• 제목/요약/키워드: precious metal

검색결과 201건 처리시간 0.027초

Ionic liquid coated magnetic core/shell CoFe2O4@SiO2 nanoparticles for the separation/analysis of trace gold in water sample

  • Zeng, Yanxia;Zhu, Xiashi;Xie, Jiliang;Chen, Li
    • Advances in nano research
    • /
    • 제10권3호
    • /
    • pp.295-312
    • /
    • 2021
  • A new ionic liquid functionalized magnetic silica nanoparticle was synthesized and characterized and tested as an adsorbent. The adsorbent was used for magnetic solid phase extraction on ICP-MS method. Simultaneous determination of precious metal Au has been addressed. The method is simple and fast and has been applied to standard water and surface water analysis. A new method for separation/analysis of trace precious metal Au by Magnetron Solid Phase Extraction (MSPE) combined with ICP-MS. The element to be tested is rapidly adsorbed on CoFe2O4@SiO2@[BMIM]PF6 composite nano-adsorbent and eluted with thiourea. The method has a preconcentration factor of 9.5-fold. This method has been successfully applied to the determination of gold in actual water samples. Hydrophobic Ionic Liquids (ILs) 1-butyl-3-methylimidazole hexafluorophosphate ([BMIM]PF6) coated CoFe2O4@SiO2 nanoparticles with core-shell structure to prepare magnetic solid phase extraction agent (CoFe2O4@SiO2@ILs) and establish a new method of MSPE coupled with inductively coupled plasma mass spectrometry for separation/analysis of trace gold. The results showed that trace gold was adsorbed rapidly by CoFe2O4@SiO2@[BMIM]PF6 and eluanted by thiourea. Under the optimal conditions, preconcentration factor of the proposed method was 9.5-fold. The linear range, detection limit, correlation coefficient (R) and relative standard deviation (RSD) were found to be 0.01~1000.00 ng·mL-1, 0.001 ng·mL-1, 0.9990 and 3.4% (n = 11, c = 4.5 ng·mL-1). The CoFe2O4@SiO2 nanoparticles could be used repeatedly for 8 times. This proposed method has been successfully applied to the determination of trace gold in water samples.

전기화학적 물 분해 시스템에서 산소발생반응을 위한 Co와 Mo 기반 촉매의 최근 연구 동향 (Research on Co- and Mo-Based Catalysts for the Oxygen Evolution Reaction in Electrochemical Water Splitting System)

  • 박준성;정원석;부종찬
    • 전기화학회지
    • /
    • 제26권4호
    • /
    • pp.64-70
    • /
    • 2023
  • 급격한 온실가스 배출량 증가로 인해 지구 온난화가 심화되고 있다. 이로 인해 탄소중립의 필요성과 이행이 더욱 절실해졌다. 이를 위해 여러 가지 신재생에너지 중 수소에 대한 관심이 부각되고 있다. 수소는 지구 상에 풍부한 자원이며 무탄소 전원으로 친환경적이다. 궁극적으로 물의 전기분해에 의해 친환경 수소를 얻을 수 있다. 하지만 산소 발생 반응에 사용되는 촉매는 고가이며 희귀하고 촉매의 내구성에 문제가 있어 어려움을 겪고 있기 때문에 비귀금속 촉매의 개발이 필요하다. 본 총설에서는 최근 발표된 산소 발생 촉매 중 비귀금속 촉매인 Co와 Mo 기반의 촉매를 정리, 요약하여 소개하고 있다. 이를 통해 비귀금속 촉매의 활성과 내구성을 증가시키기 위한 촉매의 특성 설계를 이해하는 데 도움이 될 것이다.

