• Title/Summary/Keyword: primary phase

Search Result 1,058, Processing Time 0.029 seconds

Quantitative Analysis of Lovastatin in Human Plasma and urine by Reversed-Phase High-Performance Liquid Chromatography (역상 고속액체크로마토그라프법을 이용한 혈장 및 뇨 중 로바스타틴의 정량)

  • Choi, Hye-Jin;Kim, Myoung-Min;Choi, Kyung-Eob
    • YAKHAK HOEJI
    • /
    • v.42 no.5
    • /
    • pp.473-479
    • /
    • 1998
  • Lovastatin (LOVA), a fungal metabolite isolated from cultures of Aspergillus terreus, is a competitive HMG-CoA reductase inhibitor used for the treatment of primary hyper cholesterolemia, and has also been shown to suppress growth in a variety of non-glioma tumor cell lines. A sensitive reversed-phase high-perfonnance liquid chromatographic method with ultraviolet (UV) absorbance detection has been developed to quantitate LOVA in human plasma and urine samples using liquid-liquid extraction procedure. Baseline separation of LOVA and internal standard, simvastatin was achieved on a Novapak $C_{18}$ analytical column with a mobile phase containing 0.025M $NaH_2PO_4$: CAN (35:65, v/v%), adjusted pH to 4.5. The flow rate was set at 1.5ml/min, and the column effluent was monitored by a UV detection at 238nm. The limit of quantification was determined to be 0.5${\mu}$g/ml while extraction efficiency of LOVA ranged from 73.4-82.9% at LOVA concentrations of 0.5 to 10${\mu}$g/ml. Good linearity with correlation coefficients greater than 0.999 was obtained in the range of LOVA concentrations from 0.5 to 10${\mu}$g/ml. The accuracy and the precision were proven excellent with relative standard deviation (RSD, %) and relative error (RE, %) of less than 4.2 and 4.0, respectively. Intraday precision, evaluated at five LOVA concentrations (0.5, 1, 2, 5, 10${\mu}$g/ml) and expressed as RSD ranged from 0-1.82% while the interday precision at the same concentrations ranged from 0.7-10.5%. The analytical method described was then successfully employed for the determination of LOVA concentrations in plasma samples obtained during a phase II clinical trial using high doses of LOVA (30-40mg/kg/day). This method could be further utilized for the ongoing pharmacolkinetic studies and therapeutic drug monitoring of the high-dose LOVA therapy in adenocarcinoma patients.

  • PDF

Opening Status of the Korea Midwifery Birthing Centers and Development of Midwifery Practice Guideline (한국 조산원 개원실태 및 조산직무지침 개발)

  • Song, Ji Young;Park, Young-Joo
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.4
    • /
    • pp.583-598
    • /
    • 2020
  • Purpose: This study was to investigate the operational status of the midwifery birthing centers (MBCs) and midwives' job status (Phase 1) and to develop midwifery practice guidelines (MPG) (Phase 2) in Korea. Methods: In the first phase, the subjects were 15 midwives who operated 11 of 14 MBCs that were opened as of August 2018. The questionnaire consisted of items to measure the operational status of the MBC and midwives' job status. In the second phase, the MPG was developed from literature review, interviews with five midwives opening their MBCs, surveys with 74 midwives, and a validity evaluation conducted by seven experts. Results: The distribution of operating MBCs was five in Gyunggi-do, two each in Seoul and Incheon, one each in Busan, Chungcheongbuk-do, Gyeongsangbuk-do, Gyeongsangnam-do and Jeju-do. The mean age of midwives was 54.3 and all were female. In 2017, a total of 762 births including 81 homebirths were performed by midwives. The job performance was highest in the order of neonatal care 3.81, childbirth care 3.56, and postpartal care 3.53, respectively. The MPG included seven areas of prenatal care, childbirth care, postpartal care, neonatal care, primary health care, law/ethics, and administration, with 56 tasks and 166 task elements. Conclusion: This study provides the valid basic data for the operational status of the MBC and the midwives' job status. The MPG describes the midwife's job and may be used as basic data for preparing policies for the development of midwifery practice in Korea.

