• 제목/요약/키워드: power system restoration

검색결과 167건 처리시간 0.023초

자체기동발전원으로서 BESS의 활용가능성 분석 및 용량 산정에 관한 연구 (A Study on the Feasibility Analysis and Capacity Estimation of BESS for Self-Starting Generators)

  • 김차년;유원근;김헌태;이흥재
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1119-1124
    • /
    • 2018
  • So far BESS(Battery Energy storage system) has been widely applied to power systems rapidly. Usually it has been used to regulate the renewable energy output and to adjust the power system frequency. In 2013, EPRI has reported a study of utilizing BESS to replace two black start generators of American Electric Power(AEP) that will be demolished. If the BESS can be used as a self-starting generator, it is possible to shorten the long-distance primary transmission line and shorten the restoration time because BESS is capable of the high-speed start and there is no restriction on the installation position. This paper presents a possibility of using BESS as a self-starting generator by using PSCAD/EMTDC in Korean power systems. Herein, the process to estimated the required capacity of BESS is also presented.

전기제동을 이용한 전동차의 혼합제동장치의 개발방향 (The Development for Blending Brake System of Electrical Multiple Unit used by Electric Brake)

  • 이우동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.155-157
    • /
    • 2008
  • An electric multiple unit(EMU) consists of car body, bogie and brake equipment which is directly related to safety and performance of the motorcar. The blending brake mixed an electric brake and a friction brake is to reduce the energy by applying the restoration energy caused when the motorcar is stopped to car lines and to curtail the maintenance cost by saving the friction brake use. We have developed the advanced EMU since 2004, based on the experiences on the standard EMU in 1999, and we develop the installation which minimizes the use rate of the friction air brake by maximizing the electric brake use in the existing blending brake. We could accomplish the goal by improving the motorcar's Performance and solving the restoration energy's deficit by the friction brake. Actually, when it comes to the test results of standard EMU, except the service brake, in most conditions, we use electric brake to meet the requirements of the necessary brake power, exclusive when the motorcar leaves and stops. Therefore, in this paper, we consider the design concept of motorcar's blending brakes and suggest the way to develop the blending brake using the electric brake maximumly, which is caused by adequately controling the electric brake and the restoration brake.

  • PDF

일부하 곡선을 이용한 배전계통 구간부하 관리방법 (A Section Load Management Method using Daily Load Curve in Distribution Systems)

  • 임성일
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.47-52
    • /
    • 2012
  • DAS(Distribution Automation System) is equipped with several software applications such as service restoration, loss minimization, and protective relay coordination. The software applications of DAS are very sensitive to the amount of section load being carried by a particular section of distribution lines. Moreover, each software application requires a different parameter of the section load according to its purpose. Therefore, This paper proposes a new section load management method using real-time measurement data of the distribution lines. In order to provide accurate data to DAS applications, this method considers section loads in terms of the relationship of power versus time. In order to establish that the proposed method is feasible, a performance-testing simulator was developed, and case studies were conducted for a modified real distribution network.

Study of Short-Circuit Currents Around Dĕtmarovice Power Station

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권3호
    • /
    • pp.117-124
    • /
    • 2014
  • The calculation of short-circuit currents is important for power systems operation and restoration, and for determining the means to protect human lives and properties. In this paper, a part of a power system network, around the D$\breve{e}$tmarovice power station in Czech Republic, was simulated by the well known program EMTP-ATPDraw (Electromagnetic Transients Program-Alternative Transient Program), and short-circuit currents and voltages were calculated at different points in the electric network and presented as a time function by the PlotXY program. Calculations were done just for phase-to-ground, and for the three-phase short-circuit at the Kun$\check{c}$ice substation. The results were important for determining the characteristics of the equipment required to withstand or break the short-circuit current; for this reason, the calculations were repeated using earth-fault resistances only for the case of busbar KUN shown in Figs. 5 and 6.

지역별 시송전선로 검토 및 검증방안에 관한 연구 (A study on the investigation and the verification method of the regional restorative transmission)

  • 이남호;송인준;조경보;곽노홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.187-189
    • /
    • 2003
  • Service restoration following a complete or partial collapse starts with reenergizing a transmission line from black-start generators. Voltage problems can arise from Ferranti effect as unloaded transmission line is reenergized and has to be required to consider it when KPX makes a restorative plan on the massive blackout. This paper presents the investigation of seven regional blackstart lines which are chosen by KPX restorative plan and suggests the verification method for the new designed line according to the system modification.