베릴륨 불포함 치과 주조용 니켈-크롬 합금 중 금속의치상용 합금과 금속소부도재관용 합금의 부식에 관한연구 (Corrosion of the non-beryllium dental casting Ni-Cr alloys for the denture base framework metal and the porcelain-fused-to-metal crown)

  • 김홍식;송재상;박수철
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.337-344
    • /
    • 2012
  • Purpose: This study examined the corrosion level by alloy type and pH, and used the corrosion levels as the dental health data. The study utilized one Ni-Cr alloy for the full and removable partial denture metal frameworks and two Ni-Cr alloys for porcelain-fused-to-metal crown, among the non-beryllium dental casting non-precious Ni-Cr alloys. Methods: The alloy specimens were manufactured in $10cm^2$ and stored in the corrosive solution(pH 2.2-4.4) in the electrical water bath($37^{\circ}C$) for seven days. Afterwards, the metal ions were quantitatively analyzed using the ICP. Results: Of the three metal alloys, Bellabond-Plus$^{(R)}$alloy and SOLIBOND N$^{(R)}$alloy, with 22% or higher chrome chemical contents, had higher corrosion resistance than Jdium-100$^{(R)}$alloy with 20% chrome chemical content. In all three alloys, the corrosion of Ni was highest, and metal ion corrosion was higher in the pH 2.2 corrosive solution. Conclusion: Although Ni-Cr alloy was not very corrosive, a Ni-allergic patient should not have Ni-Cr alloy prosthesis. The Ni-Cr alloy for porcelain-fused-to-metal crown should be designed for the dental porcelain to cover the whole crown.

Bond and fracture strength of metal-ceramic restorations formed by selective laser sintering

  • Bae, Eun-Jeong;Kim, Ji-Hwan;Kim, Woong-Chul;Kim, Hae-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.266-271
    • /
    • 2014
  • PURPOSE. The purpose of this study was to compare the fracture strength of the metal and the bond strength in metal-ceramic restorations produced by selective laser sintering (SLS) and by conventional casting (CAST). MATERIALS AND METHODS. Non-precious alloy (StarLoy C, DeguDent, Hanau, Germany) was used in CAST group and metal powder (SP2, EOS GmbH, Munich, Germany) in SLS group. Metal specimens in the form of sheets ($25.0{\times}3.0{\times}0.5mm$) were produced in accordance with ISO 9693:1999 standards (n=30). To measure the bond strength, ceramic was fired on a metal specimen and then three-point bending test was performed. In addition, the metal fracture strength was measured by continuing the application of the load. The values were statistically analyzed by performing independent t-tests (${\alpha}=.05$). RESULTS. The mean bond strength of the SLS group (50.60 MPa) was higher than that of the CAST group (46.29 MPa), but there was no statistically significant difference. The metal fracture strength of the SLS group (1087.2 MPa) was lower than that of the CAST group (2399.1 MPa), and this difference was statistically significant. CONCLUSION. In conclusion the balling phenomenon and the gap formation of the SLS process may increase the metal-ceramic bond strength.

Ta$_2$O$_5$ 박막전해질 EC 창의 전기화학 및 광학적 특성에 관한 연구 (Electrohemical and optical properties of Ta$_2$O$_5$ thin film electrolyte EC windows)

  • 김용혁;백지흠;조원일;윤경석;박인철;주재백
    • 한국표면공학회지
    • /
    • 제30권4호
    • /
    • pp.231-238
    • /
    • 1997
  • Tantalum oxide thin filme has an amorphous structure and a high resistivity. Its stoichiometric structure was $Ta_2O_{5.3}$ and the transmission ratio was 80%. The high resistivity of $Ta_2O_{5.3}$ thin film electrolyte made an EC windows without electrical shottness, but the bleached/colored cur rent was very low because of the low ion conductivith. Upon adding moisture into the system, the $\Delta$T increased upto 25 %. proton concentration increase was the main cases to improve optical property. The influence of adding precious or transition metal film(~100 $\AA$ thickness) in $Ta_2O_5$layer on the color change performance was observed. The metal insertion layers had formed hydroxide and they behaved as a stable proton source. The transmission diffrnece and cycle life were greatly enhanced in the case of Ti inssertion.The $\Delta$T was 50% and the cycle life was 18, 000.