Review of Injection-Locked Oscillators

  • Choo, Min-Seong;Jeong, Deog-Kyoon
    • Journal of Semiconductor Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • Handling precise timing in high-speed transceivers has always been a primary design target to achieve better performance. Many different approaches have been tried, and one of those is utilizing the beneficial nature of injection locking. Though the phenomenon was not intended for building integrated circuits at first, its coupling effect between neighboring oscillators has been utilized deliberately. Consequently, the dynamics of the injection-locked oscillator (ILO) have been explored, starting from R. Adler. As many aspects of the ILO were revealed, further studies followed to utilize the technique in practice, suggesting alternatives to the conventional frequency syntheses, which tend to be complicated and expensive. In this review, the historical analysis techniques from R. Adler are studied for better comprehension with proper notation of the variables, resulting in numerical results. In addition, how the timing jitter or phase noise in the ILO is attenuated from noise sources is presented in contrast to the clock generators based on the phase-locked loop (PLL). Although the ILO is very promising with higher cost effectiveness and better noise immunity than other schemes, unless correctly controlled or tuned, the promises above might not be realized. In order to present the favorable conditions, several strategies have been explored in diverse applications like frequency multiplication, data recovery, frequency division, clock distribution, etc. This paper reviews those research results for clock multiplication and data recovery in detail with their advantages and disadvantages they are referring to. Through this review, the readers will hopefully grasp the overall insight of the ILO, as well as its practical issues, in order to incorporate it on silicon successfully.

A Characteristics of Zn-Al-Cu System Pb-free Solder Alloys for Ultra High Temperature Applications (초고온용 Zn-Al-Cu계 Pb-free 솔더 합금의 특성)

  • Kim Seong-Jun;Na Hye-Seong;Han Tae-Kyo;Lee Bong-Keun;Kang Cung-Yun
    • Journal of Welding and Joining
    • /
    • v.23 no.6
    • /
    • pp.93-98
    • /
    • 2005
  • The purpose of this study is to investigate the characteristics of pb-free $Zn-(3\~6)\%Al-(1\~6)\%Cu$ solder alloys for ultra high temperature(>573K) which applied to air craft, space satellite, automotive, oil, gas well exploration and data logging of geo-thermal wells. Melting range, solderability, electric resistivity, microstructure and mechanical properties were examined with solder alloys casted in Ar gas atmosphere. $Zn-4\%Al-(1\~3)\%Cu,\;Zn-5\%Al-(2\~4)\%Cu\;and\;Zn-6\%Al-(3\~5)\%Cu$ alloys satisfied the optimum melting range of 643 to 673k for ultra high temperature solder. A melting temperature increased with increasing Cu content, but decreased with increasing Al content. The spreadability was improved with increasing hi content. But the content of Cu had no effect on the spreadability. The electric resistivity was lowered with increasing Al and decreasing Cu content. In all Zn-Al-Cu solder alloys, primary dendritic $\varepsilon$ phase(Zn-Cu), dendritic $\eta$ phase(Zn-Cu-Al), $\alpha(Al-Zn)-\eta$ eutectic and eutectoid phase were observed. The addition of Al increased the volume fraction of eutectic and eutectoid phase and it decreased f phases. Also, the addition of Cu increased slightly the volume fraction of e, the eutectic and eutectoid phases. With increasing total content of Al and Cu, a hardness and a tensile strength were linearly increased, but anelongation was linearly decreased.

