• Title/Summary/Keyword: power intensity

Search Result 1,331, Processing Time 0.029 seconds

A Study on the Development of High-Intensity Focused Ultrasound Skin Treatment System Through Frequency Output Control Optimization (주파수 출력 제어 최적화를 통한 고강도 집속 초음파 피부치료 시스템 개발 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1022-1037
    • /
    • 2022
  • It is important to develop a transducer that generates uniform output power through frequency control of the HIFU at 4 MHz frequency for the high intensity focused ultrasound (HIFU) skin diseases treatment. In this paper, a 4 MHz frequency band HIFU system for skin disease treatment was designed, manufactured and developed. In HIFU, even for the ultrasonic vibrator in the 4 MHz frequency band, the characteristics of the output power of the HIFU are different depending on the difference in the thickness of the PZT material. Through the development of a system amplifier, the sound output of the HIFU transducer was improved to more than 48 W and uniform output power control was possible. And, it is possible to control the output power even in a frequency band of 4.0 to 4.7 MHz, which is wider than 4.0 MHz, and shows the resonance frequency of the transducer. The maximum output power for each frequency was 49.969 W and the minimum value was 48.018 W. The maximum output power compared to the minimum output power is 49.969 W, which is uniform within 4.1%. It was confirmed that the output power of the HIFU through the amplifier can be uniformly controlled in the 4 MHz frequency band.

A Study on Structural Intensity Measurement of Semi-infinite Beam (반무한보의 진동 인텐시티 계측에 대한 연구)

  • 이덕영;박성태
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF

Evaluation of Light Intensity and Uniformity of LEDs for Protected Crop Production

  • Kim, MunJung;Choo, YounKug;Kim, YongJoo;Chung, SunOk
    • Agribusiness and Information Management
    • /
    • v.6 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • This study was conducted to evaluate light intensity and uniformity of two SMD (surface-mount device) type LEDs for protected crop production. A low-power (0.1 W) and a high-power (1 W) LEDs were selected and the intensity and uniformity was evaluated at different vertical (height) and horizontal (distance) intervals. When the horizontal interval of the LED bar was fixed, the light intensity increased and the uniformity decreased as the height decreased. At the 30~40 cm heights, 20~30% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. As the horizontal distance of the LED bars increased, while the uniformity increased as well, the light intensity decreased. At the distances of 6~10 cm, 17~23% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. When the LED bars were added to the sides, the light intensity and uniformity were generally improved. Results showed that the light intensity and uniformity depended on the height and interval of the LED bulbs; therefore, optimum arrangement for the crops interested should be determined through experiments.

Visible Light Spectrum of H2 Plasma Generated a Commercial Electric Power in the Parallel Plate Reactor (상용전원 평행판전극 방전장치에서 수소플라스마의 가시광선스펙트럼)

  • Choi, Woon Sang;Ji, Taek Sang;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.15-20
    • /
    • 1999
  • Visible light spectrum emitted from $H_2$ plasma in the parallel plate reactor using a commercial electric power are investigated by optical emission spectroscopy. Intensity of visible light is measured as a function of $H_2$ pressure and discharging power, and the intensity is compared with plasma density measured with the probe. As a result, the intensity is affected by plasma density and the plasma density is controlled the $H_2$ pressure and the discharging power.

  • PDF

An Development of Landscape Lighting Power Control System with Solar Cell Generator Equipment for Energy Saving (에너지절감을 위한 태양광발전설비 연계형 경관조명 전력제어시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.364-371
    • /
    • 2010
  • In this paper, we propose the landscape lighting power control system with solar sell generator equipment for energy saving, and also which is included the landscape lighting power transformation device. The power transformation device can check inverse current in the power of the solar cell module and control the power of the battery. And we present the design of landscape lighting power control system. The power control system uses microprocessor with charging system and power transformation device. And also it can control the power of loads under consideration intensity of illumination. The landscape lighting loads are composed of LED(Lighting Emitting Diode) and HID(High Intensity Discharge)lamps. To evaluate property, we installed the solar cell array which generate three kilo watt power. Experimental results show that the proposed system can have stability and energy saving on the mixed configuration of electric loads with DC and AC lamps.

Stress intensity factor and stress distribution near crack tip for infinite body containing regid inclusion with crack shape (균열형상의 강체함유물을 포함하는 무한체에 대한 균열선단 부근의 응력분포와 응력세기계수)

  • Lee, Kang-Young;Kim, Jong-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.680-683
    • /
    • 1998
  • In case of the infinite body containing a rigid inclusion with line crack shape, stress intensity factor is determined and the relation between stress intensity factor and stress distribution near a crack tip is developed. Also, the relation between stress intensity factor and Kolosoff stress function is developed. Finally, these results are compared with those that the crack surface is under no traction.

