• Title/Summary/Keyword: precision control

Search Result 4,585, Processing Time 0.036 seconds

Contents of vitamin B9 (folate) and B12 (cobalamins) in commonly consumed seafood menus in Korea (한국인 상용 수산물 식단의 비타민 B9과 B12 함량)

  • Park, Eun-Young;Jeong, Bomi;Chun, Jiyeon
    • Journal of Nutrition and Health
    • /
    • v.54 no.2
    • /
    • pp.211-223
    • /
    • 2021
  • Purpose: A total of 39 seafood menus were prepared according to the Korean standard recipe, and analyzed for vitamin B9 (folate) and B12 (cobalamins) contents, using validated applied analytical methods. The menus included Guk/Tang/Jjigae (boiled or stewed dishes, n = 10), Bokkeum (stir-fried dishes, n = 10), Jjim/Jorim (braised or steamed dishes, n = 7), Gui (baked or grilled dishes, n = 7), Twigim (deep-fried dishes, n = 2) and Muchim (dried or blanched-seasoned dishes, n = 3). Methods: The contents of vitamin B9 and B12 in all food samples were determined by the trienzyme extraction-Lactobacillus casei and immunoaffinity-high-performance liquid chromatography/photodiode array detection methods. Analytical quality control was performed in order to assure reliability of the analysis. Results: Accuracy (97.4-100.6% recoveries) and precision (< 6% relative standard deviations for repeatability and reproducibility) of vitamin B9 and B12 analyses were determined to be excellent. The vitamin B9 and B12 contents of the 39 seafood menus evaluated, varied in the range of 1.83-523.08 ㎍/100 g and 0.11-38.30 ㎍/100 g, respectively, depending on the ingredients and cooking methods. The vitamin B9 content was highest in Jomi-gim (523.08 ㎍/100 g), followed by Geonsaeu-bokkeum (128.34 ㎍/100 g) and Janmyeolchi-bokkeum (121.53 ㎍/100 g). Vitamin B12 was detected in all seafood menus, with highest level obtained in Kkomack-jjim (41.58 ㎍/100 g). The seaweed dish was found to have high levels of both vitamin B9 and B12. All assays were performed under strict quality control. Conclusion: Guk and Tang menus, which contain a large amount of water, were relatively lower in the vitamin B9 and B12 contents than the other menus. Bokkeum menus containing various vegetables were high in the vitamin B9 content, but the vitamin B12 content was dependent on the type of seafood used in the menu.

Utilization of Smart Farms in Open-field Agriculture Based on Digital Twin (디지털 트윈 기반 노지스마트팜 활용방안)

  • Kim, Sukgu
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2023.04a
    • /
    • pp.7-7
    • /
    • 2023
  • Currently, the main technologies of various fourth industries are big data, the Internet of Things, artificial intelligence, blockchain, mixed reality (MR), and drones. In particular, "digital twin," which has recently become a global technological trend, is a concept of a virtual model that is expressed equally in physical objects and computers. By creating and simulating a Digital twin of software-virtualized assets instead of real physical assets, accurate information about the characteristics of real farming (current state, agricultural productivity, agricultural work scenarios, etc.) can be obtained. This study aims to streamline agricultural work through automatic water management, remote growth forecasting, drone control, and pest forecasting through the operation of an integrated control system by constructing digital twin data on the main production area of the nojinot industry and designing and building a smart farm complex. In addition, it aims to distribute digital environmental control agriculture in Korea that can reduce labor and improve crop productivity by minimizing environmental load through the use of appropriate amounts of fertilizers and pesticides through big data analysis. These open-field agricultural technologies can reduce labor through digital farming and cultivation management, optimize water use and prevent soil pollution in preparation for climate change, and quantitative growth management of open-field crops by securing digital data for the national cultivation environment. It is also a way to directly implement carbon-neutral RED++ activities by improving agricultural productivity. The analysis and prediction of growth status through the acquisition of the acquired high-precision and high-definition image-based crop growth data are very effective in digital farming work management. The Southern Crop Department of the National Institute of Food Science conducted research and development on various types of open-field agricultural smart farms such as underground point and underground drainage. In particular, from this year, commercialization is underway in earnest through the establishment of smart farm facilities and technology distribution for agricultural technology complexes across the country. In this study, we would like to describe the case of establishing the agricultural field that combines digital twin technology and open-field agricultural smart farm technology and future utilization plans.

