• Title/Summary/Keyword: power system equivalent

Search Result 733, Processing Time 0.029 seconds

A Study on Photovoltaic/Wind/Diesel Hybrid Power System

  • Cho Jun-Seok;Gho Jae-Seok;Kim Kyung-Hyun;Choe Gyu-Ha;Kim Eung-Sang;Lee Chang-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.698-702
    • /
    • 2001
  • In this paper, to solve the defect of stand-alone type power system in a remote area, a hybrid power system with photovoltaic/wind/diesel generators is proposed. A hybrid power system has a power-balanced controller to equilibrate generation power with a given load demand and which is composed of common DC power system. To execute a power-balanced control, a hybrid power system is assumed that all of power generators have the characteristics of an equivalent current-source and load sharing control technique must be needed at the same time. So this paper describes the algorithm of interactive technique for design of a hybrid power system.

  • PDF

Converting a Lens to Its Equivalent as Referenced to Pupil Imaging (동의 결상을 기준으로 한 등가렌즈 변환에 대한 연구)

  • Bang, Hyun Jin;Lee, Jong Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.14-20
    • /
    • 2014
  • The equivalent of a thick lens is a lens which has the same power of refraction and paraxial imaging characteristics for a reference ray, but with a different axial thickness. In this study, thick lenses of an optical system were converted to their equivalent lenses referenced to pupil imaging. Aberration changes due to the lens conversion were compared to the general equivalent lens conversion referenced to object imaging.

S-Domain Equivalent System for Electromagnetic Transient Studies PART 2 : Frequency Dependent Network Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART 2 :주파수 의존 교류 시스템 등가)

  • Wang Yong P;Lee Hyun J;Chong Hyeng H;An Byung C;Kim Hae J
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.283-285
    • /
    • 2004
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. This paper presents the formulation for developing 1 & 2 port Frequency Dependent Network Equivalent (FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 & 2 Port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port (FDNE) developed with Norton Equivalent network.

  • PDF

A Study on Characteristics and Equivalent Circuit Model of Underwater Wireless Power Transfer System by Salinity (염도에 따른 수중 무선전력전송 시스템 특성 및 등가모델 연구)

  • Lee, Jeong-Geon;Kang, Wonshil;Ku, Hyunchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.851-856
    • /
    • 2018
  • In this study, we analyze the characteristics of wireless power transfer(WPT) based on magnetic resonance in an underwater environment and propose an equivalent model suitable for underwater WPT. The proposed underwater WPT equivalent model is constructed by expanding the free-space WPT T-model reflecting characteristics change according to media. Considering the water salinity, we propose a method to extract the parameters of the proposed model based on the S parameters. To verify the proposed model, a 6.78-MHz underwater WPT system was constructed and compared with the predicted power transfer efficiency of the model. As a result, it was confirmed that the proposed model predicts the variation of characteristics with an average error of less than 3 %.

Dynamic Equivalents of the KEPCO System for the Stability Analysis

  • Lee, Hanmin;Kwon, Sae-hyuk;Gilsoo Jang;Lee, Byongjun;Byunghun Chang
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.20-25
    • /
    • 2002
  • This paper deals with the development of dynamic equivalents of the Korea Electric Corporation (KEPCO) systems. Several coherency identification methods are studied in order to find a proper method to well represent the dynamic characteristics of the KEPCO system. Also, this paper presents the comparison of the detail and classical aggregation methods in terms of the dynamic and static characteristics of the system. The nonlinear time simulation of the developed KEPCO equivalent system and the original system is performed to illustrate the validity of the equivalent system.

Passive Current Sharing Characteristics of Multi-Phase Synchronous Buck Converter (다상 동기 벅 컨버터의 Passive Current Sharing 특성)

  • Kim, Jeong-Hoon;Cho, Kyung-Sig;Chung, Se-Kyo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.175-177
    • /
    • 2007
  • An analysis on a passive current sharing characteristics of a multi-phase synchronous buck converter is presented. The passive current sharing method is simple but its characteristics depend on the converter equivalent resistance and PWM uniformity. In this paper, the load sharing and power consumption of the passive current sharing system for the converter equivalent resistance and duty ratio inequalities are investigated through the simulation and experiment.

