• 제목/요약/키워드: power-on rising time

검색결과 106건 처리시간 0.029초

가포화 자기스위치 MPC를 적용한 저온 플라즈마의 펄스에너지 전송효율 특성 (The Study on the Optimal Transmission Efficiency Characteristics of Pulse Energy Using Magnetic Pulse Compressors)

  • 이유수;정종한;정현주;김문환;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.383-387
    • /
    • 2003
  • In this paper, we have studied about optimal transmission efficiency characteristics of pulse energy in a coal plant for removing environmental polluted gas. The electrical efficiency of pulse power systems depends on impedance of the reactor. To obtain high efficiency, we used MPC(Magnetic pulse compressor) as the power switch and tested their characteristics as electrode length of the reactor and charging voltage of capacitor, As results, we obtained a compressed pulse such as pulse voltage of 10㎸, rising time 200ns and pulse width of 500ns. With increasing electrode length, the load impedance was decreased but the electrical efficiency was increased.

대용량 IGBT 스위칭 시 과전압 제한을 위한 향상된 게이트 구동기법 (An Improved Gate Control Scheme for Overvoltage Clamping Under High Power IGBTs Switching)

  • 김완중;최창호;이요한;현동석
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.222-230
    • /
    • 1998
  • 본 논문에서는 스너버 회로를 사용하지 않고 턴-온시 역회복 전류의 영향과 턴-오프 시 구동되는 IGBT에 발생하는 과전압을 제한할 수 있는 새로운 IGBT 게이트 구동회로를 제안한다. 제안하는 턴-온 게이트 구동기법은 턴-온 지연 시간을 증가시키지 않고 게이트-에이터 전압이 문턱전압 이상이 되면 IGBT의 입력 커패시턴스를 증가시킴으로써 게이트-에이터 전압의 증가율을 감소시키는 특징을 갖는다. 제안하는 턴-오프 게이트 구동기법은 전류의 크기에 따라 과전압을 제한하여 단락사고와 같은 대전류가 흐르는 경우 더욱 효과적으로 과전압을 제한하는 특징을 가진다. 또한, 여러 가지 조건에서 실험을 수행하여 제안한 IGBT 게이트 구동회로의 타당성을 검증한다.

  • PDF

Blumlein 회로로 구성한 단방향 구형파 펄스 발생기 (Directonal Square Pulse Generator construct for Blumlein lain)

  • 김정달;장기혁;주성철;정장근;이덕진;이용길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1779-1781
    • /
    • 1998
  • We are going to design the Square Pulse Generator use of PCPS (Photo-Conductive Power Switch) for Blumlein lain. The circeuit is made of LC device and it is simulated by Schematics Evaluation Version 8.0 of MicroSim. After charged by DC voltage 15[kV]. When the switch is ON, Square pulse is generated after pause time 1.7857[${\mu}s$]. The square pulse is maximum peak voltage 13.987[kV], pulsed width 3.4017[${\mu}s$], rising time 0.7474[${\mu}s$], falling time 1.1718[${\mu}s$].

  • PDF

Moving Mesh를 이용한 PCV 밸브의 내부유동 수치해석 (A numerical analysis for internal fluid flow of a PCV valve by using moving mesh)

  • 이종훈;최윤환;이연원
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.40-44
    • /
    • 2005
  • A great deal of exhaust gas inside a combustion room goes out through exhaust pipe but residual gas, is called "Blowby gas", enters the crankcase through a small gap between the piston and the cylinder wall. Here, if the crankcase isn't vented, this causes many bad effects such as lubricant oil contamination, corrosion by that and crankcase explosion by rising pressure. So, most automobiles are constituted with a PCV (Positive Crankcase Ventilation) system to prevent previous problems. PCV valve is the most important part in this ventilation system. When companies are manufacturing new engines, engineers are designing it depending on their experiments than theoretical knowledge. Mush efforts and times are needed for new development. This study will show quantitative results to increase the possibilities of reduction of developing time.

  • PDF

소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성 (The Impulse Output Characteristics using Cascading Method of Compact Transformer)

  • 정종한;김휘영;홍정환;박구렬;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

Vibration of multilayered functionally graded deep beams under thermal load

  • Bashiri, Abdullateef H.;Akbas, Seref D.;Abdelrahman, Alaa A.;Assie, Amr;Eltaher, Mohamed A.;Mohamed, Elshahat F.
    • Geomechanics and Engineering
    • /
    • 제24권6호
    • /
    • pp.545-557
    • /
    • 2021
  • Since the functionally graded materials (FGMs) are used extensively as thermal barriers in many of applications. Therefore, the current article focuses on studying and presenting dynamic responses of multilayer functionally graded (FG) deep beams placed in a thermal environment that is not addressed elsewhere. The material properties of each layer are proposed to be temperature-dependent and vary continuously through the height direction based on the Power-Law function. The deep layered beam is exposed to harmonic sinusoidal load and temperature rising. In the modelling of the multilayered FG deep beam, the two-dimensional (2D) plane stress continuum model is used. Equations of motion of deep composite beam with the associated boundary conditions are presented. In the frame of finite element method (FEM), the 2D twelve-node plane element is exploited to discretize the space domain through the length-thickness plane of the beam. In the solution of the dynamic problem, Newmark average acceleration method is used to solve the time domain incrementally. The developed procedure is verified and compared, and an excellent agreement is observed. In numerical examples, effects of graduation parameter, geometrical dimension and stacking sequence of layers on the time response of deep multilayer FG beams are investigated with temperature effects.

