• 제목/요약/키워드: portable generator

검색결과 62건 처리시간 0.025초

Low Cost and Portable Parahydrogen Generator for the PHIP

  • Kwon, Soonmo;Min, Sein;Chae, Heelim;Namgoong, Sung Keon;Jeong, Keunhong
    • 한국자기공명학회논문지
    • /
    • 제21권4호
    • /
    • pp.126-130
    • /
    • 2017
  • In the developed NMR hyperpolarization techniques, Parahydrogen-Induced Polarization (PHIP) technique is widely utilized to overcome the low sensitivity of the NMR/MRI. Parahydrogen generator is essential to produce high spin order of parahydrogen molecule. Commercial parahydrogen generator is well developed with user-friendly systems. However, it has drawbacks of long preparation time (~ 2h including cooling down time of 1h) and high cost (~ 200 million won) for the commercial setup. We designed a simple and portable parahydrogen generating system with low cost (~ 2 million won), which produce polarization in less than 1 min. With the designed parahydrogen generator, we successfully performed the PHIP with Wilkinson's catalyst on styrene. This study will broaden the parahydrogen based polarization transfer study on many researchers by providing the simple portable and low cost parahydrogen generator.

이동형 치과 X선 발생장치의 공간선량 분포 (Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment)

  • 한경순;안성민
    • 치위생과학회지
    • /
    • 제15권3호
    • /
    • pp.254-258
    • /
    • 2015
  • 치과병의원에서 사용하고 있는 이동형 치과 X선 발생장치를 이용하여 두경부 마네킹에 X선을 조사할 때 주변의 공간선량을 측정하고, 동일한 방법으로 고정형 X선 발생장치에 적용하여 측정된 공간선량을 상호 비교하며, 더불어 기기 및 위치별 공간선량을 비교 분석한 결과는 다음과 같다. 이동형 X선 발생장치의 평균 공간선량은 $37.51{\mu}Sv$로 고정형 X선 발생장치의 $10.77{\mu}Sv$보다 매우 높았다(p<0.001). 이동형 X선 발생장치의 기기별 공간선량은 $17.77{\mu}Sv$부터 $68.90{\mu}Sv$까지 큰 차이를 나타냈다(p<0.05). 위치별로는 직전 위치가 $54.14{\mu}Sv$로 가장 높았고, 직우 위치가 $13.60{\mu}Sv$로 가장 낮았으며, 직좌와 직후 위치는 $42.12{\mu}Sv$, $40.18{\mu}Sv$로 유사하였다(p<0.01). 이상의 결과를 통해 이동용 치과 X선 발생장치는 이동 불가능한 환자만을 대상으로 제한적으로 시행하여야 하며, 반드시 환자와 술자 모두 납 방어복을 착용하여 방사선 피폭을 최소화해야 할 것이다.

이동식 ICG를 이용한 과도접지임피던스 측정 시스템 구축 (Installation of Measuring System for the Transient Ground Impedances using Portable Impulse Current Generator)

  • 이태형;조성철;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.199-201
    • /
    • 2007
  • This paper presents the installation of measuring system for the transient behaviors of grounding system impedances using portable impulse current generator. The measuring system is controller, with controller, power supply, impulse current generator and data aquisition system. In the evaluation of the impulse response in a ground electrode, the step response is calculated based on the ratio of the voltage and current observed.

  • PDF

휴대용 압력파 발생장치를 사용한 단일관로에서의 누수탐지 연구 (Study of leak detection in a pipeline system using a portable pressure wave generator)

  • 고동원;이정섭;김진원;김상현
    • 상하수도학회지
    • /
    • 제34권2호
    • /
    • pp.139-147
    • /
    • 2020
  • This paper suggests a nonlinear pressure consideration scheme through an unsteady pipe network analyzer for leakage detection with a portable pressure wave generator. In order to evaluate the performance of a proposal scheme, linear input pattern has been simulated and experiments had been carried out under both no leakage and one leakage conditions in a reservoir-pipeline-valve system. This method using portable pressure wave generator showed that a leakage can be detected from a reflection where a leakage is originated through time domain analysis. Meaningful similarity in pressure response between nonlinear input pattern and experimental results were found both no leakage and a leakage conditions.