  • PDF

Optogenetics: a New Frontier for Cell Physiology Study (광유전학: 세포 생리 연구를 위한 새로운 frontier)

  • Byun, Jonghoe
    • Journal of Life Science
    • /
    • v.25 no.8
    • /
    • pp.953-959
    • /
    • 2015
  • Optogenetics is the combination of optical and molecular strategies to control designated molecular and cellular activities in living tissues and cells using genetically encoded light-sensitive proteins. It involves the use of light to rapidly gate the membrane channels that allows for ion movement. Optogenetics began with the placing of light-sensitive proteins from green algae inside specific types of brain cells. The cells can then be turned on or off with pulses of blue and yellow light. Using the naturally occurring algal protein Channelrhodopsin-2 (ChR2), a rapidly gated light-sensitive cation channel, the number and frequency of action potentials can be controlled. The ChR2 provides a way to manipulate a single type of neuron while affecting no others, an unprecedented specificity. This technology allows the use of light to alter neural processing at the level of single spikes and synaptic events, yielding a widely applicable tool for neuroscientists and biomedical engineers. An improbable combination of green algae, lasers, gene therapy and fiber optics made it possible to map neural circuits deep inside the brain with a precision that has never been possible before. This will help identify the causes of disorders like depression, anxiety, schizophrenia, addiction, sleep disorder, and autism. Optogenetics could improve upon existing implanted devices that are used to treat Parkinson’s disease, obsessive-compulsive disorder and other ailments with pulses of electricity. An optogenetics device could hit more specific subsets of brain cells than those devices can. Applications of optogenetic tools in nonneuronal cells are on the rise.

Determination of Betaine in Fructus Lycii Using Hydrophilic Interaction Liquid Chromatography with Evaporative Light Scattering Detection

  • Shin, Hyun-Du;Suh, Joon-Hyuk;Kim, Jung-Hyun;Lee, Hye-Yeon;Eom, Han-Young;Kim, Un-Yong;Yang, Dong-Hyug;Han, Sang-Beom;Youm, Jeong-Rok
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.553-558
    • /
    • 2012
  • A simple new method was developed for the determination of betaine in Fructus Lycii using hydrophilic interaction liquid chromatography with evaporative light scattering detection (HILIC-ELSD). Good chromatographic separation and reasonable betaine retention was achieved on a Kinetex HILIC column ($2.1{\times}100mm$, $2.6{\mu}m$) packed with fused-core particle. The mobile phase consisted of (A) acetonitrile and (B) 10 mM ammonium formate (pH 3.0)/acetonitrile (90/10, v/v). It was used with gradient elution at a flow rate of 0.7 mL/min. The column temperature was set at $27.5^{\circ}C$ and the injection volume was $10{\mu}L$. The ELSD drift tube temperature was $50^{\circ}C$ and the nebulizing gas (nitrogen) pressure was 3.0 bar. Stachydrine, a zwitterionic compound, was used as an internal standard. Calibration curve over $10-250{\mu}g/mL$ showed good linearity ($R^2$ > 0.9992) and betaine in the 70% methanol extract of Fructus Lycii was well separated from other peaks. Intraand inter-day precision ranged from 1.1 to 3.0% and from 2.4 to 5.3%, respectively, while intra- and inter-day accuracy ranged from 100.0 to 107.0% and from 94.3 to 103.9%, respectively. The limit of quantification (LOQ) was $10{\mu}g/mL$ and the recoveries were in the range of 98.2-102.7%. The developed HILIC-ELSD method was successfully applied to quantitatively determine the amount of betaine in fourteen Fructus Lycii samples from different locations, demonstrating that this method is simple, rapid, and suitable for the quality control of Fructus Lycii.