아킬레스건 파열 이후의 능동적인 관절 범위 운동이 없는 간단한 재활 운동 방법 (Simple Postoperative Exercise of Acute Achilles Tendon Rupture without Active Range of Motion Exercise)

  • 황재광;정영주;서동교
    • 대한족부족관절학회지
    • /
    • 제27권1호
    • /
    • pp.12-16
    • /
    • 2023
  • Purpose: Postoperative exercise for acute Achilles tendon rupture is important for a patient's return to daily life and sports. On the other hand, the protocol requires considerable effort to educate patients and continuous checking. This study evaluated the outcome of a new simple and delayed rehabilitation protocol after Achilles tendon rupture repair. Materials and Methods: From July 2014 to November 2020, one hundred eighty-three patients were operated on by one surgeon. The exercise protocol was classified into two methods. One group (immediate protocol, control group) started immediate full weight bearing with a 20° plantar flexion range of motion from two days postoperatively. Ankle dorsiflexion was restricted to 0°. The other group (delayed protocol, case group) started full weight bearing with a controlled ankle motion boot from two weeks postoperatively. No range of motion exercise was allowed until six weeks postoperatively. Age, sex, body mass index, ankle range of motion, muscle power, time to return to previous physical activity, functional score, and complication rate were evaluated. The results of the two groups were compared using a Mann-Whitney test. Statistical significance was set as p<0.05. Results: The range of motion, double heel rising, and one-leg standing were achieved faster in the control group (p<0.05). However, single-heel rising, repeated single-heel rising, return to previous activity (work, run, and sport), and functional scores showed no statistical difference (p>0.05). Conclusion: Simple and delayed postoperative rehabilitation of acute Achilles tendon rupture without active range of motion exercises showed satisfactory functional results and a low complication rate.

고효율 LED를 이용한 유도등의 원격제어에 관한 연구 (A Study on the Remote Control for Exit Sign Using High Efficiency LED)

  • 백동현;홍석표
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2002
  • 유도등은 일정한 조도를 가지고 상용전원에 의하여 항상 점등되어 있어야 함으로 전력소비 및 광원 교체등 경제적 손실과 관리상의 문제가 있게 된다. 본 논문은 이제까지 광원으로 사용하고 있던 형광등이나 백열전구 대신에 소비전력이 적은 고효율 발광다이오드를 사용하여 전력소비의 절감과, 점검시의 문제점을 개선하기 위해 원격제어가 가능한 새로운 유도등회로를 제안하고 실험한 것이다. 그 결과 원격제어 스위치에 의한 유도등 점검을 제어각의 범위에서 쉽게 제어할 수 있었으며 반응시간은 600〔$\mu$s〕로 매우 빠르게 동작하였다. 또한 출력 상승시간(Rise time)과 하강고시간(Fall time)은 최대 200〔ns〕로 예민하게 반응하였다. 광원으로 고효율 발광다이오드를 사용함으로 광원을 교체해야 하는등의 문제를 제거하였으며 전력소비를 감소시킬 수 있음을 확인하였다.

Impact of Interface Charges on the Transient Characteristics of 4H-SiC DMOSFETs

  • Kang, Min-Seok;Bahng, Wook;Kim, Nam-Kyun;Ha, Jae-Geun;Koh, Jung-Hyuk;Koo, Sang-Mo
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.236-239
    • /
    • 2012
  • In this paper, we study the transient characteristics of 4H-SiC DMOSFETs with different interface charges to improve the turn-on rising time. A physics-based two-dimensional mixed device and circuit simulator was used to understand the relationship between the switching characteristics and the physical device structures. As the $SiO_2$/SiC interface charge increases, the current density is reduced and the switching time is increased, which is due primarily to the lowered channel mobility. The result of the switching performance is shown as a function of the gate-to-source capacitance and the channel resistance. The results show that the switching performance of the 4H-SiC DMOSFET is sensitive to the channel resistance that is affected by the interface charge variations, which suggests that it is essential to reduce the interface charge densities in order to improve the switching speed in 4H-SiC DMOSFETs.

듀얼채널을 적용한 반도체공정용 칠러의 실험적 연구 (An Experimental Study on Semiconductor Process Chiller for Dual Channel)

  • 차동안;권오경
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.760-766
    • /
    • 2010
  • Excessive heat occurs during semiconductor manufacturing process. Thus, precise control of temperature is required to maintain constant chamber-temperature and also wafer-temperature in the chamber. Compared to an industrial chiller, semiconductor chiller's power consumption is very high due to its continuous operation for a year. Considering the high power consumption, it is necessary to develop an energy efficient chiller by optimizing operation control. Therefore, in this study, a semiconductor chiller is experimentally investigated to suggest energy-saving direction by conducting load change, temperature rise and fall and control precision experiments. The experimental study shows the cooling capacity of dual-channel chiller rises over 30% comparing to the conventional chiller. The time and power consumption in the temperature rising experiment are 43 minutes and 8.4 kWh, respectively. The control precision is the same as ${\pm}1^{\circ}C$ at $0^{\circ}C$ in any cases. However, it appears that the dual channel's control precision improves to ${\pm}0.5^{\circ}C$ when the setting temperature is over $30^{\circ}C$.