• 제목/요약/키워드: porcelain

검색결과 938건 처리시간 0.029초

Effects of core characters and veneering technique on biaxial flexural strength in porcelain fused to metal and porcelain veneered zirconia

  • Oh, Ju-Won;Song, Kwang-Yeob;Ahn, Seung-Geun;Park, Ju-Mi;Lee, Min-Ho;Seo, Jae-Min
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.349-357
    • /
    • 2015
  • PURPOSE. The purpose of this study was to assess the impact of the core materials, thickness and fabrication methods of veneering porcelain on prosthesis fracture in the porcelain fused to metal and the porcelain veneered zirconia. MATERIALS AND METHODS. Forty nickel-chrome alloy cores and 40 zirconia cores were made. Half of each core group was 0.5 mm-in thickness and the other half was 1.0 mm-in thickness. Thus, there were four groups with 20 cores/group. Each group was divided into two subgroups with two different veneering methods (conventional powder/liquid layering technique and the heat-pressing technique). Tensile strength was measured using the biaxial flexural strength test based on the ISO standard 6872:2008 and Weibull analysis was conducted. Factors influencing fracture strength were analyzed through three-way ANOVA (${\alpha}{\leq}.05$) and the influence of core thickness and veneering method in each core materials was assessed using two-way ANOVA (${\alpha}{\leq}.05$). RESULTS. The biaxial flexural strength test showed that the fabrication method of veneering porcelain has the largest impact on the fracture strength followed by the core thickness and the core material. In the metal groups, both the core thickness and the fabrication method of the veneering porcelain significantly influenced on the fracture strength, while only the fabrication method affected the fracture strength in the zirconia groups. CONCLUSION. The fabrication method is more influential to the strength of a prosthesis compared to the core character determined by material and thickness of the core.

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

도재소부용 18K 금합금의 미량원소의 첨가에 따른 물리적 성질의 변화에 관한 연구 (A Study on Change of Physical Property in Porcelain Fused to 18K Gold Alloy by Small Additional Elements)

  • 이기대
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.31-37
    • /
    • 2008
  • A variety of the porcelain fused to gold(PFG) have been developed to which porcelain can be fused. PFG alloys developed for this purposed have a high melting point and do not discolor when combined with porcelain. The design of the compositions of PFG is very important to esthetic restorative materials applying to porcelain. The purpose of this study is on the change of physical and mechanical characteristics in PFG 18K alloy by the small additional elements. Principal results are as follows. The high Au alloy containing 18Karat gold contents is respectively Au(75%), Pd(10%), Pt(4%), Ag(4%), In(2%), Sn(2%), Cu(2%), Ti(1%). These alloys are composed mainly of gold, platinum, silver and palladium with a few percent of the additional elements. By the addition of small amounts of elements such as In, Sn, Ti, the fine grain castings are produced in gold alloy and the small addition of platinum is very effective in increasing of hardness and strength. These gold alloys are representative of the changes to be expected as a result of heat treatment. These changes in strength and hardness values are sufficient to demonstrate a significant difference in performance between a as-casted and a heat-treated. These alloys have mechanical properties characteristics of Type and Type gold alloys. These alloys are useful to porcelain-metal restorations and dental laboratory. Also the porcelain fused to metal(PFM) alloys containing gold are commonly use for dental purposes in dental laboratory.

  • PDF

금속 소부 도재관의 경우 인접면에서 접촉점의 위치가 도재 파절에 미치는 영향에 관한 연구 (A Study on effect that position of contact area at adjacent side has on fractures of porcelains in case of porcelain fused to metal crown)

  • 김용원
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.173-180
    • /
    • 2007
  • There was a great problem about the deposition between materials of a different kind at the beginnings of the introduction of porcelains, however, thereafter the deposition efficiency was settlded to the sufficient level of all user thanks to effort to have studied by many scholars and clinical authorities. But in a clinical process, as the difference of designs has an effect on fractures of porcelains, this researcher divided them into 4 groups of A: 1 mm, B: 2 mm, C: 3 mm, and D: 4 mm, and made 40 pieces to each 10 as the test samples to consider a length axis of tooth for studies in accordance with a position of a finishing line to meet between porcelain and metal at the contact point at the adjacent side to a metal porcelain. The sample materials are those to be use at the open market and the test samples wer completed by the same manufacturing technique to that of existent metal porcelain tube. s a result of the strength test on fractures, the average value is as in the following, A: 1 mm - 8.5bar, B: 2 mm - 10.5bar, C: 3 mm - 14.3bar, and D: 4 mm - 15.0bar. In case of the metal porcelain tube, the more faraway to process parts of metal and porcelain from the contact point of adjacent side has the stronger strength of fractures, Accordingly, the research shows that it had better to keep off more than 3 to consider a ledngth axis of tooth.