  • PDF

도재소부금관용 비귀금속 합금의 반복주조가 강도에 미치는 영향 (The Impacts of the Recasting of Non-precious Metal Alloy for Porcelain Fused to Metal Crowns on Strength)

  • 정희선;오경재
    • 대한치과기공학회지
    • /
    • 제31권3호
    • /
    • pp.27-34
    • /
    • 2009
  • This study compared and analyzed changes to the mechanical characteristics to nonprecious metal alloy for porcelain fused to metal crowns when it's repetitively used without the addition of new alloy. Metal samples were made with the Verabond V nonprecious metal alloy. Those samples to measure tensile and yield strength were made in the standardized design(ISO 22674), those to measure bond strength in the $25mm{\times}3mm{\times}0.5mm$ format, and those to measure hardness in the $10mm{\times}10mm{\times}1mm$ format. A ceramic to measure bond strength was made at the center of the metal sample in the length of $8{\ss}{\AE}$ by using Noritaker Super Porcelain EX-3. Ten samples were prepared for one, three and five repetitions of casting each. The test results were as follows: 1. The more casting was repeated, the more significantly tensile strength dropped. 2. The more casting was repeated, the more significantly yield strength dropped. 3. Repetitive casting didn't cause significant changes to bond strength. 4. The Vickers hardness significantly fell with increasing repetitions of casting. There were no changes to bond strength observed with the increasing number of repeating casting. But tensile strength, yield strength, and Vickers hardness decreased. Those results indicate that repeated casting can affect durability and that careful attention should be paid by avoiding repetitive use or excessive increase of uses when no new alloy is added.

  • PDF

Sinfony 간접복합수지와 비귀금속합금간의 전단결합강도와 파절양상 (Shear Bond Strength and Failure Mode between Sinfony Indirect Composite Resin and Non Precious Metal)

  • 민병록;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.79-86
    • /
    • 2008
  • The purpose of this study was to investigate the effect retention element formed by metal surface treatment method on the bond strength of indirect composite resin and metal. The metal specimens were cast from Ni-Cr alloy($Rexillium^{(R)}$ III). They were divided into 5 groups by applied retention element: $50{\mu}m$ aluminium oxide sandblasting group, $250{\mu}m$ aluminium oxide sandblasting group, 0.2mm retention crystal group, 10% $H_{2}SO_{4}$ solution etching group, $110{\mu}m$ $Rocatec^{TM}$ Plus system group. Total 50 metal specimens were veneered with Sinfony indirect composite resin system. Specimens were tested for shear bond strength on an Instron universal testing machine and fracture mode of fractured specimens were analyzed by SEM and EDS. 1. 0.2 mm retention crystals were most effective in improving the resin-metal shear bond strength (p<0.05). 2. Sandblasting by $250{\mu}m$ aluminium oxide were more effective than sandblasting by $50{\mu}m$ aluminium oxide in improving the resin-metal shear bond strength(p<0.05). 3. Fracture mode of resin-metal fractured surface were cohesive failure mode in 0.2mm retention crystal, mixed failure mode in sandblasted specimens, etched specimens and the specimens sandblasted with $110{\mu}m$ $Rocatec^{TM}$ Plus system.

  • PDF

치관보철물 제작에 사용되는 비귀금속합금의 주조성에 관한 실험적 연구(III) - 합금 재사용에 따른 주조성과 물리적 특성의 변화 - (The experimental research on the castability of non precious metal alloy which is use for the production of crown and bridge prosthetics(III) - The change of castability and physical properties according to the recasting. -)

