• 제목/요약/키워드: polymeric insulator

검색결과 61건 처리시간 0.021초

옥외용 절연체 표면에서의 ESDD 측정과 내오손특성에 관한 연구 (A Study on Measurement of ESDD and Contamination Performance of Polymeric Outdoor Insulators)

  • 연복희;유형철;이현진;송정용;이태호;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.427-430
    • /
    • 2002
  • This paper presents on contamination performance of polymeric outdoor insulator with different contaminant accumulation. The ESDD (equivalent salt deposit density), tracking resistance and clean-fog test were performed to investigate the characteristics of contamination performance on polymeric outdoor insulator. Furthermore, we evaluated together with the porcelain samples for its comparison. It is found that ESDD of polymeric and porcelain insulator depends on the installation position. This surface accumulation of contaminant lead to the loss of surface hydrophobicity, expecially upper shed part of polymeric insulator. In addition, the effect of an artificial contaminant on the tracking resistance by inclined-plane method and leakage suppression ability under clean fog was surveyed. The time of tracking failure did not appear to change significantly with a much contaminant accumulation, while leakage current under clean-fog increased.

  • PDF

지하철 고분자 지지애자의 설계 및 특성 평가 (Study on a design and characteristics tests of polymeric insulators for subway)

  • 한세원;조한구;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.514-517
    • /
    • 2003
  • Polymeric suspended insulators for subway and electrical track line had been designed and manufactured. The main elements to design polymeric insulators were the insulation ability and the optimal structure. To get the insulation ability, electrical and mechanical tests according to standards had done on housing rubbers and FRP cores and selected the sample with best properties as a insulator. The insulator shape and fitting parts with minimum electrical stress was simulated by FEM electrical field analysis program. The manufactured insulator set had been tested and estimated the electrical and mechanical according to ES and KS, and showed good characteristics in these tests.

  • PDF

초고압용 폴리머 애자의 산불영향 연구 (A study of the Influence of Forest Fire on Polymer Insulator for UHV)

  • 최인혁;최장현;정윤환;이동일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.254-259
    • /
    • 2005
  • Big fire such as mountain fire my cause the prevention of the functions of the overhead cables and insulators, which may affect the operation of the transmission lines. Therefore, in order to understand the effect of the mountain fire on the polymeric insulator for transmission lines, the author observed the deformation of the sheds of the polymeric insulators and the change of the discs of the porcelain insulators under fire, and investigated the electrical and mechanical characteristics of the insulators after the ignition test. As the result the following conclusions were obtained. First, the porcelain insulator was degraded in electrical characteristics when the insulator was subjected to the fire for approximately 5 minutes; whereas, the polymeric insulator was not degraded though there were some damage on its sheds. Second, after 20 minute exposure to the fire, the polymeric insulator lost a lot of parts of sheds, but the electrical characteristics was lowered by around 20%, but the porcelain insulators were electrically degraded by more than 80%.

  • PDF

산불영향에 따른 송전용 폴리머애자의 특성 (The Influence of Forest Fire on the Characteristics of Polymer Insulator for Transmission Lines)

  • 이동일;정용운;유근양;최인혁
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권3호
    • /
    • pp.127-131
    • /
    • 2005
  • Big fire such as mountain fire may cause the prevention of the functions of the overhead cables and insulators, which may affect the operation of the transmission lines. In the worst case, this kind of disaster may have a huge effect on the whole industry of a country. However, the study on the effect of the mountain fire on the transmission line is very rare. Therefore, in order to understand the effect of the mountain fire on the polymeric insulator for transmission lines, the author observed the deformation of the sheds of the polymeric insulators and the change of the discs of the porcelain insulators under fire, varying the ignition time using the artificial ignition testing equipment which simulates the mountain fire, and investigated the electrical and mechanical characteristics of the insulators after the ignition test. For the test, the miniature insulators made of polymeric material and porcelain have been utilized. As the result, the following conclusions were obtained. First, the porcelain insulator was degraded in electrical characteristics when the insulator was subjected to the fire for approximately 5 minutes; whereas, the polymeric insulator was not degraded though there were some damage on its sheds. Second, after 20 minute exposure to the fire, the polymeric insulator lost a lot of parts of sheds, but the electrical characteristics was lowered by around $20\%$, but the porcelain insulators were electrically degraded by more than $80\%$.