The Estimation of Sound Attenuation Caused by Duct Silencer Using Sound Intensity Method (음향인텐시티법을 이용한 공조 덕트소음기의 감음성능평가방법에 관한 연구)

  • Kim, Seok-Hong;Son, Jang-Yeol;O, Jae-Eung;Kim, Yeo-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.54-61
    • /
    • 1987
  • This paper is to suggest the test method of sound attenuation caused by absorptive duct silencer using sound intensity method in field. In order to estimate sound attenuation, sound power being radiated from sound power source and duct exhaust terminal was measured by the sound pressure method and sound intensity method in semianechoic and common room. The results of the measured sound attenuation values by sound intensity method are more similar to those of theoretical calculation than those by the sound pressure method. In addition, sound intensity method is much less influenced by sound field condition or continuous background noise than the sound pressure method.

  • PDF

Decomposition Analysis of Carbon Emission in Korea Electricity Industry : Utilizing the Logarithmic Mean Divisia Index Method to the Demand and the Supply Side (국내 전력산업의 탄소배출 변화요인 분석 : 로그평균디비지아지수를 이용한 수요와 공급 측면 분석)

  • Kim, Kyunam;Kim, Kangseok;Kim, Yeonbae
    • Environmental and Resource Economics Review
    • /
    • v.19 no.2
    • /
    • pp.243-282
    • /
    • 2010
  • In this paper, we analyze the components and trends of carbon emissions using the Logarithmic Mean Divisia Index decomposition method in Korean electricity industry during the period 1991~2007. In the demand side, carbon emissions are affected by electricity intensity and structural shift and especially electricity intensity is identified as the major factor which has lead carbon emissions decreasing. In the supply side, the result in variations of carbon emission for electric power generation depends on the influences of fossil fuel mix, fuel intensity, generation mix and so on. As a result fuel intensity is the most negative effect on both carbon emission intensity and the amount of carbon emission while the change of generation mix has a positive effect on increasing carbon emissions. And to conclude it needs to make the strategic policies to improve electricity intensity in the demand and to rise emission efficiency as well as to substitute thermal power generation in supply side.

  • PDF

Development of Intelligent Landscape Lighting Power Control and Monitoring System with Solar Cell Generator Equipment (태양광발전설비와 연계한 지능형 경관조명 전력제어 및 모니터링 시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won;Kim, Hyung-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.2
    • /
    • pp.99-104
    • /
    • 2011
  • In this paper, the intelligent landscape lighting power control and monitoring system with solar sell generator equipment is proposed. The first, the intelligent landscape lighting power controller is designed using the fuzzy logic control method. And the fuzzy logic controller is used to save power consumption for various reference intensity of the illumination. The second, the GUI monitoring system is presented. It has control and display faculty. And the practical experiment device is used to evaluate the performance criteria of the proposed intelligent landscape lighting power control system with the solar cell power generation equipment. From the experiment results, we present the property of proposed fuzzy controller such as steady state error, the tracking and power consumption characteristic for the reference intensity of illumination. And also we show the superiority of power control as well as the characteristic of GUI monitoring system in the proposed system.

Oligomerized polyphenols in lychee fruit extract supplements may improve high-intensity exercise performance in male athletes: a pilot study

  • Kawamura, Aki;Hashimoto, Shun;Suzuki, Miho;Ueno, Hiromasa;Sugita, Masaaki
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.3
    • /
    • pp.8-15
    • /
    • 2021
  • [Purpose] Excessive reactive oxygen species (ROS) induced by prolonged high-intensity exercise can cause structural and functional damage. Antioxidant polyphenol supplementation, which reduces ROS levels, may improve high-intensity exercise performance. We evaluated the effect of lychee fruit extract, which contains high levels of low-molecular-weight oligomerized polyphenols, on high-intensity exercise performance. [Methods] Ten male athletes were included in an open-label trial that consisted of control and intervention phases, with a 7-day washout period between phases. The participants were administered oligomerized lychee fruit extract for seven days, whereas no intervention was given in the control phase. High-intensity intermittent exercise and the Wingate test were performed. The power output, blood lactate levels, reactive oxygen metabolite levels, biological antioxidant potential, heart rate, and rate of perceived exertion were measured. [Results] The average power output was significantly higher in the intervention phase than in the control phase (P < 0.01), while the change in blood lactate levels was significantly lower in the intervention phase than in the control phase (P < 0.05). The average heart rate was significantly higher in the intervention phase than in the control phase (P < 0.05), without changing the rate of perceived exertion. Although there was no difference in reactive oxygen metabolite levels between the phase, the change in biological antioxidant potential was larger in the intervention phase than in the control phase (P = 0.06). The Wingate test showed no significant differences between the phase. [Conclusion] Short-term loading with oligomerized lychee fruit extract may increase performance during high-intensity intermittent exercise by improving metabolism.