• 제목/요약/키워드: power configuration

검색결과 1,613건 처리시간 0.026초

Study on the Fire Hazard and Risk Analysis Derived from the Plant Configuration Change During the Shutdown Period at Nuclear Power Plants

  • Jee Moon-Hak;Hong Sung-Yull;Sung Chang-Kyung;Jung Hyun-Jong
    • Nuclear Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.547-555
    • /
    • 2003
  • Fire hazard and risk analysis at Nuclear Power Plants is implemented on the basis of the normal operational configuration. This steady configuration, however, can be changed due to the temporary displacement of equipment, electric cable and irregular movement of workers through the fire compartments when the on-line maintenance is processed during the power operation mode or the scheduled outage mode for the refueling. With the consequence of this configuration change, the fire analysis condition and the evaluation result will be different from those that were analyzed based on the steady configuration. In this context, at this paper, the general items for the reassessment are categorized when the configuration has changed. The contemporary zone models for the detail fire analysis are also illustrated for their application for each classified condition.

원전 형상기준선 적용방안에 관한 연구 (A Study on the Application Method of Configuration Baseline for Nuclear Power Plant)

  • 박유진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.199-200
    • /
    • 2017
  • The Configuration Management(CM) of Nuclear Power Plant(NPP) is an activity that maintains consistency among the design requirement, facility configuration information and physical configuration. It is a systematic approach to performing various engineering tasks such as change management by identifying, documenting the characteristics of plant Structures, Systems and Component(SSC). The first activity that should be performed the configuration baseline setting at the start of project. The configuration baseline of the NPP construction phase is the status of the SSC of the plant at a specified process and time, and the actual configuration changes depending on the condition of plant. In this paper, I have studied the current status of configuration baseline used in the software industry and general plant industry, method of establishment for the configuration baseline which was first applied to the construction of NPP.

  • PDF

A GRADED MINIMAL FREE RESOLUTION OF THE m-TH ORDER SYMBOLIC POWER OF A STAR CONFIGURATION IN ℙn

  • Park, Jung Pil;Shin, Yong-Su
    • 대한수학회지
    • /
    • 제58권2호
    • /
    • pp.283-308
    • /
    • 2021
  • In [30] the author finds a graded minimal free resolution of the 2-nd order symbolic power of a star configuration in ℙn of any codimension r. In this paper, we find that of any m-th order symbolic power of a star configuration in ℙn of codimension 2, which generalizes the result of Galetto, Geramita, Shin, and Van Tuyl in [15, Theorem 5.3]. Furthermore, we extend it to the m-th order symbolic power of a star configuration in ℙn of any codimension r for m = 3, 4, which also generalizes the result of Biermann et al. in [1, Corollaries 4.6 and 5.7]. We also suggest how to find a graded minimal free resolution of the m-th order symbolic power of a star configuration in ℙn of any codimension r for m ≥ 5.

최소 컷셋법에 의한 화력발전소 기동전원의 신뢰도 예측에 관한 연구 (A Study on the Reliability Evaluation of Start-up Power Supply in Fossil Power Plant by Minimal Cut-Set Method)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.358-364
    • /
    • 1999
  • The auxiliary transformers or start-up/stand-by transformer(s) are installed against the start-up and shut-down of generator and emergency status in fossil power plant. The on-site power supply configuration using these transformers must be determined, considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and ecfonomy of plant. The auxiliary or start-up/stand-by power supply configuration has been determined considering only safety requirements and construction cost until now in Korea. This paper presents general theorems for the reliability estimation and proposes 2-unit based 4 alternatives for the start-up power supply stystem of 500㎿ standardized fossil power plant. The reliability and unavailability of equipment, system and configuration are determined using minimal cut-set methodology. The optimized plan of 4 alternatives is determined based on this ultimate reliability and unavailability.

