• Title/Summary/Keyword: proceeding bearing

Search Result 2,015, Processing Time 0.031 seconds

Target Probability of Failure of Quay Wall Foundation for Reliability-Based Design (안벽기초 구조물의 신뢰성설계를 위한 목표파괴확률 결정)

  • Yoon, Gil-Lim;Yoon, Yeo-Won;Kim, Hong-Yeon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.379-389
    • /
    • 2010
  • It is very important to determine a target probability of failure in reliability based design such as an allowable factor of safety in working stress design because they are indices to judge the stability of structures. We have carried out reliability analyses of nationwide gravity type quay walls and found that sliding and foundation failures of quay walls were dominant failure modes for every case of loads. And a target probability of failure for bearing capacity of foundation of quay wall was also determined in this study. Of several approaches which have been suggested until now, a couple of reasonable approaches were used. Firstly, in order to consider the safety margin of structures which have been executed so far, the reliability levels of existing structures were assessed. And then a mean probability of failure for the quay walls was estimated. In addition, life cycle cost(LCC) analyses for representative structures were performed. Probabilities of failure for several quay walls were calculated with changing the width of each quay wall section. LCC of quay wall which is requiring case by case during the service life was evaluated, and also the optimum probability of failure of quay wall which minimizes LCC was found. Finally, reasonable target probabilities of failure were suggested by comparing with mean probability of failure of existing structures.

  • PDF

Determination of Resistance Factors for Drilled Shaft Based on Load Test (현장타설말뚝의 주면지지력 저항계수 산정)

  • Kim, Seok-Jung;Jung, Sung-Jun;Kwon, Oh-Sung;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.427-434
    • /
    • 2010
  • Load Resistance Factor Design method is used increasingly in geotechnical design world widely and resistance factors for drilled shafts are suggested by AASHTO. However, these resistance factors are determined for intact rock conditions, by comparison most of bedrocks in Korea are weathered condition, so that applying the AASHTO resistance factors is not reasonable. Thus, this study suggests the proper resistance factors for design of drilled shaft in Korea. The 22 cases of pile load test data from 8 sites were chosen and reliability-based approach is used to analyze the data. Reliability analysis was performed by First Order Second Moment Method (FOSM) applying 4 bearing capacity equations. As a result, when the Factor of Safety(FOS) were selected as 3.0, the target reliability index($\beta_c$) were evaluated about 2.01~2.30. Resistance factors and load factors are determined from optimization based on above results. The resistance factors ranged between 0.48 and 0.56 and load factor for dead load and live load are evaluated approximately 1.25 and 1.75 respectively. However, when the target reliability are considered as 3.0, the resistance factors are evaluated as approximately 50% of results when the target reliability index were 2.0.

  • PDF

An Experimental Study on the Characteristics of Seismic Isolators under Extreme Conditions (교량 지진격리받침의 극한특성에 대한 실험적 고찰)

  • Kwahk, Im-Jong;Yoon, Hye-Jin;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.105-108
    • /
    • 2008
  • For the early seismic isolation design in Korea, foreign products of isolation bearings were used. But these days, the application of domestic products of isolation bearings is increasing. However various experimental studies can be found very seldom on the extreme and lonr term behaviors of isolation bearings. In this study, we considered the laminated rubber type isolation bearings that have many application cases in Korea and we evaluated their shear strength, long term characteristics such as aging and creep affecting shear strength of bearings in long term period. For the reality of experiments, fabricated isolation bearing specimens are designed for a real structure and shear loading was applied under design compressive loads. To evaluated aging effect, the specimens were exposed to high temperature environment for certain period and their shear properties were measured to compare with their original values. Also we measured creep amount of isolation bearings under constant compressive load for 1,000 hours and estimated creep amount after 60 years compatible with general life cycle of bridges.