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

송전용 애자의 산불영향에 따른 특성 연구 (A study of the forest Fire Influence on the Insulator Characteristics for T/L)

  • 최인혁;최장현;이동일;정용운;유근양
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.138-144
    • /
    • 2005
  • 본 논문에서는 산불이 송전용 폴리머애자에 미치는 영향을 연구하기 위해 인공화염 시험장치를 제작하여 화염의 가열 시간에 따른 폴리머애자의 갓(shed) 변화와 자기애자의 disc 변화를 관찰하고, 전기적$\cdot$기계적 실험을 통하여 특성변화를 확인하였다. 실험결과 다음과 같은 결론을 얻을 수 있었다. 첫째, 화염의 가열시간이 5분정도 경과하였을 때, 자기애자의 전기적 특성은 $80(\%)$ 정도 저하된 반면에 폴리머애자의 경우 갓 유실이 있었지만 전기적 특성의 변화는 $10(\%)$ 정도였다. 폴리머애자를 20분 가열하였을 때는 대부분의 갓이 유실되었지만 전기적 특성치는 $20(\%)$ 정도 감소하였다. 둘째, 폴리머애자와 자기애자 모두 전기적 특성치의 감소는 있었지만 기계적 특성치는 양호하게 나타났다.

Capacitance-Voltage Characteristics of MIS Capacitors Using Polymeric Insulators

  • Park, Jae-Hoon;Choi, Jong-Sun
    • Journal of Information Display
    • /
    • 제9권2호
    • /
    • pp.1-4
    • /
    • 2008
  • In this study, we investigate the capacitance-voltage (C-V) characteristics of metal-insulator-semiconductor (MIS) capacitors consisting of pentacene, as an organic semiconductor, and polymeric insulators such as poly(4-vinylphenol) (PVP) orpolystyrene (PS) prepared by spin-coating process, to analyze the interfacial characteristics between pentacene and polymeric insulators. Compared with the device with PS, the MIS capacitor with PVP exhibited a pronounced shift in the flat-band voltage according to the bias sweep direction. This hysteric feature in the C-V characteristics is thought to be attributed to the trapped charges at the interface between pentacene and PVP owing to the hydrophilicity of PVP. From the experimental results, we can conclude that surface polarity of polymeric insulator has a critical effect on the interfacial properties, thereby affecting the bias stability of organic thin-film transistors.

고분자 애자 하우징용 HTV 실리콘 고무의 자외선 조사에 따른 표면열화 (Surface Degradation of HTV silicone Rubber used for a Polymeric Insulator by UV Irradiation)

  • 연복희;이상용;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.173-176
    • /
    • 2000
  • In this paper, we investigated the surface degradation of HTV silicone rubber used for a polymeric insulator by UV irradiation. To study the surface ageing properties by W irradiation, we used the corona discharge charging and contact angle. Therefore, we observed the change of surface charge retention and decrease of surface hydrophobicity. Also, we discussed the chemical change in the surface range using the analytic equipment such as SEM, ATR-FTIR, ESCA. Therefore, it is found that the scissor of characteristic bonding and the reattachment of oxidant bonding was developed by UV rays radiation. As discussing the corona ischarge charging and the change of contact angle, it is found the effect of UV irradiation and the mechanism of chemical reaction

  • PDF

고분자 피뢰기의 기밀특성에 관한 연구 (Sealing Integrity of polymeric ZnO Surge Arresters)

  • Liang, He-Jin;Han, Se-Won;Cho, Han-Goo;Kim, In-Sung
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.258-261
    • /
    • 1997
  • The sealing integrity is related to the safe operation of arrester the prime failure reason of porcelain housed arresters is moisture ingress. To be a meaningful tests a polymer arrester sealing test must be a realistic acceleration of field service. We think the test should be an accelerating course of actual temperatures, the enduring property to mechanical load and temperatures should be considered together. A union test method consisting of the thermal mechanical test and thermal cycling test is proposed to test the sealing integrity of polymeric arresters, which uses dielectric loss, leakage current 1mA DC voltage and partial discharge as the diagnostic techniques, and the test results were presented. The comparison states that the TMTCUT method is suitable fur the test of sealing integrity of polymeric arresters. .

  • PDF

Effects of Self-assembled Monolayer on PVP Gate Insulator for Organic Thin Film Transistors

  • Jang, Sun-Pil;Park, J.H.;Choi, J.S.;Ko, K.Y.;Sung, M.M.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.1044-1045
    • /
    • 2004
  • In this work, the characteristics of organic thin film transistors (OTFTs) with self-assembled monolayers (SAMs) on polymeric gate insulator have been investigated. The SAMs were formed using atomic layer deposition (ALD) method onto gate insulator. Upon the investigations, it was observed that SAMs modify the wettability of polymeric insulator and influence the growth of subsequent organic semiconductor, and thereby, electric conductivity and roughness of the pentacene film are improved.

  • PDF