Optimal Design and Performance Analysis of Permanent Magnet Assisted Synchronous Reluctance Portable Generators

  • Baek, Jeihoon;Kwak, Sangshin;Toliyat, Hamid A.
    • Journal of Magnetics
    • /
    • 제18권1호
    • /
    • pp.65-73
    • /
    • 2013
  • In this paper, design and performance analysis of robust and inexpensive permanent magnet-assisted synchronous reluctance generators (PMa-SynRG) for tactical and commercial generator sets is studied. More specifically, the optimal design approach is investigated for minimizing volume and maximizing performance for the portable generator. In order to find optimized PMa-SynRG, stator winding configurations and rotor structures are analyzed using the lumped parameter model (LPM). After comparisons of stator windings and rotor structure by LPM, the selected stator winding and rotor structure are optimized using a differential evolution strategy (DES). Finally, output performances are verified by finite element analysis (FEA) and experimental tests. This design process is developed for the optimized design of PMa-SynRG to achieve minimum magnet and machine volume as well as maximum efficiency simultaneously.

터보 방식으로 구동되는 마이크로 파워 시스템의 회전체 동역학적 특성에 관한 연구 (A Study on the Rotordynamic Characteristics of the Micro Turbo Generator)

  • 류근;이용복;이병수;김창호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.109-115
    • /
    • 2004
  • The micro turbo generator is new portable power source based on the Brayton cycle, which consists of a compressor, a turbine, a generator, and a combustion chamber. In this paper, the thermodynamic analysis was performed to find the required condition for hundreds watts power in the micro turbo generator, and also the rotordynamic stability was predicted using the numerical analysis of air foil bearings which support the micro turbo generator. By experimental works, the rotordynamic stability of the micro turbo generator with foil bearings was verified. While various transient dynamic situation, the micro turbo generator had stable performances. From the result, it was demonstrated that air foil bearings could be adapted to the micro turbo generator as a excellent lubrication element.

  • PDF

열차속도에 따른 GPS형 열차접근경보기의 경보안정성 분석 (A study on alarm stability using GPS type portable-alarm-system by train speed.)

  • 권기진;온정근;심재복;최영하
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1272-1277
    • /
    • 2004
  • GPS type portable-alarm-system is composed of satellite receiving equipment, signal transmission equipment, etc. Time errors occur because of the processing methods of the satellite receiving equipment and signal generator, the positional error of GPS itself, etc. With the recent rise of train speed, it becomes very important to secure the stability of portable-alarm-system from time errors, The present study estimated errors caused by the structure of portable-alarm-system, GPS errors. etc., and verified them. In addition, it examined the effects of such errors on portable-alarm-system according to train speed.

  • PDF

A Study on Optimization of Compact High-voltage Generator Based on Magnetic-core Tesla Transformer

  • Jeong, Young-Kyung;Youn, Dong-Gi;Lee, Moon-Qee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1349-1354
    • /
    • 2014
  • This paper presents a compact and portable high-voltage generator based on magnetic-core Tesla transformer for driving an UWB high power electromagnetic source. In order to optimize the performance of the high-voltage generator, a novel open-loop cylindrical magnetic-core adopting the quad-division lamination structure is proposed and manufactured. The designed high-voltage generator using the proposed magnetic core has a battery-powered operation and compact size of $280mm{\times}150mm$ in length and diameter, respectively. The high-voltage generator can produce a voltage pulse waveform with peak amplitude of 450 kV, a rise time of 1.5 ns, and pulse duration of 2.5 ns at the 800 V input voltage.

50Wh급 배터리 충전을 위한 휴대용 자가발전시스템 연구 (A Study of a Manual Generator System for 50Wh Battery Charge)

  • 이지영;구대현;한충규
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.223-230
    • /
    • 2012
  • This paper deals with an design of axial flux electric machine which is a key element for a compact size in a portable and manual generator system. It is expected that the generator system with an axial flux electric machine is more light and has higher efficiency than other types of generator systems. And it is used the soft magnetic composite core instead of silicon steel core in the axial flux electric machine for more compact size. The weight and efficiency of the generator system are the main keys to select the value of design variables. In this paper, the overall design process to meet the design goals, and the design results are presented with experiment results.