Purpose : The purpose of this study was to investigate the effects of diaphragmatic breathing on activation of lumbar paraspinal muscles of normal healthy people. Diaphragmatic breathing may affect activation of trunk muscles. The assumptions are as follows: the crural diaphragm attatches to the lumbar vertebrae from L1 to L3, the voluntary downward pressurization of the diaphragm increases intra-abdominal pressure, and this increases the stiffness of the spine. Methods : Sixty male college students ranging 19 to 34 years were screened and % maximal voluntary contraction(% MVC) of trunk muscles on the four positions of back extension exercise was compared during the pre and post of inspiration of diaphragmatic breathing. Results : 1. % MVC of right and left erector spinae had the statistically significant difference between pre and post inspiration of diaphragmatic breathing in the dynamic right arm and left leg extension position(p<0.05). 2. % MVC of right and left erector spinae had the statistically significant difference between pre and post inspiration of diaphragmatic breathing in the dynamic left arm and right leg extension position(p<0.05). 3. % MVC of right and left erector spinae had the statistically significant difference between pre and post inspiration of diaphragmatic breathing in the static lying prone extension position(p<0.05). 4. % MVC of right and left erector spinae had the statistically significant difference between pre and post inspiration of diaphragmatic breathing in the static lying on prone position(p<0.05). Conclusion : This study will be used as the purpose of data collection of lumbar paraspinal muscles on diaphragmatic breathing and be introduced as the new therapeutic intervention for management of patients with back pain.
최근 건축물은 대형화, 고층화되어 화재발생시 소방대의 활동이 제한되어 화염 및 연기에 의한 인명피해가 증가할 수 있다. 이러한 인명피해를 저감하기 위하여 제연설비가 필수적이며 특별피난계단 부속실 및 비상용승강기 승강장에 급기 가압제연설비를 적용하고 있다. 국가 화재안전기준에서는 부속실 및 승강장과 거실과의 차압을 40 Pa~60 Pa을 요구하고 있으나 실제 현장에서는 60 Pa 이상의 과압이 다수 발생하고 있다. 이러한 과압의 원인은 댐퍼의 누설량의 과다에 의한 것으로 알려져 있다. 과압은 피난자의 문개방을 어렵게 하여 피난을 불가능하게 할 수 있다. 이러한 문제점을 확인하고자 국내에 사용되고 있는 자동차압 과압조절형댐퍼의 누설량을 측정하여 실제 누설량이 얼마인지 분석하였다. 실험결과 제조사 별로 최대 누설량은 $0.154m^3/s$로 나타났으며, 최소 누설량은 $0.090m^3/s$로 나타났다. 이 누설량으로 인하여 과압이 발생하면 피난문 폐쇄력이 증가하여 피난에 방해가 될 수 있으므로 댐퍼의 누설량 제한 기준이 필요하다.
본 논문은 천리안 위성의 추진계를 간략하게 소개하고 천리안 위성의 발사 및 초기 위성운용 수행 임무 중 위성 추진계의 일련의 과정에서 측정된 원격측정치를 제시한다. 일부 원격측정치는 기 개발된 프로그램의 계산결과와 비교하였다. 추진계의 압력변화는 주로 두단계로 구성된다. 첫 번째 단계는 위성 추진계의 초기화, 즉 안전을 위해서 추진제 탱크 후 단부터 추력기 상단까지 충전된 헬륨 가스를 진공인 우주공간으로 빼는 배출단계를 시작으로, 이 빈 배관망에 산화제와 연료를 각각 채우는 충전단계를 거치고 마지막으로 추진제 탱크의 압력을 일정한 압력까지 올리는 가압단계이다. 두 번째 단계는 목표궤도에 이를 때까지 수행하는 액체원지점엔진의 연소 단계이며, 이 단계에서는 추진제 탱크의 압력을 일정하게 유지 하기 위해서 가압제인 헬륨을 사용한다. 이 프로그램은 향후에 개발되는 정지 궤도복합위성의 기초 설계자료 생성에 사용할 수 있을 것이다.