  • PDF

Development of the Low Cost Impedance Spectroscopy System for Modeling the Electrochemical Power Sources (전기화학적 전력 기기의 모델링을 위한 저가의 임피던스 분광 시스템의 개발)

  • Lee, Ju-Hyung;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.46-54
    • /
    • 2008
  • In this paper, a low-cost impedance spectroscopy system(LCISS) suitable for modeling the electrochemical power sources such as fuel cells, batteries and supercapacitors is designed and implemented. Since the developed LCISS is composed of simple sensor circuits, commercial data acquisition board and LabVIEW software, a graphic language with powerful HMI(Human-Machine Interface), it is expected ta be widely used in substitution of the expensive EIS instruments. In the proposed system, the digital lock-in amplifier is adopted to achieve the accurate measurements even in the presence of the high level of noises. The developed hardware and software is applied to measure the impedance spectrum of the Ballard Nexa 1.2kW proton exchange membrane fuel cell stack and an equivalent impedance model is proposed based on the measurement results. The validity of the proposed equivalent circuit and the developed system is proven by the measurement of the ac power losses of the PEM fuel celt stack by the ripple current.

Comparison of Seismic Responses of Seismically Isolated NPP Containment Structures using Equivalent Linear- and Nonlinear-Lead-Rubber Bearing Modeling (등가선형 및 비선형 납-고무받침 모델을 이용한 면진된 원전구조물의 지진응답의 비교)

  • Lee, Jin Hi;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • In order to perform a soil-isolation-structure interaction analysis of seismically isolated nuclear power plant (NPP) structures, the nonlinear behavior of a seismic isolation system may be converted to an equivalent linear model used in frequency domain analysis. Seismic responses for seismically isolated NPP containment structures subjected to a simple artificial acceleration history and different site class earthquakes are evaluated for the equivalent-linear and nonlinear models that have been applied to lead-rubber bearing (LRB) modeling. It can be observed that the maximum displacements of the equivalent linear model are larger than that of the nonlinear model. From the floor response spectrum analysis for the top of NPP containment structures, it can be observed that the spectral acceleration of an equivalent linear model at about 0.5 Hz frequency is about 2~3 times larger than that of a nonlinear model.

EMI Noise Source Reduction of Single-Ended Isolated Converters Using Secondary Resonance Technique

  • Chen, Zhangyong;Chen, Yong;Chen, Qiang;Jiang, Wei;Zhong, Rongqiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.403-412
    • /
    • 2019
  • Aiming at the problems of large dv/dt and di/dt in traditional single-ended converters and high electromagnetic interference (EMI) noise levels, a single-ended isolated converter using the secondary resonance technique is proposed in this paper. In the proposed converter, the voltage stress of the main power switch can be reduced and the voltage across the output diode is clamped to the output voltage when compared to the conventional flyback converter. In addition, the peak current stress through the main power switch can be decreased and zero current switching (ZCS) of the output diode can be achieved through the resonance technique. Moreover, the EMI noise coupling path and an equivalent model of the proposed converter topology are presented through the operational principle of the proposed converter. Analysis results indicate that the common mode (CM) EMI noise and the differential mode (DM) EMI noise of such a converter are deduced since the frequency spectra of the equivalent controlled voltage sources and controlled current source are decreased when compared with the traditional flyback converter. Furthermore, appropriate parameter selection of the resonant circuit network can increase the equivalent impedance in the EMI coupling path in the low frequency range, which further reduces the common mode interference. Finally, a simulation model and a 60W experimental prototype of the proposed converter are built and tested. Experimental results verify the theoretical analysis.

Development of 100 Kw Power Class Airborne Auxiliary Power Unit (100 Kw급 항공용 보조동력장치(APU) 개발)

  • Yang, Soo-Seok;Lee, Dae-Sung;Kim, Seung-Woo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.291-300
    • /
    • 1999
  • Currently under development is an airborne auxiliary power unit with 100 Kw equivalent power, which is composed of a centrifugal compressor, a reverse annular combustor, and a radial turbine. Air-foil bearings are used in this power unit to eliminate the oil supplying system, which can reduce the system complexity and weight. The high speed generator is adopted as an electric power generation and engine starting system, which can also eliminate the reduction gear system. Not only electric power but also pneumatic power is provided by bleeding the compressed air This power unit is aimed for the multi-purpose use such as a primary power unit In the army weapon system, an auxiliary power and environmental control unit in a next-generation tank, and a smoke generating unit.

  • PDF