HPLC Method for Simultaneous Quantitative Detection of Quercetin and Curcuminoids in Traditional Chinese Medicines

  • Ang, Lee Fung;Yam, Mun Fei;Fung, Yvonne Tan Tze;Kiang, Peh Kok;Darwin, Yusrida
    • Journal of Pharmacopuncture
    • /
    • v.17 no.4
    • /
    • pp.36-49
    • /
    • 2014
  • Objectives: Quercetin and curcuminoids are important bioactive compounds found in many herbs. Previously reported high performance liquid chromatography ultraviolet (HPLC-UV) methods for the detection of quercetin and curcuminoids have several disadvantages, including unsatisfactory separation times and lack of validation according the standard guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. Methods: A rapid, specific, reversed phase, HPLC-UV method with an isocratic elution of acetonitrile and 2% v/v acetic acid (40% : 60% v/v) (pH 2.6) at a flow rate of 1.3 mL/minutes, a column temperature of $35^{\circ}C$, and ultraviolet (UV) detection at 370 nm was developed. The method was validated and applied to the quantification of different types of market available Chinese medicine extracts, pills and tablets. Results: The method allowed simultaneous determination of quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin in the concentration ranges of $0.00488-200{\mu}g/mL$, $0.625-320{\mu}g/mL$, $0.07813-320{\mu}g/mL$ and $0.03906-320{\mu}g/mL$, respectively. The limits of detection and quantification, respectively, were 0.00488 and $0.03906{\mu}g/mL$ for quercetin, 0.62500 and $2.50000{\mu}g/mL$ for bisdemethoxycurcumin, 0.07813 and $0.31250{\mu}g/mL$ for demethoxycurcumin, and 0.03906 and $0.07813{\mu}g/mL$ for curcumin. The percent relative intra day standard deviation (% RSD) values were $0.432-0.806{\mu}g/mL$, $0.576-0.723{\mu}g/mL$, $0.635-0.752{\mu}g/mL$ and $0.655-0.732{\mu}g/mL$ for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and those for intra day precision were $0.323-0.968{\mu}g/mL$, $0.805-0.854{\mu}g/mL$, $0.078-0.844{\mu}g/mL$ and $0.275-0.829{\mu}g/mL$, respectively. The intra day accuracies were 99.589%-100.821%, 98.588%-101.084%, 9.289%-100.88%, and 98.292%-101.022% for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and the inter day accuracy were 99.665%-103.06%, 97.669%-103.513%, 99.569%-103.617%, and 97.929%-103.606%, respectively. Conclusion: The method was found to be simple, accurate and precise and is recommended for routine quality control analysis of commercial Chinese medicine products containing the flour flavonoids as their principle components in the extracts.

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Simultaneous determination of illegal galactagogue adulterants in supplement diets by LC-MS/MS

  • Lee, Ji Hyun;Cho, So-Hyun;Park, Han Na;Park, Hyoung Joon;Kim, Nam Sook;Park, Sung Kwan;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.171-178
    • /
    • 2018
  • Recently, for successful lactation, many breastfeeding mothers seek various products, including herbal medicine, dietary supplements, and prescribed medicines, to improve milk production. As demand for galactogogues grows, it is highly possible that pharmaceutical galactogogues may be adulterated with illegal products to maximize their efficacy. For continuous control and supervision of illegal products, we developed and validated a simple and sensitive LC-MS/MS method capable of simultaneously determining five galactogogues. Chromatographic separation was conducted using an Agilent Poroshell $120SB-C_{18}$ column with a mobile phase consisting of 20 mM ammonium formate (pH 5.4) and 100 % acetonitrile. The total run time was 13 min per analyte. The proposed method was performed according to the guidelines of the International Conference of Harmonization and it produced reliable results. This method showed high sensitivity and specificity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 0.01-0.82 ng/mL and 0.02-2.45 ng/mL, respectively, for the solid- and liquid-type samples. Specificity was evaluated by analyzing matrix-blank samples spiked with the target compounds at LOQ levels, which provided a good separation of all peaks without interference. Additionally, the repeatability and intermediate precision were typically <15 %, whereas the recovery was 80-120 % of the values obtained using blank samples. Thus, we concluded that this method could be used for the identification and quantification of galactogogues in food or herbal products.