리포솜은 인지질로 구성된 인위적 세포막으로서, 본 연구에서는 초음파와 압력을 이용하여 나노 리포솜을 제조하였다. 먼저 리포솜을 탈수/재수화법으로 제조하였다. 형성된 multilayer vesilces(MLV)의 크기는 $10{\mu}m$ 이상이었다. Tip-type의 초음파 처리기와 French press를 이용하여 리포솜의 크기를 감소시켰다. MLV에 대한 출력 112.5W, 10분간의 초음파 처리로 리포솜의 크기가 450 nm 이하로 감소되었다. 또한, 6,000 psi 이상의 압력에서는 100 nm 내외의 균일한 리포솜이 생성되었다. 초음파와 가압에 의한 리포솜 용액의 색도는 대체로 명도, 적색도, 황색도가증가하였으며, 육안으로는 점점 더 투명하게 되었다. 이러한 결과는 초음파와 French press를 이용한 가압 처리로 나노 크기의 리포솜을 얻을 수 있음을 의미한다.
Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurization causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. The O-cell pile load test with variable end plate is operated on second steps - the first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell.
The accident at Japan's Fukushima Daiichi nuclear power plant in March 2011, caused by an earthquake and a subsequent tsunami, resulted in a failure of the power systems that are needed to cool the reactors at the plant. The accident progression in the absence of heat removal systems caused Units 1-3 to undergo fuel melting. Containment pressurization and hydrogen explosions ultimately resulted in the escape of radioactivity from reactor containments into the atmosphere and ocean. Problems in containment venting operation, leakage from primary containment boundary to the reactor building, improper functioning of standby gas treatment system (SGTS), unmitigated hydrogen accumulation in the reactor building were identified as some of the reasons those added-up in the severity of the accident. The Fukushima accident not only initiated worldwide demand for installation of adequate control and mitigation measures to minimize the potential source term to the environment but also advocated assessment of the existing mitigation systems performance behavior under a wide range of postulated accident scenarios. The uncertainty in estimating the released fraction of the radionuclides due to the Fukushima accident also underlined the need for comprehensive understanding of fission product behavior as a function of the thermal hydraulic conditions and the type of gaseous, aqueous, and solid materials available for interaction, e.g., gas components, decontamination paint, aerosols, and water pools. In the light of the Fukushima accident, additional experimental needs identified for hydrogen and fission product issues need to be investigated in an integrated and optimized way. Additionally, as more and more passive safety systems, such as passive autocatalytic recombiners and filtered containment venting systems are being retrofitted in current reactors and also planned for future reactors, identified hydrogen and fission product issues will need to be coupled with the operation of passive safety systems in phenomena oriented and coupled effects experiments. In the present paper, potential hydrogen and fission product issues raised by the Fukushima accident are discussed. The discussion focuses on hydrogen and fission product behavior inside nuclear power plant containments under severe accident conditions. The relevant experimental investigations conducted in the technical scale containment THAI (thermal hydraulics, hydrogen, aerosols, and iodine) test facility (9.2 m high, 3.2 m in diameter, and $60m^3$ volume) are discussed in the light of the Fukushima accident.
최근 우리나라 고층아파트에서 많은 문제가 되고 있는 승강장 부속실의 급기가압 시스템에 있어서 거주자의 피난 시나리오에 따른 차압의 변화 및 연기유동 특성을 FDS 화재모델링을 이용하여 현상학적으로 살펴보았다. 자동차압조절댐퍼의 기준압을 화재실로 할 경우 현관문 누설틈새를 통한 공기의 화재실 유입으로 화재실 및 부속실 모두 절대압이 크게 상승하는 결과를 가져왔으며 피난으로 계단실 방화문이 개방 후에는 다시 닫히지 않아 부속실내의 차압형성이 안 되는 문제점이 예상되었다. 따라서 화재실압이 지속적으로 상승하지 않도록 거실에 별도의 개구부가 필요한 것으로 판단된다. 현관문 개방 후 다시 닫힐 시에는 순간적으로 200 Pa 정도의 높은 과압이 형성되어 이 시간 동안에는 화재실 안의 또 다른 거주자가 현관문을 개방하기는 어려울 것으로 예상되었으며, 현관문만 개방 시에는 적정방연풍속이 유지되었으나, 현관문과 계단실 방화문이 동시에 개방되어 있을 경우에는 적정방연풍속이 생성되지 않아 부속실 및 계단실로의 연기유입이 발생하는 것으로 예측되었다.
