• Title/Summary/Keyword: power-durability

Search Result 540, Processing Time 0.027 seconds

Harmonic Effects and Consideration in Power Converter and Component (전력변환장치의 고조파 영향 및 연구동향)

  • Cho Sung-Joon;Kim Tae-Wan;Woo Myung-Ho;Seo Kwang-Duk
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.467-470
    • /
    • 2001
  • Power electronic converters generate the harmonic voltage and current, and these harmonics have the harmful effects on the various components. For example, passive components such as capacitor and inductor, transformer, motor and other components are mainly affected in the power electronic system. Thus, the design and manufacturing of the power converters, which have the harmonic-free or mitigation strategies, are required. In particular, the lifetime and durability of these components are main requirement for enhancing the overall stability of the system. So, in this paper, the harmonics-related problems to the neighbouring components and mitigation research trends are presented.

  • PDF

Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition (연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석)

  • Kim, Kyungsoo;Yun, Jaeho
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.

The comparison of maximum output power of PV module by solar cell breakage (PV 모듈에서 셀의 파손에 따른 전기적 출력 특성 비교)

  • Lee, Jin-Seob;Kang, Gi-Hwan;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.9-10
    • /
    • 2007
  • In this paper, we investigated the effect of solar cell breakage on maximum output power of PV module. The test result using artificial light source didn't give any change in output power in case of crack near electrical ribbon. Also, there was a reduction in output power in case of increasing of crack area far from electrical ribbon. But, this experiment is under artificial light source test method. So, when such a PV module is outdoor for a long time, there would be problems on electrical output power and durability because of thermal aging phenomenon of solar cell breakage.

  • PDF

Development of a High-precision Small Ship Simulator Model Based on Hydrogen-electric Hybrid to Control an Integrated Thermal Management System (통합 열관리 시스템의 제어를 위한 수소-전기 하이브리드 기반 고정밀 소형 선박 시뮬레이터 모델 개발)

  • MINWOO AN;DAEIL HYUN;JAEYOUNG HAN
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.2
    • /
    • pp.230-239
    • /
    • 2024
  • Efforts are being made to replace ship diesel engines with electric propulsion motors in response to emission regulations. In particular, in the case of short-range small ships, research is being conducted to replace polymer electrolyte membrane fuel cells (PEMFC) with power sources. However, PEMFC has problems such as slow dynamic response characteristics and reduced durability at high temperatures. To solve this problem, a high-precision ship model was developed with power distribution and thermal management strategies applied, and through this, the required power, heat, and power characteristics of the propulsion system according to the ship's speed profile were analyzed.

A Convergency Study on the Gas Turbine Rotation Axis Temperature Sensor for Power Plants (발전소용 가스터빈 회전축 온도 센서 융합연구)

  • Lee, Jeongl-Ick;Na, Gi-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.293-298
    • /
    • 2019
  • The global market for temperature sensors for power plants is estimated at around 35 billion won, of which South Korea relies on imported products for more than 95 percent. This study is that a temperature measurement device for gas turbine rotators for power plants and can be applied to more than 800 of 100 MW gas turbine generators operating in Korea. This study has improved durability by changing the shape of the measuring part, structure of the connecting part, and material changes, and is a component technology applicable to other measuring devices such as humidity, gas and hydraulic pressure used in precision chemical process and plant export industry. As a result of this study, temperature sensors designed as three types of sensors for measuring the temperature of the gas turbine for power plants met Class 1 temperature accuracy in the range of 0℃ to 300℃, and improved durability significantly compared to similar products.

Development of a Duplexer Module for Remote Wireless Communication System of Guided Weapon System with Temperature-Insensitive Electrical Performances (온도변화에 둔감한 전기적 특성을 가지는 유도무기체계 원격무선통신시스템용 듀플렉서 모듈 개발)

  • Choi, Byung-Chang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.709-716
    • /
    • 2016
  • In this paper, A duplexer module with temperature-insensitive electrical characteristics was proposed for remote wireless communication system. Duplexer modules are required to have performances of low insertion loss, high isolation between transmitted band and received band, harmonic suppression as well as high power durability in the system for transmitting guided information to missile flying a free space on the ground. The proposed duplexer module are consist of transmission bandpass filter and receiving bandpass filter which are connected to common antenna port, planar coupler for output power monitoring and low pass filter for harmonic attenuation of power amplifier and coaxial cavity resonator. The material and dimensions of the resonator are determined for minimum frequency shift by temperature variation using 3D EM simulation. The measured results of the prototype showed a good agreement with the simulation results, and it should be well applied not only for guided weapon systems but also for any other communication systems such as remote radio head.