  • PDF

전문가 시스템에서의 system matrix를 이용한 정전 및 비정전구간 인식 (The Recognition of Energized & Deenergized System Using System Matrix in Expert system)

  • 함완균;추진부;김건중;심국진;조한형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.237-240
    • /
    • 1989
  • This paper deals with the expert system for power system recognition of energized and deenergized system using circuit breaker information. The basic idea is isolating the system with the system matrix representing the system configuration and the states of the circuit breakers. The knowledge base is composed of these isolated systems and decision rules. The isolated system with the sources is recognized as the energized system and the system without the source as the deenergized system. The rules use the system matrix and the the inference scheme is simplified in a great deal. Above all, the overall searching labor of the rules is independent on the system size and it is possible to expand into the real system and the real time restoration can be carried out easily. The expert system is written in PROLOG.

  • PDF

전력증폭기의 효율 및 선형성 개선을 위한 포락선 제거 및 복원 송신기 (Envelope Elimination and Restoration Transmitter for Efficiency and Linearity Improvement of Power Amplifier)

  • 조영균;김창완;박봉혁
    • 한국전자파학회논문지
    • /
    • 제26권3호
    • /
    • pp.292-299
    • /
    • 2015
  • 본 논문에서는 3-레벨 인코딩 기법을 적용하여 시스템의 효율과 선형성을 개선할 수 있는 새로운 구조의 EER 송신기를 제안하였다. 제안된 송신기는 첨두 전력 대 평균 전력비에 상관없이 동일한 크기의 신호만을 증폭하고, 채널대역 내의 양자화 노이즈를 감소시켜 높은 효율을 얻을 수 있으며, 포락선 신호와 위상 신호 간 시간 부정합 특성을 개선하여 높은 선형성을 가질 수 있도록 하였다. 130 nm CMOS 공정으로 제작된 송신기 칩은 8.5 dB의 첨두 전력 대 평균전력비를 갖는 LTE 20 MHz 신호에 대해 2.13 GHz의 반송주파수에서 3.7 %의 오류 벡터 크기와 37.5 dBc의 인접 채널 누설비 특성을 보인다.

음향 영상화기법을 이용한 발전용 밸브 유체누설평가 연구 (A Study on the Fluid Leakage Evaluation for Power Plant Valve Using Acoustic Imaging Technique)

  • 이상국;이선기;김대웅
    • 동력기계공학회지
    • /
    • 제15권1호
    • /
    • pp.18-23
    • /
    • 2011
  • Image processing has provided powerful techniques to extract from the acoustic signals the desired information on evaluation for leakage existence, leakage rate, and searching for leakage location, etc. The imagery NDE data available can add additional and significant dimension in nondestructive evaluation(NDE) information and thus for exploiting in applications. To extract such information the use of advanced image processing techniques is much needed. In recent years, there has been much increased use of acoustic signal image processing techniques in acoustic NDE. This approach will increase the efficiency of inspection procedures and reduce inspection time. In this paper we are concerned only with This paper is concerned mainly with the use of advanced image processing techniques in valve leakage detection and advanced image restoration and enhancement methods, which attempt to evaluate promptly by a visualization method the acoustic sources while detecting the valve leakage.

분산전원의 제어 특성을 고려한 마이크로그리드의 블랙 스타트 및 계통 동기화 전략 (Black Start and Synchronization of Microgrid Considering Distributed Generation Control)

  • 최진영;원동준
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.898-904
    • /
    • 2013
  • In order to minimize the damage from power outage, power system should be restored quickly. In this paper, a procedure for the restoration of microgrid is proposed. After elimination of the causes of power outage, a black start algorithm is executed by considering the characteristics of distributed generation control. After all resources have been recovered to the normal state, a grid reconnecting algorithm for stable operation in grid-connected mode is performed. In order to verify the proposed algorithm, low voltage microgrid is simulated using PSCAD/EMTDC.

돌극형 동기 발전기의 무효전력 공급 한계 해석 및 우선공급계통에의 적용 (Analysis of Reactive Power Capability for Salient Synchronous Generators, and its Application to Primary Restorative Systems)

  • 이흥재;박성민
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.14-17
    • /
    • 2007
  • Power system restoration following a massive blackout starts with re-energizing primary restorative transmission systems at first. The comparison of the TLCC(transmission line charging capacity) and the RPC(reactive power capability) of related black-start generator should be considered in this stage because overvoltage can be caused by self-excitation at the generator when the RPC is smaller than the TLCC. The RPC can be decided by two criteria. One is stator end core heating, and the other is steady state stability. RPC in steady state stability area has been found based on a synchronous reactance Xd. This paper presents RPC limit of salient pole machine which is different from that of non-salient pole machine in steady state stability area and shows derivation process about that.