• Title/Summary/Keyword: power fluctuation

Search Result 603, Processing Time 0.027 seconds

A 3.3V 8-bit 500MSPS Nyquist CMOS A/D Converter Based on an Interpolation Architecture (Interpolation 기법을 이용한 3.3V 8-bit 500MSPS Nyquist CMOS A/D Converter의 설계)

  • 김상규;송민규
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.8
    • /
    • pp.67-74
    • /
    • 2004
  • In this paper, a 3.3V 8-bit 500MSPS based on an interpolation architecture CMOS A/D converter is designed. In order to overcome the problems of high speed operation, a novel pre-amplifier, a circuit for the Reference Fluctuation, and an Averaging Resistor are proposed. The proposed Interpolation A/D Converter consists of Track & Hold, four resistive ladders with 256 taps, 128 comparators, and digital blocks. The proposed A/D Converter is based on 0.35um 2-poly 4-metal N-well CMOS technology. The A/D Converter dissipates 440 mW at a 3.3 Volt single power supply and occupies a chip area of 2250um x 3080um.

A case Study for Protection Relay System of small Cogeneration intertie (소형 열병합 발전기 계통연계 운전시의 적용 보호지침 개선 제안)

  • Yoon, K.K.;Kim, K.S.;Hyun, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.227-230
    • /
    • 2004
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. For Con-Gen users, the several protection relays are recommended to install at the user's main incoming panel by the guide lines and/or instructions of the interconnected utility Then user's main CB(Circuit Breaker) have the chance to be tripped by some of this recommended relays and users have to undergo the unexpected blackout. So the circuit breaker trip schemes targeted to trip with these protection relays are reconsidered and the study result is hereunder proposed.

  • PDF

Fluctuations in the Exhaust System -Single Cylinder Misfire- (배기계 압력 변동을 이용한 가솔린 기관의 실화 검출 -단수 실린더 실화-)

  • Sim, K.S.;Bok, J.H.;Kim, S.W.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.210-217
    • /
    • 1998
  • This paper describes the method for detection of the misfired cylinder using the pressure fluctuations occurred in the exhaust system on an MPI gasoline engine. If misfire is occurred in the cylinder of the gasoline engine, the power of engine gets lost, the fuel consumption and the exhaust emission are increased and the vibration is caused by unsteady torque. Therefore early detection and correction of misfire play a very important role in the proper performance and the exhaust emission. This paper suggests method of misfire detection which affect engine performance. The method is a comparison of average pressure index during the displacement period. Experimental results showed that the method using the pressure fluctuations in the exhaust system is proven to be effective in the detection of misfire on gasoline engine regardless loads and revolutions of the engine. In addition, this method, using the pressure fluctuations in exhaust system is easier than other methods and is not a need of additional reconstruction of engine.

  • PDF

Study on Memristive Characteristics in Electronic Devices Based on Vanadium Dioxide Thin Films Using 966nm Laser Pulses (966nm 레이저 펄스를 이용한 바나듐 이산화물 박막 기반 전자 소자에서의 멤리스터 특성에 관한 연구)

  • Kim, Jihoon;Lee, Yong Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.59-65
    • /
    • 2015
  • By harnessing the thermal hysteresis behavior of vanadium dioxide($VO_2$), we demonstrated multi-resistance states in a two-terminal electronic device based on a $VO_2$ thin film by using a 966nm infrared laser diode as an excitation light source for resistance modulation. Before stimulating the device using 966nm laser pulses, the thermal hysteresis behavior of the device resistance was measured by using a temperature chamber. After that, the $VO_2$ device was thermally biased at ${\sim}71.6^{\circ}C$ so that its temperature fell into the thermal hysteresis region of the device resistance. Six multi-states of the device resistance could be obtained in the fabricated $VO_2$ device by five successive laser pulses with equal 10ms duration and increasing power. Each resistance states were maintained while the temperature bias was applied. And, the resistance fluctuation level was within 2.2% of the stabilized resistance and decreased down to less than 0.9% of the stabilized resistance 5s after the illumination.

Eye Pattern Characteristic Based Active Stabilization Method for Direct Delection Receiver in Differential Phase Shift Key System (차동 위상 변조 전송 시스템에서 수신 신호 눈열림 특성을 이용한 직접 검출 수신단 최적화 및 안정화 제어 연구)

  • Jang, Youn-Seon;Park, Heuk;Kim, Kwang-Joon
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.313-318
    • /
    • 2005
  • We propose an active stabilization method for the receiver of NRZ-DPSK transmission. The 1-bit delayed Mach-Zehlder interferometer is thermally controlled to maintain the largest DC component power ratio between the constructive and destructive output ports, for the optimum transmission condition. This method is very cost effective since no additional components are required. Experimental results show that the proposed scheme guarantees error free performance even when there was ~ 1 GHz optical carrier frequency fluctuation in 10 Gbps transmission.