Operating Characteristics of Low Vacuum Pumps (저진공 펌프의 운전 특성)

  • 임종연;심우건;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.93-104
    • /
    • 2003
  • For evaluation of durability of low vacuum pumps, it is required to examine the performance and degradation of low vacuum pumps. Pump degradation may result from abnormalities associated with the performance in many areas of pump operation. The diagnostics method can be used to monitor the pump performance in the semi-conductor process line. Based on the mechanical defect of the pump, the dynamic response and reliability of the system for performance test, and the dynamic characteristics of the pump were experimentally assessed. The theoretical work rate for the compression process in the pump was calculated, and then the efficiency of the pump associated with the power consumption was evaluated. This analysis will be useful in detecting pump degradation with increasing the power consumption. To determine the predominant factors of pump degradation, it is important to evaluate the entire pumping system. We studied vibration, dynamic pressure, pumping speed, and power consumption of low vacuum pumps. Our results can be utilized for the future research on the evaluating technology of durability of low vacuum pumps.

Performance Improvement of High Performance Shrinkage Reducing Agent using Early Strength Improving Agent (조기강도 개선제를 활용한 고성능 수축저감제의 성능 개선)

  • Park, Jong-Pil;Jung, Yong-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.296-302
    • /
    • 2016
  • Studies aimed at reducing the occurrence of cracks by the shrinkage of concrete are in demand because the repair and reinforcement for cracks caused by declining concrete durability costs the user to maintain the concrete structure. In particular, in underground power facilities for power transmission, the cost is a heavy burden to repair and reinforce. For this reason, underground power facilities demanded effective methods for crack reduction at the engineering design step. This study, as a part of the development of shrinkage reducing agent for low shrinkage concrete on underground power facilities, investigated TEA to complement the shrinkage reducing agent to improve the early strength of concrete. In the case of TEA 3% as a shrinkage reducing agent, the early strength was improved significantly, and the shrinkage reducing effect was excellent. In addition, TEA 3.0 % and the shrinkage reducing agent 2.0 % showed excellent shrinkage property and compressive strength. On the other hand, more study of shrinkage reducing materials, including performance reviews on the shrinkage reducing materials with variable factors and type of materials, will be needed to generalize these results.

Design Technique for Improving the Durability of Top Coating for Thermal Barrier of Gas Turbine (가스터빈의 열차폐용 탑코팅의 내구성 향상 설계기술)

  • Koo, Jae-Mean;Seok, Chang-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • Thermal barrier coating (TBC) is used to protect the substrate and extend the operating life of the gas turbine for a power plant and an aircraft. The major cause of failure of such a coating is the spallation of coating, and it results from the thermal stress between top coating and bond coating. To improve the durability of TBC system, the dense vertical cracked (DVC) coating method to insert vertical cracks is applied to a gas turbine blade. In this study, a criterion for the design of vertical crack in the DVC coating was presented using the finite element analysis.

A Study on Endurance Improvement of Electrical Equipment according to Vibration Environment (진동환경에 따른 전기설비의 내구성 향상에 관한 연구)

  • Park, Keun-Seok;Shim, Jae-Myung;Lee, Dae-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1146-1151
    • /
    • 2014
  • The equipment in ships and railway vehicles are continuously exposed to vibration, and its durability is very important. Therefore, consumers require the verification of the performance of equipment via standardized tests under the given environments to improve and stabilize the performance. In this study, a durability improvement and stabilization plan was proposed, which included the exploratory vibration test, variable frequency test and endurance test for the electrical equipment according to the vibration environment. It is expected that this study results will improve the technological competitive power of the ship and railway-related manufacturers and contribute to the equipment development and export.