• 제목/요약/키워드: power current

검색결과 13,804건 처리시간 0.042초

울돌목 조류발전의 연안물리적 관점에서의 고찰 (Coastal-physical cceanographic aspects in relation to the tidal current power generation in the Uldolmok)

  • 염기대;이광수;박진순;강석구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.516-519
    • /
    • 2005
  • The pilot tidal current power plant is to be constructed at the Uldolmok between Chindo and Haenam, during next year. and extensive coastal engineering research works have been carried out. In this paper we describes some observation results of the tide and tidal current. as well as modeling work in order to investigate the tide and tidal current regime change in relation to the tidal current power plant (TCPP) construction. The special modeling skill in order to consider the turbine operation in the TCPP is developed and applied to the estimation for the flow regime change by the simple layout of the tidal current power plant.

  • PDF

반주기 이후 동작 하이브리드 초전도 전류제한기와 보호기기 협조 분석 (Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter)

  • 김진석;임성훈;김재철;최종수
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1832-1837
    • /
    • 2011
  • The fault current has increased due to the large power demand in power distribution system and network distribution system. To protect the power system effectively from the increased fault current, the superconducting fault current limiter (SFCL) has been notified. However, the conventional SFCL has some problems such as cost, operation, recovery, loss. To solve some problems, the hybrid superconducting fault current limiter using the fast switch was proposed. However, hybrid SFCL also has a problem that is protection coordination in power distribution system with hybrid SFCL. In this paper, the fault current limiting characteristics of hybrid SFCL with first half cycle non-limiting operation according to the fault angle, the resistance of superconducting element, and the magnitude of Current Limit Resistor (CLR) which are the components of hybrid SFCL were analyzed through the experiments.

울돌목 조류발전의 연안물리적 관점에서의 고찰 (Coastal-physical cceanographic aspects in relation to the tidal current power generation in the Uldolmok)

  • 강석구;염기대;이광수;박진순
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.73-78
    • /
    • 2005
  • The pilot tidal current power plant is to be constructed at the Uldolmok between Chindo and Haenam, during next year, and extensive coastal engineering research works have been carried out. In this paper we describes some observation results of the tide and tidal current, as well as modeling work in order to investigate the tide and tidal current regime change In relation to the tidal current power plant [TCPP] construction. The special modeling skill in order to consider the turbine operation in the TCPP is developed and applied to the estimation for the flow regime change by the simple layout of the tidal current power plant.

  • PDF

Time-Delay Effects on DC Characteristics of Peak Current Controlled Power LED Drivers

  • Jung, Young-Seok;Kim, Marn-Go
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.715-722
    • /
    • 2012
  • New discrete time domain models for the peak current controlled (PCC) power LED drivers in continuous conduction mode include for the first time the effects of the time delay in the pulse-width-modulator. Realistic amounts of time delay are found to have significant effects on the average output LED current and on the critical inductor value at the boundary between the two conduction modes. Especially, the time delay can provide an accurate LED current for the PCC buck converter with a wide input voltage. The models can also predict the critical inductor value at the mode boundary as functions of the input voltage and the time delay. The overshoot of the peak inductor current due to the time delay results in the increase of the average output current and the reduction of the critical inductor value at the mode boundary in all converters. Experimental results are presented for the PCC buck LED driver with constant-frequency controller.

Improved Control Strategy Based on Space Vectors for Suppressing Grid-Side Current Harmonics in Three-Phase Current Source Rectifiers with a Hybrid Switch

  • Xu, Yan;Lu, Guang-Xiang;Jiang, Li-Jie;Yi, Gui-Ping
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.497-503
    • /
    • 2015
  • This paper analyses the harmonic pollution to power grids caused by several high-power rectifiers, summarizes the requirements for rectifiers in suppressing grid-side current harmonics and optimizes a new-type of current source PWM rectifier with a hybrid switch. The rectifier with a hybrid switch boasts significant current characteristics and cost advantages in the high-power area. To further enhance the working frequency of the current source rectifier with a hybrid switch for suppressing grid-side harmonics and reducing the inductance size, this paper proposes an optimal control strategy based on space vector. It also verifies that the optimal control strategy based on space vector can reduce the total harmonic distortion of the grid-side current of the rectifier with a hybrid switch via circuit simulation and experimental results.

펄스파워 전류 측정용 센서 개발 및 특성 평가 (Development of Current Sensor for Pulsed Power and its Characteristics Evaluation)

  • 한상보
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.230-234
    • /
    • 2019
  • 본 논문은 펄스파워 동작시의 수백 ns의 대전류를 측정하기 위한 전류 센서의 개발과 특성평가 결과에 대하여 논하였다. 개발된 전류 센서는 펄스 파워 동작시 전류에 의해 발생되는 자속으로부터 유기기전력을 측정하도록 특별히 설계하였다. 개발 된 전류 센서의 출력 특성은 상업용 센서의 출력 특성과 매우 일치하였으며, 개발 된 센서의 출력 전압 검량선을 이용하여 빠른 펄스 파워의 실제 전류를 쉽게 검출 할 수 있음을 보였다. 따라서, 본 연구에서 개발 된 전류 센서는 실제적인 펄스파워 시스템에 적용할 수 있음을 확인하였다.

불평형 전압 조건에서 스위칭 소자의 전류 용량과 순환전류를 고려한 HVDC-MMC 제어기법 (Control of HVDC-MMC Considering the Switching Device's Current Capacity and Circulating Current under Unbalanced Voltage Conditions)

  • 문지우;배득우;박정우;강대욱;유동욱;김장목
    • 전력전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.270-278
    • /
    • 2013
  • This paper proposes a control method for high voltage direct current(HVDC) with modular multilevel converter (MMC) under unbalanced voltage conditions considering the submodule(SM)'s current capacity and circulating current. It is aimed to propose a control method in which the current peak value does not exceed the maximum value of HVDC-MMC by considering the current capacity of the SM under unbalance voltage conditions. And it analyzes the effect of the unbalanced voltage on circulating currents in MMC and then proposes a control method considering each component of circulating currents under unbalanced voltages. The effectiveness of the proposed controlling method is verified through simulation results using PSCAD/EMTDC.

아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법 (The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control)

  • 김석희;최병민;박종후;전희종
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.133-138
    • /
    • 2014
  • This paper proposes a low power-loss averaging current mode control using a resistor and bypass switch. Generally, current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. An analog-circuited bypass driver is implemented and used along with an average-circuit mode controller. The bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 50[W] prototype average current mode boost converter has been implemented for the experimental verification.

고전압 용량성 결합 플라즈마 시스템의 개선된 전압 파형 출력을 위한 펄스 전류 발생장치 회로 (Current Source Type Pulse Generator with Improved Output Voltage Waveform for High Voltage Capacitively Coupled Plasma System)

  • 채범석;민주화;서용석;김현배
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.153-160
    • /
    • 2019
  • This study proposes a current source-type pulse generator to improve output voltage and current waveforms under a capacitively coupled plasma (CCP) system. The proposed circuit comprises two parallel-connected current source-type converters. These converters can satisfy the required output waveforms of plasma processing. The parallel-connected converters operate without reverse current fault by applying a time-delay control technique. Conventional voltage source converters based on pulse power supply exhibit drawbacks in short-circuit current, and problems occur when they are applied to a CCP system. The proposed pulse power supply based on a current source converter fundamentally solves the short-circuit current problem. Therefore, this topology can improve the voltage and current accuracy of a CCP system.