  • PDF

Buck-Boost Interleaved Inverter Configuration for Multiple-Load Induction Cooking Application

  • Sharath Kumar, P.;Vishwanathan, N.;Bhagwan, K. Murthy
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.271-279
    • /
    • 2015
  • Induction cooking application with multiple loads need high power inverters and appropriate control techniques. This paper proposes an inverter configuration with buck-boost converter for multiple load induction cooking application with independent control of each load. It uses one half-bridge for each load. For a given dc supply of $V_{DC}$, one more $V_{DC}$ is derived using buck-boost converter giving $2V_{DC}$ as the input to each half-bridge inverter. Series resonant loads are connected between the centre point of $2V_{DC}$ and each half-bridge. The output voltage across each load is like that of a full-bridge inverter. In the proposed configuration, half of the output power is supplied to each load directly from the source and remaining half of the output power is supplied to each load through buck-boost converter. With buck-boost converter, each half-bridge inverter output power is increased to a full-bridge inverter output power level. Each half-bridge is operated with constant and same switching frequency with asymmetrical duty cycle (ADC) control technique. By ADC, output power of each load is independently controlled. This configuration also offers reduced component count. The proposed inverter configuration is simulated and experimentally verified with two loads. Simulation and experimental results are in good agreement. This configuration can be extended to multiple loads.

A GRADED MINIMAL FREE RESOLUTION OF THE 2ND ORDER SYMBOLIC POWER OF THE IDEAL OF A STAR CONFIGURATION IN ℙn

  • Shin, Yong-Su
    • 대한수학회지
    • /
    • 제56권1호
    • /
    • pp.169-181
    • /
    • 2019
  • In [9], Geramita, Harbourne, and Migliore find a graded minimal free resolution of the 2nd order symbolic power of the ideal of a linear star configuration in ${\mathbb{P}}^n$ n of any codimension r. In [8], Geramita, Galetto, Shin, and Van Tuyl extend the result on a general star configuration in ${\mathbb{P}}^n$ but for codimension 2. In this paper, we find a graded minimal free resolution of the 2nd order symbolic power of the ideal of a general star configuration in ${\mathbb{P}}^n$ of any codimension r using a matroid configuration in [10]. This generalizes both the result on a linear star configuration in ${\mathbb{P}}^n$ of codimension r in [9] and the result on a general star configuration in ${\mathbb{P}}^n$ of codimension 2 in [8].

고 입력전압 전력변환 응용에 적합한 입력직렬-출력병렬 컨버터 시스템 (Input Series-Output Parallel Connected Converter System for High Voltage Power Conversion Applications)

  • 김정원;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.455-459
    • /
    • 1998
  • In this paper input Series-Output Parallel connected converter configuration for high voltage power conversion applications is proposed and a control method to solve the problems of Input Series-Output Paralles connected converter configuration is introduced. In this configuration snubber circuit or voltage balancing controller that is necessary for the series connection of switching devices is not needed. The effectiveness of this proposed configuration is verified by simulation.

  • PDF

운용성, 경제성에 기초한 철도 배전계통 구성방안 (A Study on the Configuration Schemes for Railway Power Distribution System on the basis of power Quality, reliability, and economic aspects)

  • 오광해;김주락;이한민;창상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1254-1257
    • /
    • 2002
  • This study presents the configuration schemes for railway power distribution system. The possible alternatives are derived and reviewed on the basis of power quality, reliability, and economic aspects. As a result, a few of configuration schemes are recommended for railway power distribution system

  • PDF

FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구 (A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

형상관리와 국내외 원전 동향 (Configuration Management and Domestic and International nuclear power plant trends)

  • 고민혁;이대성
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.351-353
    • /
    • 2022
  • 국내와 국외를 통틀어서 현재까지 원전사고가 수차례 있었고 이로 인한 크고 작은 피해가 있었다. 해외는 이러한 사고를 줄이기 위해서 형상관리라는 기술을 도입하여 원전 운영에 대한 안전성과 신뢰성을 향상 시켜왔다. 본 논문에서는 형상관리에 관한 기본적인 정보와 국외 원전의 형상관리 도입 성공사례들을 통해서 국내에 적용 가능한 기술적 부분을 확인하고 이를 국내 원전에 맞게 보완하여 새로이 적용할 수 있는지를 알아본다.

  • PDF