Phase-Shift Full-Bridge DC-DC Converter using the One-Chip Micom (단일칩 마이컴을 이용한 위상변위 방식 풀브리지 직류-직류 전력변환기)

  • Jeong, Gang-Youl
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.517-527
    • /
    • 2021
  • This paper presents the phase-shift full-bridge DC-DC converter using the one-chip micom. The proposed converter primary is the full-bridge power topology that operates with the unipolar pulse-width modulation (PWM) by the phase-shift method, and the secondary is the full-bridge full-wave rectifier composed of four diodes. The control of proposed converter is performed by the one-chip micom and its MOSFET switches are driven by the bootstrap circuit. Thus the total system of proposed converter is simple. The proposed converter achieves high-efficiency using the resonant circuit and blocking capacitor. In this paper, first, the power-circuit operation of proposed converter is explained according to each operation mode. And the power-circuit design method of proposed converter is shown, and the software control algorithm on the micom and the feedback and switch drive circuits operating the proposed converter are described, briefly. Then, the operation characteristics of proposed converter are validated through the experimental results of a designed and implemented prototype converter by the shown design and implementation method in this paper. The highest efficiency in the results was about 92%.

Systematic Review on the Efficacy and Safety of Erenumab for the Prevention of Migraine (편두통 예방을 위한 erenumab의 유효성 및 안전성에 관한 체계적 고찰)

  • Son, Pyoungwoo;Chae, Hyunwoo;Ji, Eunhee;Yoo, Bong Kyu
    • Korean Journal of Clinical Pharmacy
    • /
    • v.29 no.2
    • /
    • pp.71-78
    • /
    • 2019
  • Objective: This study aimed to provide efficacy and safety information on the use of erenumab for prevention of episodic and chronic migraines. Methods: The keywords "Erenumab and migraine" were used to search the PubMed database to then compile efficacy and safety data for erenumab. Data from relevant Phase 2 and Phase 3 clinical trials were analyzed, using RevMan for statistical analysis. Results: Three clinical trials (one Phase 2 and two Phase 3 studies) were retrieved. All three trials used the same primary endpoint (change from baseline in monthly migraine days (CBMD)) to evaluate efficacy and safety of erenumab use for prevention of episodic and chronic migraines. Subcutaneous doses of erenumab (70 or 140 mg) were administered monthly in each trial, for 3 months (Studies 2, and 3) or 6 months (Study 1). The mean differences in CBMD in the 70 mg and 140 mg erenumab arms were -1.36 and -1.98, respectively, compared to that in the placebo arm. Some adverse events, such as nasopharyngitis and upper respiratory tract infection, were reported, but no differences in safety between erenumab and placebo were found to be significant. Conclusions: Erenumab showed superior efficacy in prevention of migraines compared to placebo. However, additional information regarding the long-term safety of erenumab should be collected. Therefore, post-marketing surveillance for adverse events is needed.

Phase II Study of Preoperative Intra-Arterial Epirubicin, Etoposide, and Oxaliplatin Combined with Oral S-1 Chemotherapy for the Treatment of Borrmann Type 4 Gastric Cancer

  • Xiang, Xiao-song;Su, Yu;Li, Guo-li;Ma, Long;Zhou, Chang-sheng;Ma, Ru-feng
    • Journal of Gastric Cancer
    • /
    • v.20 no.4
    • /
    • pp.395-407
    • /
    • 2020
  • Purpose: A phase II study was conducted to evaluate the safety and efficacy of preoperative, intra-arterial perfusion of epirubicin, etoposide, and oxaliplatin combined with oral chemotherapy S-1 (SEEOX) for the treatment of type 4 gastric cancer. Materials and Methods: A single-center, single-arm phase II trial was conducted on 36 patients with histologically proven type 4 gastric cancer without distant peritoneal or organ metastasis. Patients received 3, 21-day courses of SEEOX preoperative chemotherapy. The primary endpoint was overall survival (OS) and the secondary outcomes assessed were chemotherapeutic response, radical resection rate, pathological regression, toxicities, postoperative morbidity, and mortality. Results: All patients were at an advanced stage of cancer (stage III or IV) and completed the entire course of treatment. Based on changes in tumor volume and peritoneal metastasis, the objective response rate was 55.6% (20/36; 95% confidence interval [CI], 38.5%-72.6%) and the disease control rate was 69.4% (25/36; 95% CI, 53.6%-85.3%). The radical resection rate was 75% (27/36; 95% CI, 60.1%-89.9%) and the proportion of R0 resections was 66.7% (21/36; 95% CI, 50.5%-82.8%). The pathological response rate was 33.3%, of which 13.9% showed complete pathological regression. The median survival was 27.1 months (95% CI, 22.24-31.97 months), and the 2-year OS was 48.5% (95% CI, 30.86%-66.1%). Conclusions: Preoperative SEEOX is a safe and effective treatment for type 4 gastric cancer. Based on these preliminary data, a phase III study will be conducted to confirm the superiority of this regimen over standard treatment.