  • PDF

Strength of Compression Lap Splice in Confined Concrete (횡구속된 콘크리트에서 압축이음강도)

  • Chun, Sung-Chul;Lee, Sung-Ho;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.855-858
    • /
    • 2008
  • A compression lap splice can be calculated longer than a tension lap splice in high strength concrete according to current design codes. Including effects of transverse reinforcement, a compression splice becomes much longer than a tension splice. Effects of transverse reinforcement on strength and behavior of compression lap splice, which always exist in actual structures, have been investigated through experimental study of column tests with concrete strength of 40 and 60 MPa. Confined specimens have twice of calculated strengths by current design codes. New design equations for the compression lap splice including the effects of transverse reinforcement are required for practical purpose of ultra-high strength concrete. End bearing is enhanced by transverse reinforcement placed at ends of splice not by transverse reinforcement within splice length. As more transverse reinforcement are placed, the stresses developed by bond linearly increase. The transverse reinforcements at ends of splice a little improve the strength by bond.

  • PDF

A Ultimate Shear Performance of Elastomeric Bearings (탄성받침의 극한전단성능)

  • Yoon, Hye-Jin;Kwahk, Im-Jong;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.117-120
    • /
    • 2008
  • The bridge bearings are devices absorbing the displacements of the superstructure. KS F 4420 relative to the design of elastomeric bearings in Korea allows shear deformation up to 70% of total rubber height. For the elastomeric bearings to fulfill their shear function required in the design, the stability of allowable shear strain of elastomeric bearings relative to the shear failure should be guaranteed. Moreover considering the possibility that elastomeric bearings are applied to the seismic design together with isolation devices, elastomeric bearings is supposed to display higher shear performance. In this paper ultimate shear performance tests were performed. The measured ultimate shear strains were over 200%. Therefore an allowable shear strain provision becomes safe. But elastomeric bearings expected to show their performance in one united body reveled the separation of components near 200% shear strain. These separation in elastomeric bearing can cause unexpected impact or concentrated stress to bridge system considering to application of seismic design. Therefore provision relevant to separation problem is necessary.

  • PDF

An Experimental Study on Compressive Loading Capacity of PCT System (PCT System의 압축내하력에 관한 실험적 연구)

  • Han, Man-Yup;Kim, Jae-Hong;Kang, Sang-Hun;Jin, Kyung-Seok;Jeon, Yong-Sik;Cho, Byung-Ku
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.41-44
    • /
    • 2008
  • The PCT that supports the walls of long span temporary shoring facility is previously manufactured in the way of prestressing, and it which is composed of concrete is improved precast structure to satisfy enough stiffness. The components of PCT are manufactured as a fixed form, and they are close to the inner side of the wall of temporary shoring facility by fixed means in PCT. PCT system as support structure is that the ends of concrete filled segment members are united by the means of connection and also they have connection hole. In this study, PCT has enough bearing power for the long span temporary shoring facility, and also make the term of work reduce due to that the time of curing reduce through the method of precast.

  • PDF

Enhancing the Blast Resistance of Structures Using HPFRCC, Segmented Composites, and FRP Composites (HPFRCC, 분절 복합체 및 FRP를 활용한 구조물의 내폭 성능 향상)

  • Yoon, Young-Soo;Yang, Jun-Mo;Min, Kyung-Hwan;Shin, Hyun-Oh
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.745-748
    • /
    • 2008
  • The past structures were just required bearing capacity to service load, serviceability, and resistance to corrosion. However this point of view has changed after 9.11 terrorism, capacities which can bear impact loading by explosion, and heat by fire happening at the same time, become to be important as a basic condition. The blast resistance capacity of structures is very important part against all over the world is intimidated by terrorism everyday in current point of time. The target of this research is a development of segmented composites and layered structures with high blast resistance using cementitious composites, concrete and FRP composites, which has high tensile strength and ductility, to apply in not only existing facilities but also new ones. Through the improvement of blast resistance, casualties and economic loss can be minimized, and it is possible to diminish the structure collapse and delay the time of structure collapse by thermal effect, impact loading, dynamic loading and high strain.