Harmonic Noise Evaluation Method for Home Appliance based on Sensory Evaluation (소비자 감성 평가에 의한 고조파 소음의 평가 방법)

  • Lee, Jin-Kyung;Jeoung, Jeoung-Kyo;Lee, Jea-Won;Joo, Jae-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.439-442
    • /
    • 2005
  • Generally, noise from a home appliance has been measured by overall sound pressure level or sound power level, dB. Customers evaluation, however, of this noise should be depend on the only overall level but also the sensory feeling, annoyance, unpleasure and so on. Moreover, in this sensory evaluation, irregular, time-varying and uneven sounds which are difficult to describe itself by overall level are more affectable. Unfortunately however the formal evaluation method for this kinds of noise is not determined yet. In this research, the evaluation method for harmonic noise, which is a major noise from home appliance and one of the unmeasurable sounds by overall level, is proposed to evaluate its acceptability based on the consumer's sense of hearing. The proposed approach could be applied to the other sound, which acoustical characteristics are similar to the tonal noise.

  • PDF

Evaluation of Goundwater Flow Pattern at the Site of Crystalline Rock using Time Series and Factor Analyses (시계열분석과 요인분석에 의한 결정질 암반의 지하수 유동 평가)

  • Lee, Jeong-Hwan;Jung, Haeryong;Yun, Si-Tae;Kim, Jee-Yeon;Cho, Sung-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.4
    • /
    • pp.12-22
    • /
    • 2014
  • This study evaluated the pattern of groundwater fluctuation in cyrstalline rock using time series and factor analyses. From the results, groundwater level for the 18 wells was classified into 4 types reflecting the hydrogeological properties and rainfall event. Type 1 (DB1-5, DB1-6, DB2-2, KB-10, KB-13) was significantly influenced by groundwater flow through water-conducting features, whereas type 2 (DB1-3, DB1-7, KB-1~KB-3, KB-7, KB-11, KB-14, KB-15) was affected by minor fracture network as well as rainfall event. Type 3 (DB1-1, DB1-2) was mainly influenced by surface infiltration of rainfall event. Type 4 (DB1-8, KB-9) was reflected by the irregular variation of groundwater level caused by anisotropy and heterogeneity of crystalline rock.

A Novel Harmonic Compensation Technique for the Grid-Connected Inverters (계통연계 인버터를 위한 새로운 고조파 보상법)

  • Ashraf, Muhammad Noman;Khan, Reyyan Ahmad;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.71-73
    • /
    • 2019
  • The output current of the Grid Connected Inverter (GCI) can be polluted with harmonics mainly due to i) dead time in switches, ii) non-linearity of switches, iii) grid harmonics, and iv) DC link fluctuation. Therefore, it is essential to design the robust Harmonic Compensation (HC) technique for the improvement of output current quality and fulfill the IEEE 1547 Total harmonics Distortion (THD) limit i.e. <5%. The conventional harmonic techniques often are complex in implementation due to their i) additional hardware needs, ii) complex structure, iii) difficulty in tuning of parameters, iv) current controller compatibility issues, and v) higher computational burden. In this paper, to eliminate the harmonics from the GCI output current, a novel Digital Lock-In Amplifier (DLA) based harmonic detection is proposed. The advantage of DLA is that it extracts the harmonic information accurately, which is further compensated by means of PI controller in feed forward manner. Moreover, the proposed HC method does not require additional hardware and it works with any current controller reference frame. To show the effectiveness of the proposed HC method a 5kW GCI prototype built in laboratory. The output current THD is achieved less than 5% even with 10% load, which is verified by simulation and experiment.

  • PDF

Prediction of Pressure Fluctuations on Hammerhead Vehicle at Transonic Speeds Using CFD and Semi-empirical Formula Considering Spatial Distribution (CFD와 공간분포를 고려한 반경험식을 이용한 해머헤드 발사체의 천음속 압력섭동 예측)

  • Kim, Younghwa;Nam, Hyunjae;Kim, June Mo;Sun, Chul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.6
    • /
    • pp.457-464
    • /
    • 2021
  • To analyze the buffet phenomenon that causes serious vibration loads on a satellite launch vehicle, the pressure fluctuations on a hammerhead launch vehicle at transonic speeds are predicted by coupling CFD analysis and semi-empirical methods. From the RANS simulation, shock oscillation region, separation region, and separation reattachment region are identified, and the boundary layer thickness, the displacement thickness, and flow properties at boundary layer edge are calculated. The pressure fluctuations and power spectra on the hammerhead fairing are predicted by coupling RANS results and semi-empirical methods considering spatial distribution, and compared with the experimental data.

Fluctuating Pressure Coefficients Distributions for Elliptical Dome Roof (타원형 돔 지붕의 변동풍압특성)

  • Lee, Jong-Ho;Cheon, Dong-Jin;Kim, Yong-Chul;Park, Sang-Woo;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.63-71
    • /
    • 2020
  • The fluctuating wind pressure of the low rise ratio(f/D=0.1) for the elliptical dome roof was analyzed to compare it with the previous studies of circular dome roofs. Wind tunnel test were conducted on a total of 10 wind directions from 0° to 90° while changing wall height-span ratios(H/D=0.1-0.5). For this, meanCP, rmsCP and wind pressure spectrum were analyzed. The analysis result leads to find differences in the shape of the spectra in the spanwise direction and leeward of the elliptical dome according to the wind direction variations of the elliptical dome roof.