  • PDF

치과도재용(齒科陶材用) 합금(合金)과 도재간(陶材間)의 잔류응력(殘溜應力) 및 결합강도(結合强度)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE RESIDUAL STRESS AND BOND STRENGTH OF CERAMO-METAL SYSTEM)

  • 김기진;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.67-84
    • /
    • 1991
  • This study was carried out to investiagate the residual stress caused by the mismatch of thermal expansion and the bond failure resistance of alloy-porcelain specimens. The thermal expansions of alloys and porcelains were measured by using a straight push-rod dilatometer. Porcelain glass transition temperatures, thermal expansion coefficients, and thermal compatibility indices were derived from length-versus-temperature curves. Strain gauges were used to experimentally determine the Young's moduli of porcelains, the residual stresses of porcelain surface, and tensile bond strengths of the specimens of simulated porcelain metal crown. The obtained results were as follows: 1. The coefficients of thermal expansion for alloys were the minimum of $13.53\mu/^{\circ}C$ and the maximum of $20.11\mu/^{\circ}C$ in the range of $100\sim600^{\circ}C$ and those for porcelains were the minimum of $7.72\mu/^{\circ}C$ and the maximum of $31.24\mu/^{\circ}C$ in the range of $100\sim500^{\circ}C$. 2. The glass transition temperature of porcelains exhibited the same value without my relation to the healing rate, and the thermal disharmony of porcelain and alloy was more affected by porcelains than by the alloys. 3. The Young's moduli of body porcelains were larger than those of opaque porcelains(P<0.01) 4. It seemed that the residual stresses of porcelain surfaces in the porcelainalloy systems were more affected by porcelains than by alleys. 5. The bond strengths of the procelain-base metal alloy systems were larger than those of the porcelain-precious metal alloy systems. The fracture strengths of porcelain surfaces showed significant difference between porcelains (P<0.05).

  • PDF

Porcelain laminate veneer의 수복 (Porcelain Laminate Veneer Restoration)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제28권2호
    • /
    • pp.191-200
    • /
    • 2012
  • 도재 라미네이트 비니어(Porcelain laminate veneer, PLV)는 아주 얇은 도재를 치면에 직접 적용시키는 술식으로 전치부 심미 개선을 목적으로 전부피개관 대신에 보존적으로 사용될 수 있다. 그러나 PLV의 성공을 높이기 위해 치질 삭제량을 적절히 조절하는 것은 어려울 뿐만 아니라, 각 치아마다 법랑질 두께가 다양하고 증령에 따라 치관구조 역시 변화하기 때문에 치아 삭제시 주의가 필요하다. 즉 치아 순면을 따라 일관되게 삭제하는 기존의 방법을 이용할 경우 법랑질이 얇아진 부위에서는 상아질이 노출될 위험이 있다. 이를 방지하기 위해 다양한 치아 삭제 방법들이 소개되고 있는데 진단 납형제작을 통한 실리콘 인덱스와 아크릴릭 레진 mock-up을 이용한 방법은 최종적인 수복물의 형태에 기초하여 치아를 삭제할 수 있어 불필요한 법랑질 삭제를 줄이고 상아질 노출을 최소화할 수 있다. 또한 비정상적으로 배열된 치아 삭제시에도 적절한 삭제량 결정이 어려워 삭제량이 과도해지거나 부족해지기 쉬운데, 최종 보철물의 형태를 기준으로 실리콘 인덱스를 제작하면 이를 방지할 수 있다.

Evaluation of efficiency of manual polishing over autoglazed and overglazed porcelain and its effect on plaque accumulation

