• 제목/요약/키워드: power intensity

검색결과 1,331건 처리시간 0.025초

주파수 출력 제어 최적화를 통한 고강도 집속 초음파 피부치료 시스템 개발 연구 (A Study on the Development of High-Intensity Focused Ultrasound Skin Treatment System Through Frequency Output Control Optimization)

  • 박종철;김민성
    • 한국멀티미디어학회논문지
    • /
    • 제25권8호
    • /
    • pp.1022-1037
    • /
    • 2022
  • It is important to develop a transducer that generates uniform output power through frequency control of the HIFU at 4 MHz frequency for the high intensity focused ultrasound (HIFU) skin diseases treatment. In this paper, a 4 MHz frequency band HIFU system for skin disease treatment was designed, manufactured and developed. In HIFU, even for the ultrasonic vibrator in the 4 MHz frequency band, the characteristics of the output power of the HIFU are different depending on the difference in the thickness of the PZT material. Through the development of a system amplifier, the sound output of the HIFU transducer was improved to more than 48 W and uniform output power control was possible. And, it is possible to control the output power even in a frequency band of 4.0 to 4.7 MHz, which is wider than 4.0 MHz, and shows the resonance frequency of the transducer. The maximum output power for each frequency was 49.969 W and the minimum value was 48.018 W. The maximum output power compared to the minimum output power is 49.969 W, which is uniform within 4.1%. It was confirmed that the output power of the HIFU through the amplifier can be uniformly controlled in the 4 MHz frequency band.

반무한보의 진동 인텐시티 계측에 대한 연구 (A Study on Structural Intensity Measurement of Semi-infinite Beam)

  • 이덕영;박성태
    • 소음진동
    • /
    • 제7권1호
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF

Evaluation of Light Intensity and Uniformity of LEDs for Protected Crop Production

  • Kim, MunJung;Choo, YounKug;Kim, YongJoo;Chung, SunOk
    • Agribusiness and Information Management
    • /
    • 제6권1호
    • /
    • pp.37-44
    • /
    • 2014
  • This study was conducted to evaluate light intensity and uniformity of two SMD (surface-mount device) type LEDs for protected crop production. A low-power (0.1 W) and a high-power (1 W) LEDs were selected and the intensity and uniformity was evaluated at different vertical (height) and horizontal (distance) intervals. When the horizontal interval of the LED bar was fixed, the light intensity increased and the uniformity decreased as the height decreased. At the 30~40 cm heights, 20~30% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. As the horizontal distance of the LED bars increased, while the uniformity increased as well, the light intensity decreased. At the distances of 6~10 cm, 17~23% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. When the LED bars were added to the sides, the light intensity and uniformity were generally improved. Results showed that the light intensity and uniformity depended on the height and interval of the LED bulbs; therefore, optimum arrangement for the crops interested should be determined through experiments.

상용전원 평행판전극 방전장치에서 수소플라스마의 가시광선스펙트럼 (Visible Light Spectrum of H2 Plasma Generated a Commercial Electric Power in the Parallel Plate Reactor)

  • 최운상;지택상;강성수
    • 한국안광학회지
    • /
    • 제4권1호
    • /
    • pp.15-20
    • /
    • 1999
  • 상용전원을 사용한 평행판전극 방전장치에서 수소플라스마로부터 방사되는 가시광선의 스펙트럼을 분광기로 조사하였다. 기체압력과 방전전력에 따라 수소플라스마로부터 방사되는 가시광선의 세기를 조사하고, 같은 조건에서 탐침으로 플라스마밀도를 측정하여 가시광선의 세기와 비교하였다. 측정결과, 가시광선의 세기는 플라스마의 밀도에 영향을 받으며, 플라스마 밀도는 기체압력과 방전전력에 영향받았다.

  • PDF

에너지절감을 위한 태양광발전설비 연계형 경관조명 전력제어시스템의 개발 (An Development of Landscape Lighting Power Control System with Solar Cell Generator Equipment for Energy Saving)

  • 김동완;박성원
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.364-371
    • /
    • 2010
  • In this paper, we propose the landscape lighting power control system with solar sell generator equipment for energy saving, and also which is included the landscape lighting power transformation device. The power transformation device can check inverse current in the power of the solar cell module and control the power of the battery. And we present the design of landscape lighting power control system. The power control system uses microprocessor with charging system and power transformation device. And also it can control the power of loads under consideration intensity of illumination. The landscape lighting loads are composed of LED(Lighting Emitting Diode) and HID(High Intensity Discharge)lamps. To evaluate property, we installed the solar cell array which generate three kilo watt power. Experimental results show that the proposed system can have stability and energy saving on the mixed configuration of electric loads with DC and AC lamps.

균열형상의 강체함유물을 포함하는 무한체에 대한 균열선단 부근의 응력분포와 응력세기계수 (Stress intensity factor and stress distribution near crack tip for infinite body containing regid inclusion with crack shape)

  • 이강용;김종성
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.680-683
    • /
    • 1998
  • In case of the infinite body containing a rigid inclusion with line crack shape, stress intensity factor is determined and the relation between stress intensity factor and stress distribution near a crack tip is developed. Also, the relation between stress intensity factor and Kolosoff stress function is developed. Finally, these results are compared with those that the crack surface is under no traction.