  • PDF

Telecommunications Standardization Policy of Asia-Pacific Regional Standardization Organization (아ㆍ태 지역 표준화기구의 정보통신표준화 정책 고찰)

  • 김영태;박기식;박종봉
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.88-92
    • /
    • 2000
  • Since the launch of WTO. the global telecommunications market has been accelerated to ensure interoperability between the various telecommunications or services and this effort is emerging as the realization of an importance of standardization. In addition, in recent years as standardization is recognized not as just a means of ensuring interoperability but as a key strategic means of economic survival in the new trade order at the international regional, and national levels. Thus, each country is working actively to process telecommunications standardization through such means as multilateral cooperation and collective counter-strategies, which are mapped out, in the various regional and global fora and consortia. In keeping with these trends, Asia-Pacific Telecommunity, which is taking charge of telecommunications affairs of Asia-Pacific region, has been pursuing not only regional common interests but enhancement of its status in the world market by standardization on the basis of intimate collaboration, obtained by establishing regional standardization organization named ASTAP(APT Standardization Program). Bearing in mind the consideration outlined above, this paper aims to analyze telecommunications standardization policy intended by Asia-Pacific regional standardization organization and accordingly, to suggest a strategy for strengthening telecommunications standardization activities in Asia-Pacific region.

  • PDF

Two-Way Car Ferry Thrust Shaft Primary Support Part Structural Integrity Evaluation (양방향 카페리 추진축 1차 지지부 구조건전성 평가)

  • Kang, Byoung-Mo;Oh, Young-Cheol;Bae, Dong-Gyun;Ko, Jae-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.163-164
    • /
    • 2013
  • Two-Way CAR-FERRY land and islands, islands to islands, the connection between sustainable marine transportation in conjunction with the increasing demand of tourists, according to the associated coastal maritime tourism and passenger transport has a role. Subsequent Two-Way CAR-FERRY and the increased ease of use due to berthing maritime accidents can be reduced. Two-Way CAR-FERRY as the draft (even) in the state on both sides of the propeller, because the propeller due to the small diameter, low speed forward flight by the reaction at the shaft and propeller damage can occur. Engine output accordingly, linear and torsional vibration reducer by, elastic coupling selection transverse vibration and shaft alignment (Shaft alignment) considering the shaft design (bearing size, width, thickness) and the primary drive shaft support portion of the hull structure of evaluated for quality.

  • PDF

A Study on the Improvement Effects of Soft Ground through In-Situ Construction of NDS (NDS공법의 현장시험시공을 통한 지반개량 효과에 관한 연구)

  • Ahn, Joon-Hee;Park, Choon-Sik;Jang, Jeong-Wook;Kang, Hyoung-Nam;Kim, Yong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.653-657
    • /
    • 2005
  • This study applied the NDS method to the creek levee and the foundation of a building, for the purpose of ground improvement and cut-off. The conclusions are shown in the following. (1) The results of the field tests in the creek levee are as follows; the N value of the standard penetration test is $2{\sim}3$ before NDS grout and $9{\sim}21$ after NDS grout; in the alluvial layer, $7{\sim}11$ before NDS grout and $14{\sim}23$ after NDS grout. This confirms increasing ground strength with consistency ranging from stiff to very stiff. (2) The result of the permeability test in the creek levee shows that the ground had a great hydraulic conductivity with complete leakage before ground improvement but that the hydraulic conductivity has significantly increased to $3.17{\times}10^{-5}{\sim}4.65{\times}10^{-5}cm/sec$ after ground improvement by the NDS method. (3) The result from the field test of the foundation of the building confirms great reinforcing effects, showing that the allowable bearing capacity has increased from Pa = 5.0 $t/m^2$ before reinforcement to Pa = 25.0 $t/m^2$ after reinforcement.

  • PDF