Domestic Intercomparison Study for the Performance of Personnel Dosimeters (개인선량계 성능의 국내 상호비교)

  • Kim, Jang-Lyul;Chang, Si-Young;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.147-153
    • /
    • 1996
  • The Korea Atomic Energy Research Institute(KAERI) conducted a intercomparison study for personnel dosimetry services in Korea to enhance the accuracy and precision of the dosimetry system. Nine types of dosimeters(6 TLD, 3 film badge) from 7 institutions took part in this intercomparison study. Each participant submitted 30 dosimeters including transit control for irradiations. Both TLDs and film badges were irradiated with Cs-137 gamma, Sr/Y-90 beta and 4 X-ray beams in ISO wide series. Four dosimeters were irradiated on phantom with same dose equivalent for each field category. The delivered dose equivalent was in the range of $0.1{\sim}10mSv$. The participants assessed the results of their dosimeter readings in terms of the ICRU operational quantities for personal monitoring, Hp(10) and Hp(0.07). Most participants except 1 dosimeter estimated the delivered dose equivalent with biases less than ${\pm}25%$ for Cs-137 and Sr/Y-90. But for X-rays, the biases exceeded ${\pm}35%$ in some cases bacause the dose evaluation algorithm was based on the ANSI N13.11 X-ray fields which are different from those given by ISO.

  • PDF

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF

GPS receiver and orbit determination system on-board VSOP satellite

  • Nishimura, Toshimitsu;Harigae, Masatoshi;Maeda, Hiroaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1649-1654
    • /
    • 1991
  • In 1995 the VSOP satellite, which is called MUSES-B in Japan, will be launched under the VLBI Space Observatory Programme(VSOP) promoted by ISAS(Institute of Space and Astronautical Science) of Japan. We are now developing the GPS Receiver(GPSR) and On-board Orbit Determination System. This paper describes the GPS(Global Positioning System), VSOP, GPSR(GPS Receiver system) configuration and the results of the GPS system analysis. The GPSR consists of three GPS antennas and 5 channel receiver package. In the receiver package, there are two 16 bits microprocessing units. The power consumption is 25 Watts in average and the weight is 8.5 kg. Three GPS antennas on board enable GPSR to receive GPS signals from any NAVSTARs(GPS satellites) which are visible. NAVSATR's visibility is described as follows. The VSOP satellite flies from 1, 000 km to 20, 000 km in height on the elliptical orbit around the earth. On the other hand, the orbit of NAVSTARs are nearly circular and about 20, 000 km in height. GPSR can't receive the GPS signals near the apogee, because NAVSTARs transmit the GPS signals through the NAVSTAR's narrow beam antennas directed toward the earth. However near the perigee, GPSR can receive from 12 to 15 GPS signals. More than 4 GPS signals can be received for 40 minutes, which are related to GDOP(Geometric Dillusion Of Precision of selected NAVSTARs). Because there are a lot of visible NAVSTARs, GDOP is small near the perigee. This is a favorqble condition for GPSR. Orbit determination system onboard VSOP satellite consists of a Kalman filter and a precise orbit propagator. Near the perigee, the Kalman filter can eliminate the orbit propagation error using the observed data by GPSR. Except a perigee, precise onboard orbit propagator propagates the orbit, taking into account accelerations such as gravities of the earth, the sun, the moon, and other acceleration caused by the solar pressure. But there remain some amount of calculation and integration errors. When VSOP satellite returns to the perigee, the Kalman filter eliminates the error of the orbit determined by the propagator. After the error is eliminated, VSOP satellite flies out towards an apogee again. The analysis of the orbit determination is performed by the covariance analysis method. Number of the states of the onboard filter is 8. As for a true model, we assume that it is based on the actual error dynamics that include the Selective Availability of GPS called 'SA', having 17 states. Analytical results for position and velocity are tabulated and illustrated, in the sequel. These show that the position and the velocity error are about 40 m and 0.008 m/sec at the perigee, and are about 110 m and 0.012 m/sec at the apogee, respectively.

  • PDF