음향인텐시티법을 이용한 공조 덕트소음기의 감음성능평가방법에 관한 연구 (The Estimation of Sound Attenuation Caused by Duct Silencer Using Sound Intensity Method)

  • 김석홍;손장열;오재응;김여식
    • 한국음향학회지
    • /
    • 제6권2호
    • /
    • pp.54-61
    • /
    • 1987
  • 실험실이 아닌 일반음장에서 음향인텐시티법을 이용하여 공조덕트 소기기의 감음성능 평가방법을 검토하였다. 음향인델시티법에 의한 감음량 측정치는 음압법에 의한 측정치보다 이논치와 비교적 잘 일치하였으며, 음향인텐시티법은 음압법에 비하여 음장조건에 따른 영향을 비교적 적게 받는 것으로 나타났다.

  • PDF

국내 전력산업의 탄소배출 변화요인 분석 : 로그평균디비지아지수를 이용한 수요와 공급 측면 분석 (Decomposition Analysis of Carbon Emission in Korea Electricity Industry : Utilizing the Logarithmic Mean Divisia Index Method to the Demand and the Supply Side)

  • 김규남;김강석;김연배
    • 자원ㆍ환경경제연구
    • /
    • 제19권2호
    • /
    • pp.243-282
    • /
    • 2010
  • 본 연구는 1991년~2007년간 우리나라 전력산업의 탄소배출에 미치는 요인들과 영향의 정도를 전력 수요측면과 공급측면으로 나누어 요인분해분석을 수행하였다. 전력수요측면에서는 전력사용의 효율성 향상이 배출 감소에 주된 영향을 미치는 반면, 전력을 소비하는 산업의 구조 변화는 오히려 배출을 증가시키는데 기여했음을 확인하였다. 공급측면에서는 탄소배출에 미치는 주요 요인으로 연료혼합, 화력발전효율, 발전구조의 변화 등이 있었으며 분석 결과 전력수요의 증가와 화력발전의 구조 변화가 탄소배출을 증가시키는 주요한 요인으로 작용한 반면 연료효율성은 향상되어 배출을 감소시키는 역할을 한 것으로 나타났다. 이로써 전력산업의 온실가스 감축을 위해 수요차원에서는 전력사용의 효율성을 향상시키고 공급차원에서는 화력발전을 대체하면서 발전 및 배출 효율성을 향상시킬 수 있는 정책이 마련되어야 한다는 것을 알 수 있었다.

  • PDF

태양광발전설비와 연계한 지능형 경관조명 전력제어 및 모니터링 시스템의 개발 (Development of Intelligent Landscape Lighting Power Control and Monitoring System with Solar Cell Generator Equipment)

  • 김동완;박성원;김형수
    • 전기학회논문지P
    • /
    • 제60권2호
    • /
    • pp.99-104
    • /
    • 2011
  • In this paper, the intelligent landscape lighting power control and monitoring system with solar sell generator equipment is proposed. The first, the intelligent landscape lighting power controller is designed using the fuzzy logic control method. And the fuzzy logic controller is used to save power consumption for various reference intensity of the illumination. The second, the GUI monitoring system is presented. It has control and display faculty. And the practical experiment device is used to evaluate the performance criteria of the proposed intelligent landscape lighting power control system with the solar cell power generation equipment. From the experiment results, we present the property of proposed fuzzy controller such as steady state error, the tracking and power consumption characteristic for the reference intensity of illumination. And also we show the superiority of power control as well as the characteristic of GUI monitoring system in the proposed system.

Oligomerized polyphenols in lychee fruit extract supplements may improve high-intensity exercise performance in male athletes: a pilot study

  • Kawamura, Aki;Hashimoto, Shun;Suzuki, Miho;Ueno, Hiromasa;Sugita, Masaaki
    • 운동영양학회지
    • /
    • 제25권3호
    • /
    • pp.8-15
    • /
    • 2021
  • [Purpose] Excessive reactive oxygen species (ROS) induced by prolonged high-intensity exercise can cause structural and functional damage. Antioxidant polyphenol supplementation, which reduces ROS levels, may improve high-intensity exercise performance. We evaluated the effect of lychee fruit extract, which contains high levels of low-molecular-weight oligomerized polyphenols, on high-intensity exercise performance. [Methods] Ten male athletes were included in an open-label trial that consisted of control and intervention phases, with a 7-day washout period between phases. The participants were administered oligomerized lychee fruit extract for seven days, whereas no intervention was given in the control phase. High-intensity intermittent exercise and the Wingate test were performed. The power output, blood lactate levels, reactive oxygen metabolite levels, biological antioxidant potential, heart rate, and rate of perceived exertion were measured. [Results] The average power output was significantly higher in the intervention phase than in the control phase (P < 0.01), while the change in blood lactate levels was significantly lower in the intervention phase than in the control phase (P < 0.05). The average heart rate was significantly higher in the intervention phase than in the control phase (P < 0.05), without changing the rate of perceived exertion. Although there was no difference in reactive oxygen metabolite levels between the phase, the change in biological antioxidant potential was larger in the intervention phase than in the control phase (P = 0.06). The Wingate test showed no significant differences between the phase. [Conclusion] Short-term loading with oligomerized lychee fruit extract may increase performance during high-intensity intermittent exercise by improving metabolism.