  • 정연성
    • 대한치과기공학회지
    • /
    • 제9권1호
    • /
    • pp.21-29
    • /
    • 1987
  • The purpose of this investigation was to determine the effect of recasting on the castability and physical properties of the nonprecious metal alloy. Using 2 sorts of the nonprecious metal alloy for production of Crown and Bridge prosthetics, such as 1) sankin C. B 80 metal 2) C & B alloy, the result of experimental research on the castability and hardness according to the recasting, is as followes; 1. The difference of castability between sankin CB80 metal and C & B alloy was statistically significant (p < 0.01) and the difference of castability among the test groups, was statistically significant (p <0.01). 2. In the case of sankin C.B 80 metal, the difference of castability among the New alloy and first mixed alloy and second mixed alloy and old alloy was not significant statistically (p >0.05). 3. In the case of C & B alloy, the difference of castability among the New alloy and mixed alloys and old alloy, was not significant statistically (p >0.05). 4. The difference of hardness between sankin C & B alloy was not significant statistically (p >0.05), but the difference of hardness among the test groups was statistically significant (p <0.01). 5. In the case of Sankin C.B 80 metal, the difference of hardness among the new ally and mixed alloys and old alloy was not significant statistically (p >0.05). 6. In the case of C & B alloy, the difference of hardness between New alloy and mixed alloys was not significant statistically (p >0.05) but the difference of hardness among the old alloy and New alloy and mixed alloys was statistically significant (p <0.01).

  • PDF

폐휴대폰 내의 인쇄회로기판에 함유된 금속 성분의 변화 (Characterization of Metal Composition in Spent Printed Circuit Boards of Mobile Phones)

  • 정진기;이재천;최준철
    • 자원리싸이클링
    • /
    • 제24권3호
    • /
    • pp.76-80
    • /
    • 2015
  • 오늘날 개인의 필수 품목이 된 휴대폰은 국내에서 매년 2,000만대 이상이 폐기되는 것으로 추정되고 있다. 휴대폰에는 유가금속 뿐만 아니라 유해금속이 들어있기 때문에 적절한 재활용이 필요하다. 휴대폰에 함유된 유용금속성분의 함량에 따라 재활용공정에서의 경제성이 달라지기에 성분의 분석이 중요하다. 본 연구에서는 폐휴대폰에 함유된 금속 성분의 년도별 변화를 보았다. 2000년에서 2009년에 제조된 휴대폰을 대상으로 휴대폰내의 인쇄회로기판의 성분과 함량을 조사하고 함량의 변화추이를 확인하였다. 분석결과 귀금속인 팔라듐과 중금속인 납의 함량은 감소하는 경향을 보였다.

Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy

  • Minesaki, Yoshito;Murahara, Sadaaki;Kajihara, Yutaro;Takenouchi, Yoshihisa;Tanaka, Takuo;Suzuki, Shiro;Minami, Hiroyuki
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the efficacy of two different metal conditioners for non-precious metal alloys for the bonding of porcelain to a cobalt-chromium (Co-Cr) alloy. MATERIALS AND METHODS. Disk-shaped specimens ($2.5{\times}10.0mm$) were cast with Co-Cr alloy and used as adherend materials. The bonding surfaces were polished with a 600-grid silicon carbide paper and airborne-particle abraded using $110{\mu}m$ alumina particles. Bonding specimens were fabricated by applying and firing either of the metal conditioners on the airborne-particle abraded surface, followed by firing porcelain into 5 mm in diameter and 3 mm in height. Specimens without metal conditioner were also fabricated. Shear bond strength for each group (n=8) were measured and compared (${\alpha}=.05$). Sectional view of bonding interface was observed by SEM. EDS analysis was performed to determine the chemical elements of metal conditioners and to determine the failure modes after shear test. RESULTS. There were significant differences among three groups, and two metal conditioner-applied groups showed significantly higher values compared to the non-metal conditioner group. The SEM observation of the sectional view at bonding interface revealed loose contact at porcelain-alloy surface for non-metal conditioner group, however, close contact at both alloy-metal conditioner and metal conditioner-porcelain interfaces for both metal conditioner-applied groups. All the specimens showed mixed failures. EDS analysis showed that one metal conditioner was Si-based material, and another was Ti-based material. Si-based metal conditioner showed higher bond strengths compared to the Ti-based metal conditioner, but exhibited more porous failure surface failure. CONCLUSION. Based on the results of this study, it can be stated that the application of metal conditioner is recommended for the bonding of porcelain to cobalt-chromium alloys.