Compensation of the Secondary Voltage of a Three Winding Coupling Capacitor Voltage Transformer (3권선 CCVT의 2차 전압 보상 방법)

  • Kang, Yong-Cheol;Kim, Yeon-Hee;Zheng, Tai-Ying;Jang, Sung-Il;Kim, Yong-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.938-943
    • /
    • 2008
  • Coupling capacitor voltage transformers(CCVTs) have been used in extra or ultra high voltage systems to obtain the standard low voltage signal for protection and measurement. For fast suppression of the phenomenon of ferroresonance, three winding CCVTs are used instead of two winding CCVTs. A tuning reactor is connected between a capacitor voltage divider and a voltage transformer to reduce the phase angle difference between the primary and secondary voltages in the steady state. Slight distortion of the secondary voltage is generated when no fault occurs. However, when a fault occurs, the secondary voltage of the CCVT has significant errors due to the transient components such as dc offset component and/or high frequency components resulting from the fault. This paper proposes an algorithm for compensating the secondary voltage of a three winding CCVT in the time domain. With the values of the measured secondary voltage of the three winding CCVT, the secondary, tertiary and primary currents and voltages are estimated; then the voltages across the capacitor and the tuning reactor are calculated and then added to the measured voltage. Test results indicate that the algorithm can successfully compensate the distorted secondary voltage of the three winding CCVT irrespective of the fault distance, the fault impedance and the fault inception angle as well as in the steady state.

A Study on the ZVS Full Bridge Converters using the New Integrated Magnetics Transformer (새론운 복합변압기를 적용한 영전압 풀브릿지 컨버터에 관한 연구)

  • Ahn, Tae-Young;Bong, Sang-Cheol;Kim, Don-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.396-402
    • /
    • 2008
  • This paper presents the structure and performance of a new Integrated magnetics-based transformer, which can be readily adapted to zero-voltage switching full bridge dc-to-dc converters. The proposed transformer features with two paralleled primary windings and a center-tapped secondary winding. The transformer can be fabricated on standard EE or EI cores where the primary and secondary windings are placed on the outer legs while the output filter inductor is wound on the middle leg. The performance of the proposed transformer is demonstrated with a 100 kHz 720 W experimental dc-to-dc converter which recorded a 92% conversion efficiency at 12 V output voltage.

The Identification of Generation Mechanism of Noise and Vibrtaion and Transmission Characteristics for Engine System - The Source Identification and Noise Reduction of Compartment by Multidimensional Spectral Analysis and Vector Synthesis Method - (엔진의 소음.진동발생기구 및 전달특성 규명 -다차원해석법과 벡터합성법에 의한 차실소음원 규명 및 소음저감 -)

  • O, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.7
    • /
    • pp.1127-1140
    • /
    • 1997
  • With the study for identifying the transmission characteristics of vibration and noise generated by operating engine system of a vehicle, recently many engineers have studied actively the reduction of vibration and noise inducing uncomfortableness to the passenger. In this study, output noise was analyzed by multi-dimensional spectral analysis and vector synthesis method. The multi-dimensional analysis method is very effective in case of identification of primary source, but this method has little effect on suggestion for interior noised reduction. For compensation of this, vector synthesis method was used to obtain effective method for interior noise reduction, after identifying primary source for output noise. In this paper, partial coherence function of each input was calculated to know which input was most coherent to output noise, then with simulation of changes for input magnitude and phase by vector synthesis diagram, the trends of synthesized output vector was obtained. As a result, the change of synthesized output vector could be estimated.