  • Haralur, Satheesh B.
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.179-186
    • /
    • 2012
  • PURPOSE. The aim of this study was to evaluate the efficiency of manual polishing over autoglazed and overglazed porcelain and their effect on plaque accumulation. MATERIALS AND METHODS. Thirty-six porcelain discs were fabricated out of which 18 each was subjected for autoglazing and overglazing. Half surface of the discs was left intact; the remaining half was roughened with medium grit diamond bur. Roughened surfaces were repolished by porcelain polishing kits (Shofu, DFS, Eve). All the surfaces were evaluated by the perthometer and SEM. Six discs from each sample were placed in human volunteer's mouth for 72 hours to evaluate the plaque accumulation. Acquired data was subjected to ANOVA comparative evaluation. RESULTS. Roughened surfaces had average roughness value of $2.88{\pm}0.1935{\mu}m$. The repolished surfaces by porcelain correction kits Shofu, DFS and Eve, average roughness value reduced to $0.6250{\pm}0.1036$, $0.9192{\pm}0.0953$, $0.9017{\pm}0.1305$ respectively. Autoglazed and overglazed surfaces showed the mean roughness value (Ra) of $0.4217{\pm}0.0685$, $0.3450{\pm}0.0729$. SEM study showed the improved surfaces when subjected for polishing. Plaque accumulation percentage was the highest on roughened surface ($93.83{\pm}6.2552%$), followed by porcelain discs polished by commercial kits. Autoglazed surfaces found to be the best surfaces with the least plaque accumulation ($0.5237{\pm}0.4209%$). CONCLUSION. All the polishing kits used in the study reduced the average roughness by approximately 77%. Corrected porcelain surfaces should ideally be reglazed, alternatively, polish the surfaces before final cementation.

하부구조물 및 두께에 따른 치과 수복용 세라믹의 색조에 대한 분광측색분석 (Spectrophotometic analysis of the influence of substrate on the color of dental ceramics)

  • 송영균
    • 구강회복응용과학지
    • /
    • 제31권2호
    • /
    • pp.96-103
    • /
    • 2015
  • 목적: 본 연구는 하부구조물과 축성된 도재의 두께 차이에 따른 색상의 차이를 비교연구하여 보고자 함이다. 연구 재료 및 방법: 금속하부구조물과 완전도재 하부구조물위에 0.5 mm 간격으로 도재의 두께를 다르게 축성을 한 후에 spectrophotometer를 이용하여, 색상을 측정하였다. 이후 측색값과 ${\Delta}E*$값을 통계학적으로 비교 분석하였다. 결과: 도재의 두께가 증가함에 따라 명도가 감소하였다(P < 0.05). 세라믹 하부구조물의 경우 축성된 도재의 두께가 증가할수록 $a^*$값이 감소였으나(P < 0.05), 두께는 $b^*$값에 유의한 영향을 주지 않았다. 도재 두께 차이가 0.5 mm 이하일 경우 ${\Delta}E*$값이 1이하였다. 결론: 하부구조물의 종류에 따라 차이가 있으나, 도재의 두께가 색상에 영향을 주는 요소이며, 두께에 따른 색조 변화 양상의 인지를 통하여, 임상에서 도재 두께변화를 이용한 색상조절에 도움이 될 것이라 사료된다.

2종의 측색기에 의한 도재 색조 재현의 정확성 비교 (Comparison on accuracy of porcelain color reproducibility using two colorimeters)

  • 이태일;안진수;김영수;신상완
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.348-355
    • /
    • 2009
  • 연구 목적: ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan)와 Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany)의 도재색조 재현의 정확성을 비교연구하여 보고자 함이다. 연구 재료 및 방법: ShadeEye-Ncc dental chroma meter와 Shadepilot$^{TM}$ system을 사용하여 Vitapan 3D Master shade guide의 2M2와 3M2 shade tap.을 측색하고, 이 자료를 통하여 shade guide tap. 형태로 도재시편을 제작한다. 시편제작 시 사용하는 porcelain system은 ShadeEye-Ncc dental chroma meter는 Vintage Halo Porcelain system을, Shadepilot$^{TM}$ system은 VitaOmega900 Porcelain system을 사용한다. 모델인 shade tap.과 제작된 도재시편을 spectrophotometer로 측색하고, 그 결과를 토대로하여 ${\Delta}E$를 계산하여, 두 측색기의 정확성을 비교검증하였다. 결과: 1. Shadepilot$^{TM}$ system이 ShadeEye-Ncc dental chroma meter에 비하여 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 2. 모델인 Shade tap.의 shade에 따라서 도재색조 재현성에 차이를 나타내었다. 2M2 shade tap.에 비하여 3M2 shade tap.에서 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 3. 두 측색기 모두에서 제작된 도재시편의 ${\Delta}E$가 평균4.44-6.14로 육안으로 구분 가능한 정도의 색조차이를 보였다. 결론: Shadepilot$^{TM}$ system이 비교적 더 정확한 도재색조 재현성을 나타낸다고 할 수 있으며, ShadeEye-Ncc dental chroma meter를 사용할 때는 치아 전체의 여러부분에서 측색을 하여 정확성을 높이는 것이 필요하리라 생각된다.

ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석 (Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.