본 논문에서는 KSR-III 주 엔진 연소시험설비를 활용한 수류시험 및 연소시험 과정에서 극저온 추진제인 액체산소의 냉각단계, 충진단계, 연소시험 공급 단계에서 액체산소의 상태량을 시험설비의 각 위치에서 분석함으로써 향후 안정된 공급을 위한 설비 및 운용조건을 선정하는데 주안점을 두었다. 이를 위해 각 단계에서 기체와 극저온 추진제의 상호 작용이 발생하는 가압탱크에서의 가압기체 및 액체산소의 상태량을 파악하였으며, 연소시험시 엔진 메니폴드에서의 액체산소의 상태량을 분석하였다. 또한 냉각 및 충진시에 대기압 vent에 액체산소의 거동을 파악함으로서 냉각을 효율적으로 할 수 있는 방안을 분석하였다. 또한 산소 공급 설비와 로켓엔진 매니폴드에 정압센서와 동압센서를 장착하여 1KHz의 sampling rate로 측정하였다. 오리피스 사이즈는 지름 32.5mm 38mm, 가압 압력 23Bar, 29Bar, 41Bar에 대해 시험을 수행하였다. 오리피스 사이즈를 증가시키고 가압 압력을 낮춘 결과 엔진 내에 공급되는 액체산소의 섭동량이 감소하는 것이 관찰되었다.
스크램젯 엔진용 초음속 연소기 연구를 위한 직결형, 연속식 연소 시험 설비를 개발하였다. 비행체 속도 마하 5, 연소기 입구 유속 마하 2를 가정하고, 시험 대상 연소기의 유로 단면은 높이 32 mm, 폭 70 mm로 가정하여 설비 요구 조건을 결정하였다. 이에 따라 설비는 유동 전압력 548 kPaA, 전온도 1,320 K, 유량 0.776 kg/s로 설계하였다. 설비는 터보형 압축기, 전기 가열기 및 연소식 가열기와 그 하류에 유동 가속을 위해 장착한 마하 2의 2차원 노즐로 구성하였다. 노즐 상류에서 산소를 추가 공급하여 연소식 공기 가열에 의한 산소 감소를 보상하도록 하였다. 배기는 별도의 감압은 하지 않았다. 저압, 저유량에서의 시운전을 수행하였으며, 설계점 운전은 향후 계획 중에 있다.
3단 터빈배기부 구성은 터빈 플랜지, 열교환기, 배기덕트와 추력노즐로 이루어진다. 냉가스 가압 방식에 비하여 열교환기 가압 방식을 사용함으로서 추진제탱크 가압을 위한 헬륨가스 자체 무게와 저장 탱크 무게가 감소하는 장점이 있기 때문에 발사체에 열교환기를 사용한다. 가스발생기는 추진제 연료과농 조건에서 연소가 이루어지며, 연소가스 중에 그을음이 많이 포함되어 있기 때문에 열교환 효율이 감소하는 것을 고려하여 열교환기를 설계해야 한다. 본 논문에서는 터빈배기부 구성품 배치, 열교환기 내부 구조 및 제작성을 고려한 설계기법, 기 설계된 노즐 설계를 바탕으로 3단 터빈배기부 재 노즐 설계 형상에 대한 장점을 기술하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.