experiences. Those designs may result in disqualification from the drop/impact test during final product evaluation. A rigorous study on the impact failure of the displays is of course necessitated in order to avoid the problems. In this article, a systematic design evaluation is presented with combinations of FEM modeling and testing to support the optimal shock proof display design procedure.

Study on The Anti-Shock Performance Evaluation of TFT-LCD module for Mobile IT Devices (이동형 정보통신 기기용 화면표시 장치의 내충격 평가 방법 연구)

  • Kim Byung-Sun;Kim Jung-Woo;Lee Dock-Jin;Choi Jae-Boong;Kim Young-Jin;Baik Seung-Hyun;Chu Young-Bee;Koo Ja-Choon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.130-137
    • /
    • 2006
  • TFT-LCD(Thin Film Transistor Liquid Crystal Display) module is representative commercial product of FPD(Flat Panel Display). Thickness of TFT-LCD module is very thin. It is adopted for major display unit for IT devices such as Cellular Phone, Camcorder, Digital camera and etc. Due to the harsh user environment of mobile IT devices, it requires complicated structure and tight assembly. And user requirements for the mechanical functionalities of TFT-LCD module become more strict. However, TFT-LCD module is normally weak to high level transient mechanical shock. Since it uses thin crystallized panel. Therefore, anti-shock performance is classified as one of the most important design specifications. Traditionally, the product reliability against mechanical shock is confirmed by empirical method in the design-prototype-drop/impact test-redesign paradigm. The method is time-consuming and expensive process. It lacks scientific insight and quantitative evaluation. In this article, a systematic design evaluation of TFT-LCD module for mobile IT devices is presented with combinations of FEA and testing to support the optimal shock proof display design procedure.