Comparison of Seismic Responses of Seismically Isolated NPP Containment Structures using Equivalent Linear- and Nonlinear-Lead-Rubber Bearing Modeling  

Lee, Jin Hi (Department of Civil Engineering, Kangwon National University)
Song, Jong-Keol (Department of Civil Engineering, Kangwon National University)
Publication Information
Journal of the Earthquake Engineering Society of Korea / v.19, no.1, 2015 , pp. 1-11 More about this Journal
Abstract
In order to perform a soil-isolation-structure interaction analysis of seismically isolated nuclear power plant (NPP) structures, the nonlinear behavior of a seismic isolation system may be converted to an equivalent linear model used in frequency domain analysis. Seismic responses for seismically isolated NPP containment structures subjected to a simple artificial acceleration history and different site class earthquakes are evaluated for the equivalent-linear and nonlinear models that have been applied to lead-rubber bearing (LRB) modeling. It can be observed that the maximum displacements of the equivalent linear model are larger than that of the nonlinear model. From the floor response spectrum analysis for the top of NPP containment structures, it can be observed that the spectral acceleration of an equivalent linear model at about 0.5 Hz frequency is about 2~3 times larger than that of a nonlinear model.
Keywords
Equivalent linear model; nonlinear model; seismic isolation; lead-rubber bearing; nuclear power plant;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 PEER Strong Motion Database[Internet]. Berkeley, California Avle from: http://peer.berkeley.edu/smcat/sites.html.
2 Mazzoni S, McKenna F, Scott MH, Fenves GL. OpenSees: Open System of Earthquake Engineering Simulation, Pacific Earthquake Engineering Center, Univ. of Calif., Berkeley. (http://opensees.berkeley.edu), 2007.
3 Lysmer J, Ostadan F, Chin CC. A system for analysis of soil-structure interaction, SASSI 2000 theoretical manual. UC Berkeley; c1999.
4 FEMA P750. NEHRP Recommended Seismic Provisions for New Buildings and Other Structures. Washington D.C.: Federal Emergency Management Agency of the U.S. Department of Homeland Security; c2009.
5 U.S. Nuclear Regulatory Commission. Technical Considerations for Seismic Isolation of Nuclear Facilities(Draft). c2012.
6 Lee JH, Song JK, Kim GJ, Kim NY. Nonlinear Analysis of Seismically Isolated NPP Containment Structure considering Various Seismic Characteristics. Conference on Earthquake Engineering Society of Korea, EESK. c2014.
7 Lee JH, Song JK. Applicability Evaluation of Equivalent Linear Model for Isolated NPP Containment Structure. Conference on Korea Society of Civil Engineering, KSCE. c2013.
8 Kim HU. Evaluation of the Applicability of Existing Design Formula for Seismic Isolation to Nuclear Power Plants. Journal of Engineering Society of Korea. 2012;16(6):29-36.   DOI
9 Kim HU, Joo KH, NOH SH, Jung CG. Behavior Analysis od a Seismically Isolated NPP Structure by Varying Seismic Input Generation Method and Strong Ground Motion Duration. Journal of Engineering Society of Korea. 2013;17(4):187-195.   DOI
10 LEE JH, Kim JK, Hong KJ. Characteristics of Earthquake Responses of an Isolated Containment Building in Nuclear Power Plants According to Natural Frequency of Soil. Journal of Engineering Society of Korea. 2013;17(6):245-255.   DOI
11 Choi DH, LEE SH. Generation of Floor Response Spectra including Equipment-Structure Interaction in Frequency Domain. Journal of Engineering Society of Korea. 2005;9(6):13-19.   DOI
12 Kelly JM. Tension Buckling in Multilayer Elastomeric Bearings. journal of Engineering Mechanics. 2003;129(12):1363-1368.   DOI   ScienceOn
13 Providakis CP. Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations. Engineering Structures. 2008;30:1187-1198.   DOI   ScienceOn
14 Ricardo AM, Ragunath S, Kevin MK. Floor response spectra for light components mounted on regular moment-resisting frame structures. Engineering Structures. 2006;28:1927-1940.   DOI   ScienceOn
15 Dicleli M, Buddaram S. Equivalent linear analysis of seismic-isolated bridges subjected to near-fault ground motions with forward rupture directivity effect. Engineering Structures. 2007;29:21-32.   DOI   ScienceOn
16 Ryan KL, Kelly JM, Chopra AK. Nonlinear Model for Lead-Rubber Bearings Including Axial-Load Effects. journal of Engineering Mechanics. 2005;131(12):1270-1278.   DOI   ScienceOn